For Technical Support: www.panduit.com/resources/install_maintain.asp
INSTALLATION INSTRUCTIONS
© Panduit Corp. 2014
FS069
Page 7 of 12
1.2
Remove the dust cap from the metal end
(rear) of the inner housing assembly. Place
the inner housing assembly onto the .100"
hex crimp pocket (die size numbers are on
crimp die on the opposite side) of the
FCRP5 crimp tool. Locate the inner housing
assembly so that the crimp die pocket
passes through the crimp thru window and
onto the ferrule assembly. When loaded, the
“SC” lettering on the crimp die should
straddle the ferrule holder.
1.3
Partially close the tool to contain the inner
housing assembly.
DO NOT CRIMP THE
FERRULE HOLDER.
1.
LOADING INNER HOUSING ASSEMBLY INTO FCRP5 CRIMP TOOL
1.1
IMPORTANT: TOOL MUST HAVE A “P” ON THE
LOWER CRIMP DIE (SEE FIGURE 1.1), IF NOT,
PLEASE CONTACT TECHNICAL SUPPORT.
Pull
ferrule assembly retainer clip away from tool and rotate
the clip until the “SC” lettering on the crimp die is visible.
Release clip.
Note:
Some clips have a small bump on one side. If
there is a bump on the clip, be sure to align the clip so
that when the “SC” lettering is visible, the bump is facing
away from the crimp dies and the “FJ” lettering is
pointing towards the handle of the tool.
Jacketed Cable Termination
1.1
Bump
SC
lettering
1.3
Tool
Gap
Inner
Housing
Assembly
Ferrule holder
Crimp die
Crimp Thru
Window
Ferrule holder
Retainer clip
1.2