background image

Important Information

Q Brass range

Prior to Installation:

Water Pressure & Temperature:

Note:

  In areas where the recommended maximum water pressure is exceeded, pressure-limiting 

valves must be installed by a licensed plumber.

Maximum Water Temperature
Maximum Water Pressure
Regulatory Maxumim Water Pressure

80° Celcius
1600kPa
500kPa

This Par Taps products are to be installed by a Licensed Plumber in accordance with AS/NZS 3500.1

•  Please read these instructions completely.
•  All instructions serve as a guide only and must be installed by a licensed plumber.  Installation 

carried out by unlicensed individuals will void all warranties.

•  Ensure water supply lines are closed.
•  Supply lines must be flushed prior to installation to remove any foreign matter.
•  All products are suitable for use with most instantaneous hot water heaters, however are not 

compatible with gravity-fed water systems.

WALL SET ON PLATE

TOP ASSEMBLYS

3 PIECE SET

200mm OUTLET

WALL SET ON PLATE - OFFSET

Summary of Contents for Q/IDK Series

Page 1: ...Q IDK Collection Installation Guide Thank you for purchasing this Par Taps product designed and built in australia Ver 20 2 ...

Page 2: ...censed Plumber in accordance with AS NZS 3500 1 Please read these instructions completely All instructions serve as a guide only and must be installed by a licensed plumber Installation carried out by unlicensed individuals will void all warranties Ensure water supply lines are closed Supply lines must be flushed prior to installation to remove any foreign matter All products are suitable for use ...

Page 3: ...hould be fitted to turn open towards the outlet thus preventing potential accidents such as scolding Please Note For correct fitment it is essential that there is a 55 65mm space between the face of the noggin and wall surface If this space is exceeded longer spindle extensions will need to be fitted Min 55mm Max 65mm ...

Page 4: ...make sure the seat surface is clean and smooth otherwise reseat and recheck Also ensure that lines have been flushed Ensure that the hot and cold indicators located on the bottom of the Ceramic Disc Assembly 3 are placed in the corresponding side of the breach Insert ceramic disc assembly 3 into Wall breech Tighten ceramic disc assembly 3 firmly using a 14mm Deep tube socket not supplied Then place ...

Page 5: ...ackplate 5 to wall surface Please ensue that the backplate is level before tightening 3 5 Slide the Backplate 5 over the ceramic disc assembly 3 onto the finished wall Firmly push the handle 7 to the main body Fig E Tighten the grub screw 9 to secure 4 6 Please Note In the diagrams above Fig D Fig E for clarity the tile wall face has not been depicted Fig C 5 6 8 9 7 Backplate 5 Dome 6 Handle Outl...

Page 6: ...seat surface is clean and smooth otherwise reseat and recheck Also ensure that lines have been flushed Ensure that the hot and cold indicators located on the bottom of the Ceramic Disc Assembly 3 are placed in the corresponding side of the breach Fig A Insert ceramic disc assembly 3 into Wall breech Tighten ceramic disc assembly 3 firmly using a 14mm Deep tube socket not supplied Then place the fibre...

Page 7: ...ackplate 5 to wall surface Please ensue that the backplate is level before tightening 3 5 Slide the Backplate 5 over the ceramic disc assembly 3 onto the finished wall Firmly push the handle 7 to the main body Fig E Tighten the grub screw 9 to secure 4 6 Please Note In the diagrams above Fig D Fig E for clarity the tile wall face has not been depicted Fig C 5 6 8 9 7 Backplate 5 Dome 6 Handle Outle...

Page 8: ......

Reviews: