Electromagnetic Compatibility (EMC) 

 

 

 

 

Patient Instructions 

Keep the following points in mind to secure a safe and smooth operation of the device: 

During  each  measurement  stay  relaxed  and  minimize  your  motion  to  keep  the  cuff  inflation  time  as  short  as 

possible. If you are relaxed the pressure load to your arm will be minimized. 

The trial measurement shows you the expected pressure load to your arm  during the long term measurement. The 

pressure load to your arm will vary over the whole day. If the pressure rises far above the expected pressure, you are 

allowed to deflate the cuff by pressing the           button or just remove the cuff from your arm. 

Please note down all important events in a diary to secure a correct interpretation of your blood pressure values by 

the doctor. Please report all unexpected events or faults to your doctor. 

Do  not  open  the  battery  compartment.  Protect  the  device  against  water,  excessive  humidity,  and  extreme 

temperatures and do not remove the device from the wearable pouch. Please wear the pouch over your clothes. You 

do  not  have  to  clean  the device  after the  long  term  measurement.  Sometimes  the  device internally  stops  the long 

term measurement. In this case deliver the device to the agreed date to your doctor. 

The audio signals of the device are disabled by default. If the doctor enables the audio signals, the device will beep 

after power up procedure and in front of every measurement during day phase. 

Place PHYSIO-PORT UP with the wearable pouch on your nightstand while you are sleeping. You are allowed to 

change  the  day  phase  and  the  night  phase  manually,  if  you  go  to  bed  before  10 pm  or  get  up  before  7 am.  To 

change the phases press the            button once. The results from the last blood pressure measurement are shown. 

Press the          button once again, while the results are shown. The phase symbol switches from sun to moon or the 

other way around. 

For your interest

The device measures your systolic, diastolic and mean arterial blood pressure and your heartrate. The blood pressure 

is measured with an accuracy of ± 3 mmHg. The device can record up to 400 blood pressure measurements. 

 

Note down here the additional instructions of your doctor: 

 

 

 

Summary of Contents for PHYSIO-PORT UP

Page 1: ...PHYSIO PORT UP Ambulatory Blood Pressure System Firmware Version 3 0 Operator s Manual A9951 ENG Revision C...

Page 2: ...anual only applies to PHYSIO PORT UP firmware version 3 0 It does not apply to earlier firmware versions Due to continuing product innovation specifications in this manual are subject to change withou...

Page 3: ...romagnetic Compatibility EMC 29 Revision History This manual is subject to the GE Healthcare change order service The revision code a letter that follows the document part number changes with every up...

Page 4: ...ecified in CISPR11 EN 55011 class B The CE marking covers only the accessories listed in the Order Information chapter This manual is an integral part of the equipment It should be available to the eq...

Page 5: ...General Information 5 PHYSIO PORT UP A9951 Revision C PAR Medizintechnik GmbH Co KG Rigistr 11 12277 Berlin Germany Tel 49 30 235 07 00 The country of manufacture is indicated on the device label...

Page 6: ...g a novel and faster technology already during inflation of the cuff inflation measurement method The deflation measurement method is the most com mon method used With this technique the cuff is infla...

Page 7: ...g diastolic pressure at 83 mmHg With both methods a pressure transducer measures the cuff pressure as well as the superimposed pressure pulsations During blood pressure measurements the cuff must be a...

Page 8: ...erators or third parties The responsible organization should identify analyze evaluate and control these risks Changes to the IT network could introduce new risks that require additional analysis Chan...

Page 9: ...s they may emit higher levels of electromagnetic radiation Caution Equipment damage risk to persons Before connecting the battery charger to the power line check that the voltage ratings on the namepl...

Page 10: ...ment method deflation measurement method or inflation measurement method 1 Button push to display the most recent para meter readings The display will show systolic value S unit mmHg or kPa shown on t...

Page 11: ...water No protection against contact and ingress of objects and protection against dripping water when tilted at 15 Keep dry Temperature limits Humidity limits Air pressure limits USB port connection...

Page 12: ...e replaced by a service technician The capacity of two fully charged or new batteries is sufficient for up to 48 h of operation or 400 blood pressure measurements The capacity of rechargeable batterie...

Page 13: ...compartment and close Charging NiMH Batteries If PHYSIO PORT UP is powered by rechargeable batteries 4 of them are shipped with the equipment they should be recharged immediately after use 24 hours Us...

Page 14: ...N Insert charged batteries OR briefly press To switch OFF Remove the batteries or press for 3 seconds Performance Check When turned on PHYSIO PORT UP runs a self test that includes all symbols and seg...

