30
Operation
5.1.3
Connecting further SOL.Connect Devices
Details on how to connect and operate the optionally available SOL.Connect
devices are indicated in the quick guides included in the respective scope of
supply!
5.1.4
Connecting a large-scale display
5.1.4.1
Connecting a serial display (direct connection)
A serial display is connected directly to the data logger, following these steps:
•
Connect the large-scale display with pin A and A at the data logger’s
terminator strip (A = data+; B = data-).
Illustration 5-1 Connecting Display
•
Configure the display (see chapter 7.7.2.4)
The display receives data which are being displayed.
5.1.4.2
Connecting a remote display)
Via a serial Ethernet converter (RS485) a large-scale display which is availa-
ble via the internet can also receive data (UDP-communication). Some net-
work settings of the serial Ethernet converter within the data logger are nec-
essary (see chapter 7.7.2.4).
Data logger
network (internet)
serial ethernet converter
display