IDF Preparation and Mounting
3.
Stand up the IDF enclosure so that there is access to open the front door and center section. Open so that there
is access to the rear panel of the enclosure.
4.
Remove the Recommended Conduit Locations Template from the Lower Backplane (rolled up in the Tak-Ty).
Figure 5: Location of template in step 4:
5.
Tape the template to the bottom of the IDF enclosure. The bottom outside rear edge of the bend is indicated on
the template in
Figure 6: Recommended Conduit Location Template
6.
Using the template from step 4, mark the desired locations for the external conduit entry on the bottom of the
enclosure.
7.
Drill and punch all conduit entry positions that will be used in this installation.
8.
Following the Hoffman installation guide, mount the enclosure in the desired location using the 6 holes on the
wall section of the enclosure.
9.
Install all conduit connections in the appropriate locations.