PRECAUTIONS AND GENERAL GUIDELINES 

 

This symbol is used to call your attention to hazards or unsafe practices which could result in an 
injury or property damage.  The signal word, defined below, indicates the severity of the hazard.  
The message after the signal word provides information for preventing or avoiding the hazard. 

 

WARNING

 

Hazards which, if not avoided, COULD result in severe injury or death. 

 

CAUTION

 

Hazards or unsafe practices which, if not avoided, MAY result in injury or property 
damage. 

 

 

 

WARNING

 

Read  and  understand  all  of  the  instructions  and  safety  information  in  this  manual  before 
operating or servicing this tool.

 

 

 

WARNING

 

Electric Shock Hazard: 
 
This tool is not insulated.  When using this unit on or near energized electrical lines, use proper 
personal protective equipment. 

 

 

WARNING

 

Wear eye protection when operating or servicing this tool. 
 
Failure to wear eye protection can result in serious eye injury from flying debris or hydraulic oil.

 

 

 

WARNING

 

Skin Injection Hazard: 
 
Oil under pressure easily punctures skin causing serious injury, gangrene, or death.  If you are 
injured by escaping oil, seek medical attention immediately. 

 

Do not use hands to check for leaks. 

 

Depressurize the hydraulic system before servicing. 

 

 

WARNING

 

Keep hands away from the tool head when crimping. 

Summary of Contents for CT-980

Page 1: ...ess mainly focus on the distribution of electronic components Line cards we deal with include Microchip ALPS ROHM Xilinx Pulse ON Everlight and Freescale Main products comprise IC Modules Potentiometer IC Socket Relay Connector Our parts cover such applications as commercial industrial and automotives areas We are looking forward to setting up business relationship with you and hope to provide you...

Page 2: ...11 Website www panduit com Email techsupport panduit com EU Website www panduit com emea EU Email emeatoolservicecenter panduit com Panduit Corp Tinley Park IL USA Technical Support Tel 888 506 5400 ext 3255 Panduit Europe EMEA Service Center Almelo Netherlands Tel 31 546 580 452 Fax 31 546 580 441 ...

Page 3: ...S ARE USED USE OF ANY OTHER BRAND OF COMPRESSION CONNECTORS IS NOT RECOMMENDED Consult product packaging Panduit catalog or website for information on recommended connectors Weight 11 4 lbs 5 2 kg Dimensions 23 0 L x 7 25 H x 2 5 W in 585 L x 185 H x 65 W mm Handle Span 15 00 in 380 mm Open 5 75 in 145 mm Closed CT 980 Carrying Case Included with CT 980 Tool NOTE In the interest of higher quality ...

Page 4: ... the hazard The message after the signal word provides information for preventing or avoiding the hazard WARNING Hazards which if not avoided COULD result in severe injury or death CAUTION Hazards or unsafe practices which if not avoided MAY result in injury or property damage WARNING Read and understand all of the instructions and safety information in this manual before operating or servicing th...

Page 5: ...peration Protect the tool from rain and moisture Use this tool for the manufacturer s intended purpose only IMPORTANT INFORMATION Keep the tool head and tool body portion clean and free from debris Excessive dirt and grit can contribute to the premature wear of the tool s internal mechanical parts When not using the tool regularly check that no foreign matter or debris exists in the open areas bet...

Page 6: ...ors and special applications To open the tool top pull the D ring to disengage the lockout pin so that the tool top can swing open Before crimping lock the tool top in the closed position by lowering the tool top and sliding the lockout pin completely through the tool head and both surfaces of the tool top Failure to lock the tool top in the closed position may result in damage to the tool and per...

Page 7: ... the lockout pin see Fig 2 on Page 5 Carefully position the connector against the stationary indenter in the hinged tool top 4 With the tool supported pump the top handle to initiate rapid advance of the indenters toward the connector Stop pumping immediately when the indenters contact the connector 5 Verify that the connector matches the conductor size Insert the conductor completely into the con...

Page 8: ...d a pressure relief valve will automatically activate and the pump handle effort will suddenly decrease Stop pumping the top handle when this occurs The crimp is complete 9 To retract the indenters raise the top handle of the tool Rotate the top handle clockwise approx 1 8 turn until it stops With the handle in this position the relief stem in the handle will be aligned with the pressure release p...

Page 9: ... It is recommended that the hydraulic fluid be changed every 24 months The tool should be returned to Panduit Tool Solutions Division for proper oil changing CLEANING AND LUBRICATION OF TOOL HEAD Thorough cleaning and lubrication of the tool head is recommended annually depending on usage It is recommended that the CT 980 Tool be returned to Panduit Tool Solutions Division for proper maintenance b...