background image

P&N Technology                                                                                                                                  PN-D3024D

 

Page 

3

 of Page 4

 

6.

 

Drainage system condenses condensate water out of the cabinet timely. 

7.

 

Start and stop dehumidification values are adjustable; 

8.

 

Automatic defrosting at low temperature; 

9.

 

Automatic  stopping  at  high  temperature  and  double  temperature  switch 

protection. 

 

Technical Parameters 

Project 

Technical parameters 

Working power supply

 

DC 24V

 

Electric power

 

30W 

Humidity detection range

 

1%RH

99%RH 

Humidity measurement accuracy

 

±

3%RH 

Dehumidification start value

 

55%RH

Adjustable

 

Dehumidification stop value

 

35%RH

Adjustable

 

Dehumidifying capacity

 

250ml/24h

35

  RH=85%

 

Storage temperature

 

-30

℃~

70

 

Operating temperature

 

-10

℃~

55

 

Outline dimension

 

104mm*64mm*66mm 

Net weight

 

320g 

Aqueduct specification

 

Heat-resistant silicone pipe    L=1m 

 

User Guide 

1.

 

Install the dehumidification device

 

vertically

 in the cabinet; 

2.

 

Turn on electricity          Automatic real-time detection of humidity in the cabinet                         

Reviews: