background image

AT-UHD-CAT-4ED

32

The Web Server

RS-232 page

RS-232 Parameter Setting

 

Click each of these drop-down boxes to select the desired baud rate, data bits, parity bit, and stop bit for the 

MASTER RS-232 / IR

 port.

Setting

Description

Baud rate

Sets the baud rate.  The following options are available: 2400, 9600, 19200, 38400, 

56000, 57600, 115200.

Data bit

Sets the number of data bits used to represent each character of data.  The following 

options are available:  7 or 8.

Parity

Sets the parity bit, which can be included with each character to detect errors during 

the transmission of data.  The following options are available:  None, Odd, or Even.

Stop bit

Sets the stop bit.  Stop bits are sent at the end of each character, allowing the client to 

detect the end of a character stream.  The following options are available:  1 or 2.

Summary of Contents for ATLONA AT-HDR-CAT-4EDLA

Page 1: ...AtlonaManuals DistributionAmplifiers AT UHD CAT 4ED HDMI to HDBaseT Distribution Amplifier 4K UHD TM...

Page 2: ...ion Release Date Notes 1 Mar 2019 New format 2 Mar 2021 Included instructions for Updating the Valens Firmware page 39 3 Apr 2022 Corrected wiring instructions for IR control of source and sink device...

Page 3: ...rive San Jose CA 95134 United States Office 1 408 962 0515 Sales and Customer Service Hours Monday Friday 6 00 a m 4 30 p m PST https atlona com International Headquarters Atlona International AG To d...

Page 4: ...the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This equ...

Page 5: ...ecting EDID Presets 16 Managing Users 17 Adding Users 17 Editing Deleting Users 18 RS 232 Control 19 Determining the Port Type 19 Cable Assembly 20 Pass through mode 21 Control mode 22 IR Control 23 C...

Page 6: ...hannel audio compliant EDID management Intuitive GUI based configuration using integrated web server TCP IP RS 232 and IR control Easy to configure and manage with AMS Atlona Management System Field u...

Page 7: ...control system to this port to control the AT UHD CAT 4ED 12 RS 232 IR 1 4 Connect a control system or other DTE device to these ports for pass through zone control Each of these ports uses the associ...

Page 8: ...ports is associated to the respective HDBaseT OUT port This allows RS 232 pass through zone control of a display sink device that is connected to a PoE compatible receiver Control can be performed us...

Page 9: ...isplay Display Display Display H D M I PO WE R LIN K FW AT UH D E X 7 0C RX AT UHD EX 70C RX H D M I PO WE R LIN K FW AT UH D E X 7 0C RX AT UHD EX 70C RX H D M I PO WE R LIN K FW AT UH D E X 7 0C RX...

Page 10: ...ss and hold the POWER button for approximately 15 seconds Release the POWER button once the LOCK LED indicator begins to flash The number of flashes will indicate the currently selected IP mode Settin...

Page 11: ...by the DHCP server if present The System page page 35 in the web server allows the AT UHD CAT 4ED to use either DHCP or static IP mode In order to access the web server the IP address of the AT UHD C...

Page 12: ...e sure a secure connection exists between the HDMI port on the AT UHD CAT 4ED and the source display device Try a different HDMI cable HDBaseT 1 4 Blue Normal operation Signal integrity between the AT...

Page 13: ...for five seconds then release The LOCK LED indicator will no longer be illuminated Using the Front Panel Using the web server TX TX RX RX 4 3 2 4 3 2 1 1 RS 232 MASTER IN OUT LAN HDMI HDBaseT OUT DC 4...

Page 14: ...splay sink device Make sure that the sink device is powered Learning an EDID using the Front Panel HDBaseT OUT 1 HDMI Display AT UHD CAT 4ED AT UHD EX 100CE RX 4 3 2 1 OUT IN HDM I HDB aseT LOC K EDID...

Page 15: ...o switch between LOCK and UNLOCK states 4 Click the EDID mode drop down list and select LEARN 5 Click the COPY button to copy the downstream EDID to memory The AT UHD CAT 4ED will now use the EDID of...

Page 16: ...t The selected EDID will be used by the source before sending A V data to the display sink device NOTE If the resolution and timing limitations of all displays connected to the HDBaseT OUT ports are u...

Page 17: ...tory default username and password for the admin user are listed below Username root Password Atlona 3 Click the Config tab 4 Click the Add button under the Edit column 5 Enter the desired username an...

Page 18: ...Atlona a Click Config in the menu bar b Click the Edit button next to the user to be changed c Enter the new information for the user in the Username Password Edit dialog box d Click the Save Change...

Page 19: ...ot always the case If the port type is unknown then a multimeter can be used to determine whether the port is DTE or DCE Determining the Port Type 1 Turn on the multimeter and set it to measure DC vol...

Page 20: ...the TxD RxD and GND wires Cable Assembly When connecting a DTE device to a DCE device a straight through cable should be used A straight through cable is wired in such a way that the pins on one side...

Page 21: ...RX TX 1 Connect the RS 232 cable from the control system to the desired RS 232 IR port on the AT UHD CAT 4ED Refer to Cable Assembly page 20 for instructions on preparing the cable 2 Connect an Ethern...

Page 22: ...COM NC NO 12V SIG GND 12V SIG GND 12V SIG GND 12V SIG GND 1 COM PON ENT HDM I 1 2 3 4 5 6 SER IAL 1 IR OUT SER IAL 2 L R DIGI TAL COA X OUT AUD IO OUT AUD IO IN ETH ERN ET 2 3 4 VIDE O OUT 48V DC FAC...

Page 23: ...ect the GND terminal from the AT UHD CAT 4ED to the GND terminal on the control system 4 3 2 1 OUT IN HDMI HDBaseT LOCK EDID POWER INT LEARN TX RX 4 3 2 4 3 2 1 1 STER UT HDBaseT OUT DC 48V IR FW TX T...

Page 24: ...e but do not overtighten 5 Connect the captive screw connector to the RS 232 IR IN port of the zone to be controlled Controlling Source Devices IR Emitter RS 232 IR 1 HDBaseT HDBaseT OUT 1 IR Receiver...

Page 25: ...button will be blue Pressing the POWER button again will place the unit into standby mode and the POWER button will be red In standby mode no video signal will pass to the display sink device However...

Page 26: ...Web Server page 29 for more information The factory default username and password are listed below Username root Password Atlona 4 Click System in the menu bar 5 Click the Power button mode drop down...

Page 27: ...CEC power on and power off commands by pressing the ON and OFF buttons near the bottom of the page 7 Press the POWER button on the front panel to power on or power off the display Note that the power...

Page 28: ...he POWER button on the front panel to power on or power off both the display and AT UHD CAT 4ED Consumer Electronics Control CEC Atlona has confirmed proper CEC functionality with several current mode...

Page 29: ...refer to IP Configuration page 10 The default static IP address of the AT UHD CAT 4ED is 192 168 1 254 Introduction to the Web Server 1 Launch a web browser 2 In the address bar type the IP address o...

Page 30: ...AT UHD CAT 4ED 30 The Web Server 7 The Info page will be displayed 8 Click Logout on the far right side of the menu bar to log out of the web server and return to the Login page...

Page 31: ...of firmware that the AT UHD CAT 4ED is running Always make sure to check the AT UHD CAT 4ED product page on the Atlona web site for the latest version of firmware Output 1 VALENS Version Output 4 VAL...

Page 32: ...200 38400 56000 57600 115200 Data bit Sets the number of data bits used to represent each character of data The following options are available 7 or 8 Parity Sets the parity bit which can be included...

Page 33: ...ed source device to determine what video and audio formats can be sent to the sink device Refer to EDID Management page 14 for more information INT EDID settings Click this drop down list to select th...

Page 34: ...Password Enter the new password for the root username in this field Confirm New Password Verify the new password by retyping it in this field All User Login Settings Username Displays the username Pas...

Page 35: ...e Click this toggle to set the login mode to either ON or OFF If this feature is set to ON then the AT UHD CAT 4ED will prompt for both the username and password at the start of a Telnet session Use t...

Page 36: ...l Power on and power off commands are sent over both the HDBaseT OUT and HDMI OUT ports Reset to Default Click the Factory Default button to set the AT UHD CAT 4ED to factory default settings Firmware...

Page 37: ...cable from the computer containing the firmware to the same network where the AT UHD CAT 4ED is connected 2 Go to the System page page 35 in the web server Appendix 3 Click the Choose File button und...

Page 38: ...USB A to USB mini B cable between the PC and the firmware port on the AT UHD CAT 4ED 5 The USB UPDATE folder will be displayed If this folder is not displayed automatically select the USB UPDATE drive...

Page 39: ...nect an Ethernet cable from the computer containing the firmware to the same network where the AT UHD CAT 4ED is connected 2 Go to the System page page 35 in the web server 3 Click the Choose File but...

Page 40: ...ect the USB A to USB mini B cable between the PC and the firmware port on the AT UHD CAT 4ED 5 The USB UPDATE folder will be displayed If this folder is not displayed automatically select the USB UPDA...

Page 41: ...for recommended cabling when using Altona products with HDBaseT The green bars indicate the signal quality when using each type of cable Higher quality signals are represented by more bars EIA TIA 568...

Page 42: ...t Parity Stop bit 115200 8 None 1 EDID EDID lock EDID mode INT EDID settings UNLOCK INT STD Config Username default Password default root Atlona System IP Mode Static IP Address default Netmask Gatewa...

Page 43: ...Hz 1152 870 75 Hz 1024 768 60 Hz 848x480 60 Hz 800 600 60 Hz 640 480 60 Hz Color Space YUV RGB Chroma Subsampling 4 4 4 4 2 2 4 2 0 Color Depth 8 bit 10 bit 12 bit Audio HDMI HDBaseT Pass Through For...

Page 44: ...W 1 x Mini USB DC 48V 1 x 3 pin DIN Environmental Fahrenheit Celsius Operating Temperature 32 to 122 0 to 50 Storage Temperature 4 to 140 20 to 60 Operating Humidity RH 20 to 90 non condensing Power C...

Page 45: ...US International atlona com 408 962 0515 41 43 508 4321 35230 R5...