background image

Part No. CT-1550

OPERATION INSTRUCTIONS

Contour Crimp

CONTROLLED CYCLE

CRIMPING TOOL

Crimps most Panduit #22-#10 AWG

insulated terminals & splices; and

specific insulated disconnects.

Reduced crimp effort advantage

for #22-#14 AWG terminations.

Provides UL Listed and CSA Certified terminations

with applicable Panduit terminals.

INSULATED TERMINAL CRIMPING

INSTRUCTIONS

NOTE:  

Visual  inspection  dots  (formed  by  the

crimp dies) on the insulation sleeve verify

proper crimp cycle.

          •  Two  (2)  dots  for  red  and  blue  crimp

pocket

          •  Three (3) dots for yellow crimp pocket.

1.  With the handles in the 

closed

position, (See

Figure 1), rotate the locator until the narrow slot

is  centered  between  the  crimp  pockets  (See

Figure 2).  The locator will detent and “lock” in

this position.  Squeeze the handles to open the

tool.    With  the  back  of  the  terminal  tongue

turned toward the color dots, insert the terminal

in  the  proper  crimp  pocket  (See  Figure  1)  so

that the tongue slides into the locator slot (See

Figure  3).    Refer  to  product  packaging  for

selection of proper crimp pocket.

2.  Hold the terminal against the locator and close

the  handles  until  the  barrel  is  held  snugly  in

place—do not deform the barrel.

3.  Insert  the  stripped  wire  into  the  terminal  until

the  wire  stops  in  the  recessed  slot  in  the

locator.    Refer  to  product  packaging  for  wire

strip length.

4.  Crimp the terminal by closing the handles until

the  controlled  cycle  mechanism  releases.

Upon release, the handles will open automati-

cally and the crimped terminal can be removed.

INSULATED SPLICE AND FULLY

INSULATED DISCONNECT CRIMPING

INSTRUCTIONS

1.  With the handles in the 

open

position, swing the locator out of the way (See Figure 4).  The locator will detent and “lock”

in this position.  For splices, insert the splice in the proper crimp pocket (See FIgure 1) so that the crimp is located on

the barrel of the splice (See Figure 5).  For fully insulated disconnects, insert the disconnect in the proper crimp pocket

(See Figure 1) so that the crimp is located on the barrel of the disconnect (See Figure 6).  Refer to product packaging

for selection of proper crimp pocket.

2.  Close the handles until the barrel is held snugly in position—do not deform the barrel.
3.  Insert the stripped wire into the barrel until the wire stops. Refer to product packaging for wire strip length.  Crimp by

closing the handles until the controlled cycle mechanism releases.  Upon release, the handles will open automatically

and the crimped splice or disconnect can be removed.  

After crimping, inspect that the crimp is centered on the

disconnect barrel in order to achieve optimal pullout performance.

4.  For splices, remove the splice and repeat operation for crimping the other end of the splice.

Figure 4

Figure 5

Figure 6

Figure 7

© Panduit Corp. 2017

PA22151A04

Rev.: 06  1-2017

C

T

-1

5

5

0

22 - 14

12 - 10

22 - 14

12 - 10

Die Closure Alignment
  (not a crimp pocket)

Locator

M

a

d

e

 in

 G

e

rm

a

n

y

CRIMP POCKETS FOR
Pan-Term INSULATED
terminals, disconnects,
splices and wire joints.
Refer to product packaging
for wire range and proper
crimp pocket. Crimp pockets
are color coded to match
color of terminal insulator,
and identified with applicable
wire range. 

Controlled cycle mechanism
prevents tool from opening
before crimp cycle is completed.

Manual release lever, push
forward in the event that
controlled cycle mechanism
must be released.

Cushioned Handle Grips

Figure 1

Figure 2

Figure 3

Email:

[email protected]

EU Website: www.panduit.com/emea

EU Email: [email protected]

Technical Support:

Tel: 1-800-777-3300

Panduit Europe • EMEA Service Center

Tel: 31 (0) 546 580 452 • Fax: 31 (0) 546 580 441

CT-1550

OPERATION INSTRUCTIONS

Page: 1 of 2

CAUTION: Verify  power  is  “OFF”

before  working  on  wiring  with  this

tool.    The  cushioned  grips  are  for

the  user’s  comfort,  and  are  not

intended  to  insulate  against  shock

while  working  on  live  electrical

circuits.

www.panduit.com