Panduit PATMFM4.0 Operation Manual Download Page 14

© Panduit Corp. 
2020 

 

OPERATION MANUAL 

PATMFM4.0 

                      ENGLISH

 

 

13 

 

  3E: Service

 

 

Have your Fixture serviced by a qualified repair person using only identical replacement 
parts. 

 

Contact Panduit Electrical Products Division Service at the following locations: 

Panduit Electrical Products Division 

(USA) 

16530 W. 163

rd

 Street 

Lockport, IL  60441 

 

888-506-5400, ext. 83255 

Panduit EMEA Service Center (EUR) 

EMEA Tool Service Center

 

Bedrijvenpark Twente 360

 

7602 KL Almelo 

 

tel + 31 546 580 451 

 

This will ensure that the safety of the fixture is maintained. 

 

 

The information contained in this manual is based on our experience to date and is believed to be reliable.  It 
is intended as a guide for use by persons having technical skill at their own discretion and risk.  We do not 
guarantee favorable results or assume any liability in connection with its use.  Dimensions contained herein 
are for reference purposes only. For specific dimensional requirements consult the factory. This publication is 
not to be taken as a license to operate under, or a recommendation to infringe any existing patents. 

 

 
4: TECHNICAL SPECIFICATIONS 

4A: Air Supply 

ITEM 

DESCRIPTION

 

PATMFM4.0 Recommended regulated air pressure to 

fixture. (pressures other than recommended may 

result in unsatisfactory operation): 

MIN.: 40 PSI (2,8 bar)  
MAX: DO NOT EXCEED 45 PSI (3,1 bar). 
Max. recommended pressure drop: 5PSI (0.34bar) 

 

PATMFM4.0 Filter/regulator requirements: 

 

40-micron maximum element rating 

 

 5 PSI (0,3 bar) maximum pressure drop @ 
45 PSIG (3,1 bar) inlet pressure 

 

12 cfm (5,7 l/sec) flow minimum.  

Lubrication for air supply: 

Air-line lubricators are NOT to be used. Lubricators 
will damage internal system components and seals. 

PAT4.0 Recommended filter/regulator unit (supplied 

by user) 3/8" NPT ports: 

Recommended source: 
Panduit Part Number PL283N1. 

 

Summary of Contents for PATMFM4.0

Page 1: ...instructions for the following PATMFM4 0 WARNING TO REDUCE THE RISK OF INJURY USER MUST READ INSTRUCTION MANUAL Email techsupport panduit com EU Website www panduit com emea EU Email emeatoolservicec...

Page 2: ...ator 8 3 GENERAL POWER TOOL SAFETY WARNINGS 9 3A Work Area Safety 9 3B Operational Safety Practices 11 3C Personal Safety 11 3D Power Tool Use and Care 12 3E Service 13 4 TECHNICAL SPECIFICATIONS 13 4...

Page 3: ...ATION 25 6A Start Up Checklist 25 6B Cable Tie Installation 25 6C Tip Deflector Waste Receptacle 29 7 MAINTENANCE 30 7A Preventative Maintenance 30 8 TROUBLESHOOTING 31 8A Error Message Troubleshootin...

Page 4: ...Bench Mount Fixture consists of seven individual units The Table Top Fixture Fixture Tool Cage EI Communication Cable Tip Deflector Tool Cavity Cover Table Top Template and the PATMFM4 0 Air Regulator...

Page 5: ...ower Tool Support Item C via the two thumbscrews Item D With the Rear Support removed a Hand Tool can be inserted and aligned relative to the Top and Bottom Front Tool Supports Item s A B Once a selec...

Page 6: ...th Max excluding airline 4 63 118mm Width Max 4 16 106mm Height Max 6 28 160mm 2C EI Communication Cable The EI Communication Cable routes power and data between the PAT4 0 System and the PATMFM4 0 Fi...

Page 7: ...collect scrap from multiple jobs cycles without constant removal and clean up Tip Deflector General Overview Table 2D Tip Deflector Overall Specification Dimension Value Length 3 58 91mm Width 2 09 53...

Page 8: ...r the Fixture A perimeter pattern of eight 8 total through holes and an aligned rectangular pocket must be drilled and routed respectively in order to install the PATMFM4 0 Fixture successfully A prop...

Page 9: ...rating pressure utilized by the PATMFM4 0 Fixture The PATMFM4 0 Air Regulator is adjustable and should be set to the recommended output specification Table 4A before connecting to and operating the Fi...

Page 10: ...r battery operated cordless power tool Panduit Corp recommends the fixture be used with all installed safety features Customer assumes all liability for injury that could result from improper use of t...

Page 11: ...f electric shock WARNING ONLY OPERATE THE PATMFM4 0 SYSTEM IN A CLEAN DRY INDOOR ENVIRONMENT DO NOT EXPOSE POWER TOOLS TO RAIN OR WET CONDITIONS Water entering a power tool will increase the risk of e...

Page 12: ...between the jaws of the tool 2 DO NOT operate the tool with the rear jaw held open Cable ties may be ejected from the tool at high velocities 3 DO NOT operate the tool near anyone s face 4 DO NOT oper...

Page 13: ...for which it was designed 2 Do not use the power tool if the switch does not turn it on and off Any power tool that cannot be controlled with the switch is dangerous and must be repaired 3 Disconnect...

Page 14: ...e any liability in connection with its use Dimensions contained herein are for reference purposes only For specific dimensional requirements consult the factory This publication is not to be taken as...

Page 15: ...ne on the template denotes the minimum distance relative to the leading edge as required by the fixture Once the template is aligned appropriately secure the sheet at each corner and ensure the templa...

Page 16: ...sembly 3 Insert the PAT1M4 0 or PAT1 5M4 0 into the Tool Cage ensuring that the Tool properly aligns within the Front Upper and Lower Tool Supports Proper installation can be verified by ensuring the...

Page 17: ...ng 1 REMOVE x2 REAR THUMBSCREWS 2 REMOVE REAR LOWER TOOL SUPPORT 3 INSTALL PAT1M4 0 PAT1 5M4 0 TOOL INTO UPPER AND LOWER FRONT TOOL SUPPORTS 4 REINSTALL REAR LOWER SUPPORT AND THUMBSCREWS 5 HAND TIGHT...

Page 18: ...ool Cage will not shift or release from the Fixture Assembly unless guided back and out of the tracks 2 For aiding installation releasing the Actuation Paddle with the PAT4 0 switched off will reveal...

Page 19: ...Cage against Guiding Edge s TRACKS GUIDING EDGE THE TOOL CAGE IS INSTALLED FROM THE UNDERSIDE OF THE PATMFM4 0 FIXTURE USE THE GUIDING EDGES TO ALIGN AND ENGAGE THE TOOL CAGE TRACKS FOLLOW ALONG THE...

Page 20: ...rly Guided and Retained Within Fixture Tracks REAR TRACK EDGE S TOOL CAGE SHOULDER SCREWS ALIGNED WITH START OF TRACKS FOLLOW TRACK PATTERN UNTIL REAR TRACK EDGES ARE REACHED TOOL CAGE SHOULDER SCREWS...

Page 21: ...latch the Actuation Paddle into the operational orientation Tool Cage Airline to Fixture Insertion WITH THE PAT4 0 DISPENSER OFF AND THE ACTUATION PADDLE IN THE VERTICAL POSITION THE REAR RIGHT TRACK...

Page 22: ...f begin by connecting one end of the EI Communication Cable into the PAT4 0 s corresponding connector located on the rear of the Dispenser Use a Philips head screwdriver to retain this connection Conn...

Page 23: ...PAT4 0 air supply s quick connect fitting insert the PATMFM4 0 Air Regulator s corresponding fitting Install the PATMFM4 0 Air Regulator onto the PAT4 0 system The PATMFM4 0 Air Regulator branches the...

Page 24: ...Hose s in the same manner as the standalone Hand Tools Refer to the PAT4 0 manual and follow the hose routing guidelines to ensure proper installation Confirm that the placement of the PAT4 0 Dispens...

Page 25: ...to the PAT1M4 0 or PAT1 5M4 0 Hand Tool mounted within the Tool Cage Hold the Tool Cage and or mounted Hand Tool secure whilst connecting the PHM Hose to ensure a proper connection Note The PHM Hose...

Page 26: ...ply quick connect fitting 10 Is the PHM Feeder Hose securely connected to the PAT1M4 0 or PAT1 5M4 0 Tool and PAT4 0 Dispenser 11 Is there a waste receptacle placed underneath and behind the Tip Defle...

Page 27: ...ght hand altogether or with the workpiece itself The paddle does not need to be held in the actuation position during a cycle A simple yet deliberate tap is all that is required to initiate and comple...

Page 28: ...dge of this slot as shown below to align the workpiece properly Work Bundle Aligned for Tie Installation 6 Once the workpiece is properly aligned relative to the measurement scale s move both hands si...

Page 29: ...on by pressing on the paddle until it is lying flat relative to the fixture The spring loaded latch will briefly retract and then engage with the paddle holding it in this position Setting Actuation P...

Page 30: ...wards the back of the cover will pitch the front end upwards for ease of removal Tool Cavity Cover Installation and Removal 6C Tip Deflector Waste Receptacle The PATMFM4 0 Fixture includes a Tip Defle...

Page 31: ...aste Receptacle Orientation 7 MAINTENANCE 7A Preventative Maintenance Interval Maintenance Procedure Every 100 000 cycles A Remove the PAT1M4 0 or PAT1 5M4 0 Hand Tool and clean debris if any from bot...

Page 32: ...s present between these two connections B 1 Check to ensure that the PATMFM4 0 Air Regulator is properly connected to both the PAT4 0 Air Regulator and the PATMFM4 0 Pg 22 Cycle does not begin Air is...

Page 33: ...Length x2 9A WA29568E01 Overlay Plate Assembly PART ID PART NAME DESCRIPTION QTY 1 WA29515E01 OVERLAY PLATE 1 2 WA29527D01 INSERT PLATE 1 3 CA29554B01 COMP SPRING 0 5 L 0 12 OD 096 ID 1 4 WA29517C01 P...

Page 34: ...T 1 6 WA29566C01 ACTUATOR ASSEMBLY 1 7 CA29546B01 PLASTIC HEAD THUMB SCREW 1 4 2 TH 2 LENGTH 2 8 CA29550B01 STEEL SHOULDER SCREW 5 32 SH DIA 1 8 SH LENGTH 6 32 TH 4 9 CA29547B01 TORX ROUNDED HEAD THRE...

Page 35: ...1 5 CA29555B01 STEEL NYLON INSERT LOCKNUT 5 40 TH 2 6 CAT 05063A PC FITTING BARBED 10 32 TH TO 1 4 HOSE 2 7 CAT 05353A PC GASKET 3 8 CAT 05065A PC FITTING ADJUSTABLE L 1 9 CA29549B01 BUTTON HEAD HEX S...

Page 36: ...1 7 CAT 12179A PC CLAMP HOSE 2 8 CAT 07504A PC 1 4 COUPLER 1 4 NPTF FEMALE 1 9 CAT 10388A PC PLUG PIPE HEX 1 8 NPT 1 10 PTS 07574B MX HOSE OVERBRAIDED URETHANE PER FOOT 6 11 CA29718A01 GAGE WITH 1 8 2...

Reviews: