background image

19

ENGLISH

Setting the microphone sensitivity

Sets the sensitivity to audio collected by the microphone unit.

1

Power indicator

2

4

Battery cover

A

1
2

ON

3

Make sure that the [PWR] indicator is off

Remove the battery cover

Press on the portion labeled as   on the back of the battery cover and slide the cover 

downwards to remove it.

Set the microphone sensitivity

Set the sensitivity setting switch. Use the tip of a pen, screwdriver, or other narrow 

pointed object to control the switch. The settings for the switch are as follows.
[SENS L]: Low sensitivity (factory default) 

[SENS H]: High sensitivity 

Place the battery cover back on

Slide the battery cover upwards to place it back on.

memo

Important

 

Changing this setting while the microphone is turned ON could lead to 

noise. Turn down the volume on the power amplifier or mixer before 

changing this setting.

memo

Important

 

Set the sensitivity to “Low” when the microphone unit is close to the mouth.

 

Set the sensitivity to “High” when the microphone unit is far from the mouth 

or when the volume of voice is low.

PGQX2327VAV6_WX-ST400_OI_en-fr.indb   19

2022/01/24   11:23:24

Summary of Contents for WX-ST400

Page 1: ...nstructions carefully and save this manual for future use The model number is abbreviated in some descriptions in this manual Operating Instructions Wireless Microphone Model No WX ST400P ENGLISH FRANÇAIS PGQX2327VA PGQX2327VAV6_WX ST400_OI_en fr indb 1 2022 01 24 11 23 21 ...

Page 2: ...peration This transmitter must not be co located or operated in conjunction with any other antenna or transmitter MEDICAL Consult the manufacturer of any personal medical devices such as pacemakers to determine if they are adequately shielded from external RF radio frequency energy The unit operates in the frequency range of 1 92 GHz to 1 93 GHz and the power output level is 115mW max Supplier s D...

Page 3: ...our purchase to aid identification in the event of theft Model No ________________________ Serial No ________________________ For U S A CAUTION The FCC ID number for this radio equipment is listed below FCC ID ACJ9TAWX ST400P For U S A CAN ICES 3 A NMB 3 A For Canada RSS Gen Under Industry Canada regulations this radio transmitter may only operate using an antenna of a type and maximum or lesser g...

Page 4: ...cturer 9 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over 10 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid h...

Page 5: ...ITY FITNESS FOR ANY PARTICULAR PURPOSE OR NON INFRINGEMENT OF THE THIRD PARTY S RIGHT THIS PUBLICATION COULD INCLUDE TECHNICAL INACCURACIES OR TYPOGRAPHICAL ERRORS CHANGES ARE ADDED TO THE INFORMATION HEREIN AT ANY TIME FOR THE IMPROVEMENTS OF THIS PUBLICATION AND OR THE CORRESPONDING PRODUCT S Disclaimer of Warranty IN NO EVENT SHALL Panasonic Connect Co Ltd BE LIABLE TO ANY PARTY OR ANY PERSON E...

Page 6: ...ed In addition exporting any software provided with this product violating export laws is prohibited Abbreviations This manual uses the following abbreviations Wireless Microphone WX ST400P is referred to as this product the product or microphone Charger WX SZ200P sold separately is referred to as charger Wireless Antenna WX SA250P sold separately is referred to as wireless antenna or antenna Wire...

Page 7: ...8 Setting the microphone sensitivity 19 Pairing 20 Pairing with the WX SR202P WX SR204P WX SE200P wireless connection 20 Pairing with the WX SR202P WX SR204P WX SE200P wired connection 22 Confirming pairing 25 Attaching the microphone 27 Using the microphone 28 Connecting an external device 29 Replacing the battery 30 Recharging the battery 32 Troubleshooting 35 Specifications 38 Standard accessor...

Page 8: ...mitted from the product may interfere with the medical equipment causing it to malfunction and lead to accidents Do not use near automatic doors fire alarms and other automatic controllers The radio waves emitted from the product may interfere with the automatic controllers causing them to malfunction and lead to accidents Do not place on unstable surfaces The product may fall leading to accidents...

Page 9: ... positive negative Failing to do so may cause the batteries to leak or burst leading to fires injuries and damage to the surroundings Do not install at places exposed to large amount of humidity and or dust It may lead to injury Do not install the product where children may reach it It may lead to injury Do not use Ni Cd batteries Internal damage may lead to fires PGQX2327VAV6_WX ST400_OI_en fr in...

Page 10: ... outside of this range may cause it to malfunction or to be damaged When calculating the usage time consider that the batteries will last less than usual below 10 C 50 F Storage and usage locations Avoid using the product where it could be affected by motors transformers or the ignition noise of cars Be especially careful when using the product in a high place It may fall leading to malfunctions a...

Page 11: ...efully read the included instructions If the battery poles or the components behind the battery cover are dirty clean them thoroughly with a dry soft cloth The components behind the battery cover get dirty very easily Clean them periodically around once per month with ethyl alcohol Do not use solvents such as benzene or paint thinner or abrasive metal polishes as they will damage the shape and col...

Page 12: ...12 Parts and their names 1 2 O N 1 2 O N Front Side Rear Battery cover removed Rear Top C D A B F G H I J K L M E PGQX2327VAV6_WX ST400_OI_en fr indb 12 2022 01 24 11 23 23 ...

Page 13: ... may be absent Make sure that the proper type of battery is inserted The battery may be outside of the operating temperature range Make sure that the battery is within the operating temperature range CPower indicator PWR Shows the battery status On green Power ON On orange Power ON less than one hour of battery runtime remaining On red Battery almost depleted recharge or exchange the battery Off P...

Page 14: ...itch Turns the microphone ON OFF Pressing the power switch will turn the microphone ON and audio from the microphone unit will be transmitted Pressing the power switch again while the microphone is ON will turn the microphone OFF EMicrophone unit Collects audio A windscreen is attached to the microphone unit The windscreen is an expendable component which deteriorates with use Refer to a retailer ...

Page 15: ...ng confirmation Press the REG button once while the power switch is set to ON to enter pairing confirmation mode page 25 The pairing confirmation mode lasts for five seconds on both the microphone and the receiver after which both will go back to their normal operation mode MConnector for configuration and maintenance SET inside the battery cover Micro USB 2 0 type B connector to connect the produ...

Page 16: ...r A 3 Battery slot Battery locally procured 1 Make sure that the PWR indicator is off 2 Remove the battery cover Press on the portion labeled as on the back of the battery cover and slide the cover downwards to remove it 3 Insert the battery Check the polarity of the battery positive and negative and insert either one rechargeable Ni MH AA type battery or one AA type alkaline dry cell battery in t...

Page 17: ... will be around eight hours Some batteries may not perform well with this product If possible use one of the recommended batteries The recommended batteries are as follows Rechargeable battery BK 3MCCA Panasonic Ni MH AA size battery Dry cell batteries LR6PA Panasonic alkaline AA size battery LR6XE Panasonic alkaline AA size battery PGQX2327VAV6_WX ST400_OI_en fr indb 17 2022 01 24 11 23 24 ...

Page 18: ...hone unit Microphone clip The microphone holder can be attached such as to fit different types of clothing Pinch the microphone clip from both sides as shown in the illustration below to remove it from the microphone holder Rotate the microphone holder as necessary and re attach it to the microphone clip PGQX2327VAV6_WX ST400_OI_en fr indb 18 2022 01 24 11 23 24 ...

Page 19: ...nted object to control the switch The settings for the switch are as follows SENS L Low sensitivity factory default SENS H High sensitivity 4 Place the battery cover back on Slide the battery cover upwards to place it back on memo Important Changing this setting while the microphone is turned ON could lead to noise Turn down the volume on the power amplifier or mixer before changing this setting m...

Page 20: ...ximum number of simultaneously usable microphones WX SR202P 6 per channel 2 1 per channel WX SR204P 6 per channel 4 1 per channel WX SE200P 6 per channel 4 1 per channel Also refer to the wireless receiver extension receiver manual Pairing with the WX SR202P WX SR204P WX SE200P wireless connection Pair the microphone to a wireless antenna via a wireless connection Perform the pairing within the co...

Page 21: ...red and the REG indicator on the paired channel on the wireless receiver extension receiver lights green for one second and then goes off If pairing could not be completed successfully the PWR indicator on the microphone will blink red In that event place the microphone as close as possible to the antenna and try pairing it again Pairing may fail if the microphone is too far away from the antenna ...

Page 22: ...as on the back of the battery cover and slide the cover downwards to remove it 2 Connect the microphone to the wireless receiver extension receiver Connect the SET connector of the microphone to the SET connector of the wireless receiver via a USB 2 0 cable micro type B male to type A male locally procured and a conversion cable type A female to Micro type B male locally procured Also when you wis...

Page 23: ... Type A Female Type A Male USB 2 0 cable locally procured Micro type B Male Connector for SET Connector for SET This illustration shows the WX SR202P 3 Turn the microphone ON If the microphone is currently OFF turn the power switch to ON When the microphone and the wireless receiver extension receiver are connected via a cable the audio from the microphone will not be transmitted Power indicator P...

Page 24: ... one second and goes off If pairing could not be completed successfully the PWR indicator on the microphone will blink red This illustration shows the WX SR202P Register button Power indicator Register indicator 5 Unplug the microphone from the wireless receiver extension receiver Unplug the cables connecting the microphone to the wireless receiver extension receiver If pairing has been completed ...

Page 25: ...hat the POWER indicator on the wireless receiver extension receiver lights green Power indicator This illustration shows the WX SR202P 3 Set the microphone to pairing confirmation mode With the microphone powered on press the REG button once to enter pairing confirmation mode the PWR indicator will turn green and orange alternately for five seconds A Power indicator Register button PGQX2327VAV6_WX...

Page 26: ...tton once during pairing confirmation mode to go back to the normal operation mode Register indicator This illustration shows the WX SR202P memo Important If the PWR indicator on the microphone blinks red the microphone is not paired to a wireless receiver extension receiver Perform the steps described in Pairing page 20 The pairing confirmation can also be performed from the wireless receiver ext...

Page 27: ...microphone to the belt Hook 2 Attach the microphone with the microphone clip Use the included microphone clip to attach the microphone unit to a necktie or collar Attach it as close as possible to the mouth to ensure the best audio clarity Microphone clip Attaching the microphone PGQX2327VAV6_WX ST400_OI_en fr indb 27 2022 01 24 11 23 26 ...

Page 28: ...tch once more to turn the microphone OFF The PWR indicator goes off memo Important Do not place the microphone near the speakers Doing so may cause howling and other loud noises which may cause injuries to the ears memo Important If the microphone moves out of the antenna range the PWR indicator blinks orange and the microphone stops audio transmission Move the microphone back into the antenna ran...

Page 29: ...e audio output from the external device eg portable CD player to the AUDIO IN connector 3 Turn ON the external device eg portable CD player 4 Turn ON the microphone memo Important When a Ø3 5 mm stereo mini plug is connected to the AUDIO IN connector this audio source is given priority and the audio from the microphone unit stops transmission If the external device outputs stereo audio the L R cha...

Page 30: ...o may cause connection problems or noise If the battery poles become dirty clean them with a dry soft cloth Even when the power is turned OFF battery left inside the product will slowly be drained Remove the battery when you are not using the microphone for an extended period of time as failing to do so may cause battery leaks Power indicator 2 4 Battery cover A 3 1 5 Power switch Battery locally ...

Page 31: ... microphone ON and check that the PWR indicator lights either green or orange memo Important When recharging Ni MH batteries only use the original charger WX SZ200P The charging time depends on the battery type and the specific use situation but at longest it will be around eight hours Some batteries may not perform well with this product If possible use one of the recommended batteries The recomm...

Page 32: ...ng complete or the microphone is not set correctly on the charger Blinking Usually caused by one of the following The microphone may contain a dry cell or deteriorated rechargeable battery or the battery may be absent Make sure that the proper type of battery is inserted The rechargeable battery may be outside of its operating temperature range Make sure that the battery is within its operating te...

Page 33: ...ition Hold the charger with your hand when removing a microphone from it memo Important If once charging is complete the battery in the microphone spontaneously drains charging will not start again even if the microphone is still inserted into the charger If the CHG indicator does not light up despite the microphone being inserted into the charger confirm that all the links between charger AC adap...

Page 34: ...ay take some time and the CHG indicator stay lit until the recognition completes Sometimes when trying to recharge almost full batteries at very low temperatures these may be mistakenly recognized as dry cell batteries and the CHG indicator may start blinking The microphone is charged through inductive charging Because of inductive charging regulations the PWR indicator on the microphone may go of...

Page 35: ... then turn it ON 32 Is the battery depleted If it is replace it if it is the dry cell battery or charge it if it is the rechargeable battery 30 32 Is the battery inserted according to the correct polarities Positive negative Make sure that the battery is inserted correctly 16 30 The PWR indicator blinks red and I cannot use the microphone The microphone is not paired Alternatively there could have...

Page 36: ...is turned OFF it will take precedence over the microphone unit which will stop audio transmission from the microphone unit Disconnect the plug from the AUDIO IN connector 29 Is the volume on the receiver connected amplifier etc high enough Adjust the volume with the volume adjustment knob I cannot charge the microphone The CHG indicator stays off Is the microphone properly inserted into the charge...

Page 37: ...ized 34 Is the battery extremely hot Check the battery temperature 32 Have you inserted the rechargeable battery Make sure that you have inserted the rechargeable battery 16 Is the battery inserted according to the correct polarities Positive negative Make sure that the battery is inserted correctly 16 30 The battery runtime is short despite being fully charged Is the battery you are using deterio...

Page 38: ...tteries Approx 8 hours Ni MH AA size battery BK 3MCCA Approx 6 hours Alkaline AA size battery LR6PA Approx 8 hours Alkaline AA size battery LR6XE Display indicators Power Charge Operating temperature range 5 C to 35 C 41 F to 95 F Operating humidity range 10 to 90 no condensation Dimensions Transmitter 60 mm W x 97 mm H x 20 mm D 2 3 8 inches x 3 13 16 inches x 13 16 inches Microphone unit Maximum...

Page 39: ...ies Operating Instructions this booklet 1 Warranty Card 1 Microphone clip 1 Microphone holder pre attached 1 Windscreen pre attached 1 Microphone identification sticker 1 PGQX2327VAV6_WX ST400_OI_en fr indb 39 2022 01 24 11 23 28 ...

Page 40: ...ccepter toute interférence reçue y compris les interférences qui peuvent causer un fonctionnement non désiré Cet émetteur ne doit pas être installé ou utilisé conjointement avec une autre antenne ou un autre émetteur MÉDICAL Consultez le fabricant des dispositifs médicaux personnels tels que les stimulateurs cardiaques pour déterminer s ils sont correctement protégés de l énergie dégagée par les f...

Page 41: ...érences nuisibles aux communications radio L utilisation de cet équipement dans une zone résidentielle est susceptible de causer des interférences nuisibles auquel cas l utilisateur devra corriger les interférences à ses propres frais Pour les États Unis Le numéro de modèle et le numéro de série de ce produit se trouvent sur la surface de l appareil Vous devez noter le numéro de modèle et le numér...

Page 42: ...i le brouillage est susceptible d en compromettre le fonctionnement Pour le Canada IMPORTANTES CONSIGNES DE SÉCURITÉ 1 Lire ces instructions 2 Conserver ces instructions 3 Respecter ces instructions 4 Suivre toutes les instructions 5 Ne pas utiliser cet appareil près de l eau 6 Nettoyer avec un chiffon sec seulement 7 Éloigner l appareil de toute source de chaleur telle que radiateurs et autres él...

Page 43: ...OLATION DES DROITS DU TIERS CETTE PUBLICATION PEUT CONTENIR DES INEXACTITUDES TECHNIQUES OU DES ERREURS TYPOGRAPHIQUES DES MODIFICATIONS SONT AJOUTÉES AUX INFORMATIONS CONTENUES DANS LE PRÉSENT DOCUMENT À TOUT MOMENT EN VUE D AMÉLIORER LA PRÉSENTE PUBLICATION ET OU LE S PRODUIT S CORRESPONDANT S Déni de la garantie EN AUCUN CAS Panasonic Connect Co Ltd NE SERA TENU POUR RESPONSABLE POUR TOUTE PART...

Page 44: ...ressément interdits En outre l exportation de tout logiciel fourni avec ce produit en violation des lois d exportation est interdite Abréviations Ce manuel utilise les abréviations suivantes Ce produit le produit ou microphone désigne le microphone sans fil WX ST400P Le chargeur désigne le chargeur WX SZ200P vendu séparément L antenne sans fil ou l antenne désigne l antenne sans fil WX SA250P vend...

Page 45: ...e 56 Réglage de la sensibilité du microphone 57 Appairage 58 Appairage avec le WX SR202P WX SR204P WX SE200P connexion sans fil 58 Appairage avec le WX SR202P WX SR204P WX SE200P connexion filaire 60 Confirmation de l appairage 63 Fixation du microphone 65 Utilisation du microphone 66 Connexion d un dispositif externe 67 Remplacement de la pile 68 Rechargement de la pile 70 Diagnostic des pannes 7...

Page 46: ...ifs les unités de soins d urgence etc Les ondes radio émises par le produit peuvent interférer avec l équipement médical et provoquer des dysfonctionnements et des accidents Ne pas utiliser à proximité de portes automatiques d alarmes d incendie ou d autres contrôleurs automatiques Les ondes radio émises par le produit peuvent interférer avec les contrôleurs automatiques et provoquer des dysfoncti...

Page 47: ...te positif négatif Le non respect de cette consigne pourrait entraîner des fuites ou l éclatement des piles ce qui pourrait provoquer des incendies des blessures et des dommages aux alentours Ne pas installer dans des endroits exposés à une grande quantité d humidité et ou de poussière Cela pourrait entraîner des blessures Ne pas installer le produit à un endroit où les enfants pourraient l attein...

Page 48: ...calcul de la durée d utilisation tenez compte du fait que les piles dureront moins longtemps que d habitude en dessous de 10 C 50 F Emplacements de stockage et d utilisation Évitez d utiliser le produit dans un endroit où il pourrait être affecté par les moteurs les transformateurs ou le bruit d allumage des voitures Soyez très prudent lorsque le produit est utilisé dans un endroit élevé Il pourra...

Page 49: ...tructions fournies Si les pôles de la pile ou les composants derrière le couvercle du compartiment des piles sont sales nettoyez les avec précaution avec un chiffon doux et sec Les composants derrière le couvercle du compartiment des piles se salissent très facilement Nettoyez les périodiquement environ une fois par mois avec de l alcool éthylique N utilisez pas de solvants tels que le benzène ou ...

Page 50: ...50 Nomenclature des pièces 1 2 O N 1 2 O N Avant Côté Arrière Couvercle du compartiment des piles retiré Arrière Haut C D A B F G H I J K L M E PGQX2327VAV6_WX ST400_OI_en fr indb 50 2022 01 24 11 23 30 ...

Page 51: ...pproprié est inséré La pile peut se trouver en dehors de la plage de température de fonctionnement Assurez vous que la pile se trouve dans la plage de température de fonctionnement CVoyant d alimentation PWR Indique l état de la pile Allumé vert Sous tension Allumé orange Sous tension moins d une heure d autonomie restante de la pile Allumé rouge Pile presque épuisée recharger ou remplacer la pile...

Page 52: ... en marche lorsque vous appuyez sur l interrupteur d alimentation et l audio de l unité du microphone est transmis Si vous appuyez à nouveau sur l interrupteur d alimentation alors que le microphone fonctionne il s arrête EUnité de microphone Recueille l audio Une bonnette anti vent est fixée à l unité du microphone Cette bonnette anti vent est un accessoire consommable se détériorant à l usage Co...

Page 53: ...nfirmation de l appairage Appuyez une fois sur le bouton REG lorsque l interrupteur d alimentation est réglé sur ON pour accéder en mode de confirmation de couplage page 63 Le mode de confirmation d appairage dure cinq secondes sur le microphone et le récepteur après quoi tous deux retournent à leur mode de fonctionnement normal MConnecteur pour la configuration et la maintenance SET à l intérieur...

Page 54: ...ment de pile Pile à se procurer localement 1 S assurer que le voyant PWR est éteint 2 Retirer le couvercle du compartiment des piles Appuyez sur la partie indiquée par à l arrière du couvercle du compartiment des piles et faites glisser le couvercle vers le bas pour le retirer 3 Insérer la pile Vérifiez la polarité de la pile positive et négative et insérez une pile rechargeable Ni MH de type AA o...

Page 55: ...sera au maximum d environ huit heures Certaines piles peuvent ne pas fonctionner correctement avec ce produit Si possible utilisez l une des piles recommandées Les piles recommandées sont les suivantes Pile rechargeable Pile Ni MH type AA Panasonic BK 3MCCA Piles sèches Pile alcaline type AA Panasonic LR6PA Pile alcaline type AA Panasonic LR6XE PGQX2327VAV6_WX ST400_OI_en fr indb 55 2022 01 24 11 ...

Page 56: ...ce du microphone Vous pouvez fixer le support de microphone de différentes manières afin de l adapter à divers vêtements Pincez la pince du microphone de chaque côté comme indiqué sur l illustration ci dessous pour la retirer du support du microphone Tournez le support du microphone selon vos besoins puis fixez le à nouveau à la pince PGQX2327VAV6_WX ST400_OI_en fr indb 56 2022 01 24 11 23 30 ...

Page 57: ...u étroit pour contrôler l interrupteur Les réglages de l interrupteur sont les suivants SENS L faible sensibilité réglage par défaut SENS H haute sensibilité 4 Remettre le couvercle du compartiment des piles Pour remettre le couvercle du compartiment des piles faites le glisser vers le haut note Important Si vous modifiez ce réglage alors que le microphone fonctionne cela pourrait causer du bruit ...

Page 58: ... microphones pouvant être utilisés simultanément WX SR202P 6 par canal 2 1 par canal WX SR204P 6 par canal 4 1 par canal WX SE200P 6 par canal 4 1 par canal Reportez vous également au manuel du récepteur sans fil récepteur d extension Appairage avec le WX SR202P WX SR204P WX SE200P connexion sans fil Jumelez le microphone à une antenne sans fil via une connexion sans fil Effectuez l appairage dans...

Page 59: ... canal jumelé du récepteur sans fil récepteur d extension s allume en vert pendant une seconde puis s éteint Si l appairage n a pas réussi le voyant PWR du microphone clignotera en rouge Dans ce cas placez le microphone le plus près possible de l antenne et réessayez de le jumeler L appairage peut échouer si le microphone est trop éloigné de l antenne ou l état de la connexion est mauvais 4 Remett...

Page 60: ...ar à l arrière du couvercle du compartiment des piles et faites glisser le couvercle vers le bas pour le retirer 2 Connecter le microphone au récepteur sans fil récepteur d extension Connectez le connecteur du microphone SET au connecteur SET du récepteur sans fil via un câble USB 2 0 mâle micro type B à mâle type A à se procurer localement et un câble de conversion femelle type A à mâle micro typ...

Page 61: ...emelle Type A Mâle Câble USB 2 0 à se procurer localement Micro type B Mâle Connecteur pour SET Connecteur pour SET Cette illustration présente le WX SR202P 3 Allumer le microphone Si le microphone est actuellement éteint mettez l interrupteur d alimentation sur ON Quand le microphone et le récepteur sans fil récepteur d extension sont connectés via un câble l audio du microphone ne sera pas trans...

Page 62: ... voyant PWR du microphone clignotera en rouge Bouton d enregistrement Voyant d alimentation Voyant d enregistrement Cette illustration présente le WX SR202P 5 Débrancher le microphone du récepteur sans fil récepteur d extension Débranchez le câble connectant le microphone au récepteur sans fil récepteur d extension Si l appairage a terminé avec succès l audio du microphone est transmis 6 Remettre ...

Page 63: ... vous que le voyant POWER du récepteur sans fil récepteur d extension s allume en vert Voyant d alimentation Cette illustration présente le WX SR202P 3 Régler le microphone sur le mode de confirmation de l appairage Appuyez une fois sur le bouton REG d un microphone sous tension pour passer en mode de confirmation de l appairage le voyant PWR passe du vert à l orange alternativement pendant cinq s...

Page 64: ...ion de l appairage pour revenir au mode de fonctionnement normal Voyant d enregistrement Cette illustration présente le WX SR202P note Important Si le voyant PWR du microphone clignote en rouge le microphone n est pas jumelé à un récepteur sans fil récepteur d extension Effectuez les étapes décrites à la section Appairage page 58 La confirmation de l appairage peut également être effectuée à parti...

Page 65: ... la ceinture Crochet 2 Fixer le microphone avec la pince du microphone Utilisez la pince de microphone fournie pour fixer l unité du microphone à une cravate ou à un col Fixez le plus près possible de la bouche pour obtenir la meilleure clarté audio Pince du microphone Fixation du microphone PGQX2327VAV6_WX ST400_OI_en fr indb 65 2022 01 24 11 23 33 ...

Page 66: ...rophone Le voyant PWR s éteint note Important Ne placez pas le microphone près des haut parleurs Cela pourrait provoquer des hurlements et d autres bruits forts qui pourraient causer des blessures aux oreilles note Important Si le microphone se déplace hors de la portée de l antenne le voyant PWR clignote en orange et le microphone arrête la transmission audio Repositionnez le microphone dans la p...

Page 67: ...3 5 mm pour connecter la sortie audio du dispositif externe ex lecteur CD portable au connecteur AUDIO IN 3 Allumer le dispositif externe ex lecteur CD portable 4 Allumer le microphone note Important Quand une mini prise stéréo Ø3 5 mm est connectée au connecteur AUDIO IN cette source audio est prioritaire et l audio de l unité de microphone cesse la transmission Si le dispositif externe émet de l...

Page 68: ...ez les avec un chiffon doux et sec Même lorsque l appareil est hors tension la pile restant à l intérieur du produit s épuise lentement Retirez la pile quand vous n allez pas utiliser le microphone pendant une période prolongée car le non respect de cette consigne pourrait provoquer des fuites de piles Voyant d alimentation 2 4 Couvercle du compartiment des piles A 3 1 5 Interrupteur d alimentatio...

Page 69: ... mettre le microphone en marche et vérifiez que le voyant PWR s allume en vert ou en orange note Important Pour recharger les piles Ni MH utilisez uniquement le chargeur d origine WX SZ200P Le temps de charge dépend du type de pile et de la situation d utilisation spécifique mais il sera au maximum d environ huit heures Certaines piles peuvent ne pas fonctionner correctement avec ce produit Si pos...

Page 70: ... correctement réglé sur le chargeur Clignotant Généralement provoqué par l une des causes suivantes Le microphone peut contenir une pile sèche ou une pile rechargeable détériorée ou la pile peut être absente Assurez vous que le type de pile approprié est inséré La pile rechargeable peut se trouver en dehors de sa plage de température de fonctionnement Assurez vous que la pile se trouve dans sa pla...

Page 71: ...pteur d alimentation est en position ON Tenez le chargeur avec la main lors du retrait d un microphone note Important Si une fois le chargement terminé la pile du microphone se vide spontanément le chargement ne recommencera pas même si le microphone est toujours inséré dans le chargeur Si le voyant CHG ne s allume pas malgré l insertion du microphone dans le chargeur vérifiez que toutes les liais...

Page 72: ...le voyant CHG reste allumé jusqu à ce que la reconnaissance soit terminée Parfois lors de la recharge de piles presque pleines à très basse température il se peut qu elles soient reconnues par erreur comme des piles sèches et que le voyant CHG commence à clignoter Le microphone est chargé par charge inductive En raison des règles de charge inductive le voyant PWR du microphone pourrait s éteindre ...

Page 73: ...lume pas le microphone ne peut pas être allumé tant qu il est inséré dans le chargeur Extrayez le microphone du chargeur et allumez le 70 La pile est elle épuisée Si c est le cas remplacez la s il s agit de la pile sèche ou rechargez la s il s agit de la pile rechargeable 68 70 La pile est elle insérée selon les polarités correctes Positive négative Assurez vous que la pile est insérée correctemen...

Page 74: ... trouver presque en dehors de la portée de l antenne Repositionnez le microphone à l intérieur de la portée de l antenne 51 L audio de l unité de microphone n est pas transmis Un dispositif externe est il connecté au connecteur AUDIO IN Quand un dispositif externe est connecté même s il est éteint il aura priorité sur l unité de microphone qui arrêtera la transmission audio de l unité de microphon...

Page 75: ...crophone du chargeur et réinsérez le plusieurs fois jusqu à ce que les piles soient correctement reconnues 72 La pile est elle extrêmement chaude Vérifiez la température de la pile 70 Avez vous inséré la pile rechargeable Assurez vous d avoir inséré la pile rechargeable 54 La pile est elle insérée selon les polarités correctes Positive négative Assurez vous que la pile est insérée correctement 54 ...

Page 76: ...C 77 F avec des piles Panasonic Environ 8 heures Pile Ni MH type AA BK 3MCCA Environ 6 heures Pile alcaline type AA LR6PA Environ 8 heures Pile alcaline type AA LR6XE Affichage voyants Alimentation charge Plage de température de fonctionnement 5 C à 35 C 41 F à 95 F Plage d humidité de fonctionnement 10 à 90 sans condensation Dimensions Émetteur 60 mm L x 97 mm H x 20 mm P 2 3 8 po x 3 13 16 po x ...

Page 77: ... d utilisation ce livret 1 Carte de garantie 1 Pince du microphone 1 Support du microphone déjà installé 1 Bonnette anti vent déjà installée 1 Autocollant d identification du microphone 1 PGQX2327VAV6_WX ST400_OI_en fr indb 77 2022 01 24 11 23 35 ...

Page 78: ...78 MEMO PGQX2327VAV6_WX ST400_OI_en fr indb 78 2022 01 24 11 23 35 ...

Page 79: ...79 PGQX2327VAV6_WX ST400_OI_en fr indb 79 2022 01 24 11 23 35 ...

Page 80: ...5490 https na panasonic com us Panasonic Canada Inc 5770 Ambler Drive Mississauga Ontario L4W 2T3 Canada 1 877 495 0580 https www panasonic com ca Panasonic Connect Co Ltd 2022 Pav0619 4042 PGQX2327VA Printed in Vietnam PGQX2327VAV6_WX ST400_OI_en fr indb 80 2022 01 24 11 23 35 ...

Reviews: