60 av 82
OPERATION AND MAINTENANCE MANUAL I ENG_OMM_CD200IQ_P03 I 2023-03-16
@Pandrol 2023
(4)
(5)
(3)
(1)
6. Position the work head over the center of a clip
assembly.
7. Start de-clipping in manual mode by pressing
the button (6) Fig 81.
8. Run the de-clipping until the reference arms (4)
close. The four reference plates (5) should now
fit the profile of the lower parts of the head of the
rail. Adjust if necessary.
Fig 86.
Fig 84.
Fig 85.
8.3.2. Adjusting the reference plates
1. Open the arms by pressing button (5), Fig 81.
2. Adjust the four reference plates by opening the
excentric lock handle. (1), Fig 85.
3.
Position the reference plate to fit the actual rail type.
4. Position the work head in between two sleepers to
operate the arms against the mechanical stop.(3) Fig
86.
5. Check the de-clipping plate position against the rail
foot. Adjust if necessary
6. Position the work head over the center of a clip
assembly.
7. In manual operating mode, run the de-clipping
sequence by pressing the button (6) Fig 81.
8. Ensure that the clips are completely retracted.
9. If the clips are not fully retracted, adjust the
mechanical stop screw (3) Fig 86.