Page 15: ...layed Push the display indicates H 1 Push the display indicates LLLL To delete the data push again the display indicates 0000 followed by the time if you do not wish to clear the memory turn off the B...

Page 16: ...nfirm with or switch to the other option with then confirm with Measurement Protocols There is a choice of three different measurement protocols Protocol Day Phase 7 a m to 10 p m Night Phase 10 p m t...

Page 17: ...cuff pressure due to connection tubing kinking Too frequent measurements can cause injury to the patient due to blood flow interference The application of the cuff over a wound can cause further injur...

Page 18: ...of PHYSIO PORT UP 2 Fig 2 1 Do not wrap the pressure tubing completely around the neck to avoid strangulation of the patient You must hear the connector click into place Ensure that the tube is not ki...

Page 19: ...rable pouch to remove the pressure hose only in emergency situations see warning below that the cleaning may only be carried out by qualified medical personnel and not by the patient Absolute Contrain...

Page 20: ...consecutive unsuccessful measurements Error codes E02 battery depleted E06 inflation time over and E08 maximum number of pressure measurements taken 200 or 400 do not lead to a second measurement The...

Page 21: ...on PHYSIO PORT UP and wait for the time to be displayed For more information about data output please refer to the Operator s Manual of PhysioPortWin When you have finished downloading data to Physio...

Page 22: ...d be identified PHYSIO PORT UP does not measure diastolic pressures below 40 mmHg E 15 Motion artifact during diastole detection E 17 Internal hardware error Please contact your local authorized deale...

Page 23: ...B 1 1 2 0 or 3 0 7 3 USB Driver You will need administrator privileges for installation 1 Turn on the PC and the monitor Exit ALL programs 2 Insert the storage device USB stick with the USB driver If...

Page 24: ...If a USB serial port greater than COM4 has been selected one of the ports COM1 through COM4 must be disabled at the PC so that it can be assigned to the USB port 3 Select one of the ports COM1 throug...

Page 25: ...aton rapid Sporicidin or Cidex After disinfection rinse the cuff thoroughly with tap water and air dry Moreover spray disinfection has proved successful after the usage of the cuff Incidin Foam or equ...

Page 26: ...Please contact an authorized representative of the manufacturer for information concerning the decommissioning of your equipment The cuffs can be disposed as contaminated hospital waste Calibration Mo...

Page 27: ...suring Method Oscillometric selectable measurement method deflation measurement method or inflation measurement method Battery Charger protection class II IP20 100 to 240 VAC 50 60 Hz 0 5 A Ambient Co...

Page 28: ...A867 Connection cable PHYSIO PORT UP to PC USB length approx 1 5 meters S2010 Connection cable PHYSIO PORT UP to PC RS232 length approx 1 2 meters A20931 Battery charger with USB connection cable and...

Page 29: ...RF emissions to EN 55011 CISPR 11 Group 1 PHYSIO PORT UP uses RF energy only for their internal function Therefore their RF emissions are very low and are not likely to cause any interference in near...

Page 30: ...cal commercial or hospital environment Surge to EN 61000 4 5 IEC 61000 4 5 0 5 kV differential mode 1 0 kV differential mode 0 5 kV common mode 1 0 kV common mode 2 0 kV common mode not applicable not...

Page 31: ...and d is the recommended separation distance in meters m Field strengths from fixed RF transmitters as determined by an electro magnetic site surveya should be less than the compliance level in each f...

Page 32: ...mum Output Power of Transmitter W Separation Distance According to Frequency of Transmitter m 150 kHz to 80 MHz d 1 17 P 80 MHz to 800 MHz d 1 17 P 800 MHz to 2 7 GHz d 2 33 P 0 01 0 12 0 12 0 24 0 1...

Page 33: ...the device from the wearable pouch Please wear the pouch over your clothes You do not have to clean the device after the long term measurement Sometimes the device internally stops the long term measu...

Page 34: ...iew 27 Functional Description 8 G General Information 5 I Indicators 11 Inflation measurement 7 Inflation Measurement Method 21 Inflation Measurement Technology 7 Information for patients 20 Intended...

Page 35: ...51 Revision C T Technical Inspections of the Measuring System 27 Technical Safety Inspections 27 Time set 17 Toggling Between Day and Night Phase 21 Trial Measurement 19 U USB Driver installation 24 W...

Page 36: ...36 PHYSIO PORT UP A9951 Revision C Index PAR Medizintechnik GmbH Co KG Rigistr 11 12277 Berlin Germany Tel 49 30 2350700 www par berlin com Printed in Germany...

Reviews: