OPERATION MAINTENANCE MANUAL
| Issue 06 | 1st February 2019
© Pandrol 2019
4
of
6
1.2 Preheating Parameters
Propane
Oxygen
Burner Height
Time
PLA 25
0,25 – 0,30
0,50 – 0,51
50mm
4 minutes
PLA 68
0,25 – 0,30
0,50 – 0,51
70mm
7 minutes
1.3 Using the gauge
Several options can be found on the gauge for customisation or maintenance:
•
Turning the gauges On / Off:
•
To turn the gauge on and start the pressure readings, press the button “Enter”. The gauge can be turned off by
pressing the enter button for 5s.
•
Resetting the gauge to Zero.
•
At start up, and when the cylinders are closed, the gauge must display 0. If not, press the “zero” button for 1
second to reset the pressure sensor.
•
Adjusting the backlight timer
•
Go to the menu then scroll across until “LIGHT” is displayed. Then press “enter” and then the arrow to select
the duration of backlighting. Once chosen, press enter to confirm your choice.
•
Changing the battery
•
To change the battery, you must first remove the top panel of the Gas Box (6 screws) to access the gauge.
Then follow the instruction
(Figure 7).
Figure 5:
Figure 6: