background image

 

OPERATION MAINTENANCE MANUAL 

  |  Issue 06  |  1st February 2019

 

 

© Pandrol 2019 

of 

 

1.2  Preheating Parameters 

 

 

Propane 

Oxygen 

Burner Height 

Time 

PLA 25

 

0,25 – 0,30

 

0,50 – 0,51

 

50mm

 

4 minutes

 

PLA 68

 

0,25 – 0,30

 

0,50 – 0,51

 

70mm

 

7 minutes

 

1.3  Using the gauge 

Several options can be found on the gauge for customisation or maintenance:  

 

Turning the gauges On / Off: 

 

To turn the gauge on and start the pressure readings, press the button “Enter”. The gauge can be turned off by 

pressing the enter button for 5s. 

 

Resetting the gauge to Zero. 

 

At start up, and when the cylinders are closed, the gauge must display 0. If not, press the “zero” button for 1 

second to reset the pressure sensor. 

 

Adjusting the backlight timer 

 

Go to the menu then scroll across until “LIGHT” is displayed. Then press “enter” and then the arrow to select 

the duration of backlighting. Once chosen, press enter to confirm your choice. 

 

Changing the battery 

 

To change the battery, you must first remove the top panel of the Gas Box (6 screws) to access the gauge. 

Then follow the instruction 

(Figure 7).

  

Figure 5:   

Figure 6:   

 

 

 

 