● TUNE BASE (“tBS”)
Value: 428-452 (Hz). (Default on reset is 440.)
This sets the tuning of the synthesizer when it is triggered using the MIDI IN.
(Triggering the synthesizer using the audio input is
no
t affected by this parameter as
the tuning of the synthesizer is
always
locked to the pitch of the audio input signal.)
This also sets the base of the
Important:
If you update your FI’s firmware to v3.60 from a pre-v3 version then the
Tune Base will not be at 440 Hz and so the Tuner will show “incorrect” pitch values.
You must reset the Tune Base. You can do this by performing a RESET ALL.
Alternatively,
if you do not want to lose any program settings
made with the
PARAMETER and EDIT dials, you can manually set the Tune Base to 440 Hz (or any
other desired value).
● INSTRUMENT MODE (“InS”)
Value: bSS (Bass), SPL (Split), Gtr (Guitar), Snt (Synth), EUI (EWI). (Default on reset
is bSS.)
Choose the option for your instrument. If your instrument is not listed above then
choose either Bass or Guitar, whichever one best fits the pitch range of your
instrument.
See the
section for full details of the different modes.
●
MIDI THRU (“trU”)
Value: 0, 1 (Default on reset is 0.)
If set to 0 then MIDI information received via MIDI IN will
not
be passed to MIDI OUT.
If set to 1 then all information received via MIDI IN
will
be passed to MIDI OUT (with
the exception of CC6 (Data Edit), NRPN controllers and SysEx data).
Updating the Firmware of the Future Impact v3
You should always make sure the latest firmware version is installed on your FI (now
v3.60
).
Check the firmware version number shown in your pedal’s display when powering on. If a
number lower than 3.60 is shown then you will need to update the firmware.
You can update
any
FI unit’s firmware to the latest version directly in your web browser
(Chrome only) by going to
https://auraplug.com/fiupdate/start.html
and following the
on-screen instructions.
18