PDU INSTALLATION MANUAL

 

Panduit Monitored & Switched per Outlet PDU: 

Provides outlet-level power 

monitoring and outlet-level switching capabilities for individual outlets or a group of 

outlets. Power monitoring at the individual outlet level provides actionable 
management data on the power consumption of each connected IT device, 
enabling the redeployment or decommissioning of individual servers to 
reclaim available or under- utilized power capacity. 

Features

 

The Panduit Monitored, Switched, Monitored per Outlet, and Monitored & 

Switched PDUs provide the following features: 

Lower profile on Vertical PDUs 

– enhances serviceability area in the

back of the  rack.

Multiple mounting options on Vertical PDUs 

– can be mounted with

outlets facing in toward center of rack, back or front of rack.

Higher operating temperature 

– all Essential series PDUs rated for 

60˚C

operating temperature.

Color-coded outlets to circuit breakers 

– used to easily differentiate

load segments and phases

1U PDUs support multiple mounting options 

– can be mounted

horizontal in a U space or in the True 0U space between the RETMA rails.

Hot Swappable Network Management Module 

– allows power

distribution during module replacement eliminating downtime.

10/100 Ethernet 

– eliminates the need to manually set the network switch

to run at a slower  rate

Daisy Chain 

– able to network up to sixteen of the same PDUs on one IP

address.

Enhanced Sensor Support 

– supports up to 2 physical sensors and four

measurements per PDU with a total of 128 measurements in a maximum
daisy chain configuration.

Highly Visible LCD display 

– improves visibility while providing local

access to view configuration setting. Automatically enters sleep mode to
conserve energy and protect the display from burn in.

Summary of Contents for ES2P

Page 1: ...ES2P Intelligent PDU Installation Manual V1 1...

Page 2: ...nt and Phase Distinction 8 Section 2 Installing the PDU 9 Vertical PDUs 9 Install Mounting Hardware 9 Install Bracket Hardware BRK01 Optional 10 Vertical 0U PDU Single Installation 11 Vertical 0U PDU...

Page 3: ...ipment ITE loads with linear Power Factor Corrected PFC input current If non linear loads are connected the nameplate current rating of the PDU must be reduced by a factor of 0 8 WARNING A risk of per...

Page 4: ...f fire or electric shock install this PDU in a temperature and humidity controlled indoor environment free of conductive contaminants Do not operate near water or excessive humidity 90 maximum noncond...

Page 5: ...5 ES2P PDU INSTALLATION MANUAL Required Tools The following tools maybe required for installation Phillips screwdriver Torx screwdriver...

Page 6: ...the local display Panduit PDUs are designed for use with all Panduit cabinets and are compatible with most third party data center racks The PDU models vary in form factor with several mounting confi...

Page 7: ...r front of rack Higher operating temperature all Essential series PDUs rated for 60 C operating temperature Color coded outlets to circuit breakers used to easily differentiate load segments andphases...

Page 8: ...n the rack or in the true 0U space on the side of the rack between the RETMA rails Load Segment and Phase Distinction Panduit Essential PDUs have colored receptacles to help distinguish between the di...

Page 9: ...two mounting hole locations on the back of the PDU for the button installation to assist with mounting in a non Panduit racks When installing the mounting buttons use either mounting hole as a set Mo...

Page 10: ...dition for installing the mounting buttons Bracket Installation Outlets Facing the Center of the Rack Each vertical PDU can install the optional bracket with provided screws on the end of the PDU 1 Al...

Page 11: ...the rack Vertical 0U PDU Two or More Installation For two full height in a 42U 45U 48U rack two mid height in a 42U 45U 48U rack or four half height in a 42U 45U 48U rack vertical units to be mounted...

Page 12: ...Mounting Hardware Installation 1U PDU Mounting in a U Position of the Rack 1 Install the cage nuts at the desired U location 2 Screw the mounting bracket ears into the RETMA rail surface at the U loca...

Page 13: ...ground bonding cable if the rack contains any conductors for functional grounding or bonding of ungrounded metal parts This bonding point can also be used to bond the PDU to a known earthed reference...

Page 14: ...ins an external earthing screw with a star washer which should be used for supplementary Earth bonding to the rack metalwork Bonding Minimum Requirements for Bonding Conductors Up to and including 32A...

Page 15: ...h in the PDU power cord to reach the PDU power source 1 Turn the feed circuit breaker Off 2 Make sure that all circuit breakers on the PDU are set to On 3 Connect each PDU to an appropriately rated br...