3E: Service
•
Have your Fixture serviced by a qualified repair person using only identical replacement
parts.
Contact Panduit Electrical Products Division Service at the following locations:
Panduit Electrical Products Division
(USA)
16530 W. 163
rd
Street
Lockport, IL 60441
888-506-5400, ext. 83255
Panduit EMEA Service Center (EUR)
EMEA Tool Service Center
Bedrijvenpark Twente 360
7602 KL Almelo
tel + 31 546 580 451
This will ensure that the safety of the fixture is maintained.
The information contained in this manual is based on our experience to date and is believed to be reliable. It
is intended as a guide for use by persons having technical skill at their own discretion and risk. We do not
guarantee favorable results or assume any liability in connection with its use. Dimensions contained herein
are for reference purposes only. For specific dimensional requirements consult the factory. This publication is
not to be taken as a license to operate under, or a recommendation to infringe any existing patents.
4: TECHNICAL SPECIFICATIONS
4A: Air Supply
ITEM
DESCRIPTION
PATMFM4.0 Recommended regulated air pressure to
fixture. (pressures other than recommended may
result in unsatisfactory operation):
MIN.: 40 PSI (2,8 bar)
MAX: DO NOT EXCEED 45 PSI (3,1 bar).
Max. recommended pressure drop: 5PSI (0.34bar)
PATMFM4.0 Filter/regulator requirements:
•
40-micron maximum element rating
•
5 PSI (0,3 bar) maximum pressure drop @
45 PSIG (3,1 bar) inlet pressure
•
12 cfm (5,7 l/sec) flow minimum.
Lubrication for air supply:
Air-line lubricators are NOT to be used. Lubricators
will damage internal system components and seals.
PAT4.0 Recommended filter/regulator unit (supplied
by user) 3/8" NPT ports:
Recommended source:
Panduit Part Number PL283N1.