Panduit CTFP-40 Operating Instructions Manual Download Page 4

© Panduit Corp. 2019 

OPERATING INSTRUCTIONS 

CTFP-40 

ENGLISH 

 

PA29443A01_02_ENG   

 

 

Page: 3 of 8 

 

 

 

 

3-2019

 

 

1.5 ....... Sources of danger 

The CTFP-40 must only be operated when the finger guard is screwed on. Only filtered compressed 
air with a maximum pressure of 6 bar can be used. 
 
Disconnect the machine from the compressed air before working on the CTFP-40, during breaks and 
when the device is not in use. Do 

not 

pull on the compressed air tubing to disconnect. 

 

1.6 ....... Work places 

The following should be avoided for operation and storage: 

  damp or dusty places,

 

  places which are subject to high levels of heat, direct sunlight or low temperatures: 

operating range: 59°F to 95°F (15 °C to 35 °C).

 

 

Protect the compressed air tubing from heat, oil and sharp edges. 

 

1.7 ....... Safety devices 

The CTFP-40 has a finger guard at the front as a contact safety device. 

Under no circumstances should this be removed. 

The CTFP-40 is stopped when disconnected from the compressed air supply. 

 

1.8 ....... Permitted operators 

Only authorized and instructed operators can work on the CTFP-40. The operator is responsible to 
third parties in the working area. 
 
The owner must: 

 

make the operating instructions available to the operator and 

 

make sure that the operator has read and understood the instructions 

 

1.9 ....... Guarantee 

In principle, our "General terms of purchase and delivery" apply. These are available to the owner 
when the contract is concluded at the latest. 

Guarantee and liability claims resulting from damage to personnel or property are inadmissible if the 
following points have been violated: 

  Non-designated use of the CTFP-40. 

  Inappropriate working places. 

  Inappropriate use and use which goes beyond that described in the operating instructions. 

  Unauthorized structural amendments to the CTFP-40. 

  Continued use of the CTFP-40 when a malfunction has been established. 

  Repairs carried out inappropriately. 

 

!

 

Only use original spare parts 

 

Summary of Contents for CTFP-40

Page 1: ...e Panduit products are continually being improved and updated Consequently pictures may vary from the enclosed product For the most current version of this instruction manual go to www panduit com Ema...

Page 2: ...ness of the machine 2 1 4 Designated use 2 1 5 Sources of danger 3 1 6 Work places 3 1 7 Safety devices 3 1 8 Permitted operators 3 1 9 Guarantee 3 2 DESCRIPTION 4 2 1 Application 4 2 2 Components 4 2...

Page 3: ...o recognized technical safety regulations and has undergone a safety examination and received official acceptance It is equipped with safety devices However operating error and misuse could present a...

Page 4: ...mstances should this be removed The CTFP 40 is stopped when disconnected from the compressed air supply 1 8 Permitted operators Only authorized and instructed operators can work on the CTFP 40 The ope...

Page 5: ...G 0 25 and 4 0 mm The CTFP 40 comprises a tabletop unit and a foot operated switch As both hands are free to insert the wire fitted with wire end ferrules the CTFP 40 is ideally suited to pre confecti...

Page 6: ...sert the table clamp 4 into the bore hole in the tabletop unit and screw tightly to the worktable Check the compressed air supply min 4 bar max 6 bar filtered air Connect the free connection 5 on the...

Page 7: ...crew hexagon socket screw 1 Pull out the die set 2 Clean die set 3 and lightly oil pivot 4 Push in die set 5 Tighten hexagon socket screw 6 Figure 4 Cleaning 4 2 Lubrication Unscrew the head 1 Remove...

Page 8: ...e ordered with the appropriate Article No Figure 6 Spare parts No Part Article No No Part Article No 1 Compressed air tube 008137 8 Head part incl screw and seal 009691 2 Body 001564 9 Axis 001569 3 A...

Page 9: ...ion min 4 bar max 6 bar Air consumption 0 2 liter Crimping at 5 bar Dimensions diameter x length x height 7 8 x 5 3 x 2 9 200 x 135 x 75 mm Weight approx 6 2 lbs 2 8 kg Acoustic pressure emissions LpA...

Page 10: ......

Page 11: ...es mises jour pour maintenir les plus hauts standards et a la fine pointe de la technologie Par cons quent les illustrations peuvent tre diff rentes du produit fourni REMARQUE Des versions mises jour...

Page 12: ...ndications d utilisation 2 1 5 Sources de danger 3 1 6 Lieu de travail 3 1 7 Equipements de protection 3 1 8 Utilisateur autoris 3 1 9 Garantie 3 2 DESCRIPTION 4 2 1 Utilisation 4 2 2 Composants 4 2 3...

Page 13: ...form ment aux dispositions techniques de s curit en usage et a subi des tests et un contr le de s curit Elle est quip e de dispositifs de s curit Pourtant en cas de fautes lors de l utilisation ou d u...

Page 14: ...otection L CTFP 40 a sur sa face avant une anse de protection des doigts pour prot ger des contacts ventuels Elle ne doit tre en aucun cas loign e de la machine L CTFP 40 est mise automatiquement hors...

Page 15: ...ant de 0 25 4 mm Il se compose d un appareil mobile de table et d un ensemble p dale Comme les deux mains sont libres pour le montage du manchon sur le conducteur l CTFP 40 est l appareil id al pour l...

Page 16: ...oduire la fixation pour table 4 dans le trou correspondant de l appareil mobile de table et visser fermement la table de travail V rifier l alimentation en air sous pression Air filtr pression mini 4...

Page 17: ...aisser l axe 4 Repousser la pince 5 l int rieur Viser en douceur la vis hexagonale interne 6 Figure 4 Nettoyage 4 2 Graissage D visser le capuchon de la pince 1 Retirer le ressort 2 et le guide de l c...

Page 18: ...e l article correspondant Figure 6 Pi ces de rechange N Pi ce Article N N Pi ce Article N 1 Le tuyau pneumatique 008137 8 Le fronton inclusive joint 009691 2 La Caisse 001564 9 Axe 001569 3 Pied autoc...

Page 19: ...ar max 6 bar Consommation d air 0 2 liter par sertissage 5 bar Dimensions Diam tre x Longueur 200 x 135 x 75 mm Poids environ 2 8 kg missions de pression acoustique LpA 70 dB A Plaque signal tique Pan...

Page 20: ......

Reviews: