7

!7

Auxiliary Button (AUX 1,2)

These buttons toggle the auxiliary switches in the
Receiver on and off.
The auxiliary switches can be used, for example, to
activate equipment connected to the receiver, such as
lamps and buzzers.

!8

Alternate Button (ALT)

This button activates the alternate function of dual-func-
tion control buttons.

!9

Forward Sequence Button (FORWARD SEQ)

This button is used to run a selected Program or Tour
Sequence in forward direction on the active monitor.
It also restarts a sequence forward from the step that
was previously paused by pressing the Stop button.

@0

Backward Sequence Button (BACK SEQ)

This button is used to restart a sequence backward
from the step that was previously paused by pressing
the Stop button.

@1

Alarm Acknowledge and Reset Button (ACK RESET)

This button cancels an activated alarm. To cancel an
alarm, first select the alarmed monitor(s), then press the
ACK RESET button once for alarm acknowledgment
(the indicator on the button blinks rapidly), and finally
press it again for alarm reset (the indicator goes off).
After  an alarm acknowledgment, pressing this button
while the Alternate (ALT) indicator is on will cancel all
currently activated alarms at the same time.

#1

Data Ports (DATA IN, OUT)

Exchanges control data with the WJ-SX550B Matrix
Switcher in a system.

#2

Termination Switch (TERM ON/OFF)

This switch enables termination of the controller’s data
port.

#3

Controller Unit Number Switch (CONTROLLER UNIT
NO.)

This switch is used to identify the unit number of the
System Controller in multiple system controller applica-
tions. Up to eight controllers can be installed in a sys-
tem.

#4

Mode Selection Switch (MODE)

These switches are used to set the mode of the System
Controller connected to the Matrix Switcher. Set the
switches as shown below.

Normal Mode

CAM-P Mode

MODE

ON 1

2

3

4

MODE

ON 1

2

3

4

#5

Controller On/Off Switch (CONTROLLER ON/OFF)

This switch is used to turn the WV-CU550B system con-
troller power on and off.

#6

Power Cord

Refer to the Operating Instructions of the WJ-SX550B Matrix
Switcher for further details.

NOTE

Summary of Contents for WVCU550B - SYSTEM CONTROLLER

Page 1: ...manual for future use Model No WV CU550B System Controller Operating Instructions ALARM ACK RESET AUX DEC 1CAM INC 1CAM STOP SLOW ESC SET MON CAM WIDE FAR ZOOM TELE FOCUS NEAR RESET IRIS 1 2 3 4 5 6 7 8 0 9 CLOSE OPEN 1 2 BACK SEQ FOWARD SEQ ALT BUSY LEFT System Controller WV CU550B RIGHT UP DOWN F1 F2 F3 F4 ...

Page 2: ...s equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense FCC Caution To assure continued compliance example use only shielded interface cables when connecting to com puter or peripheral devices Any changes or modifications not expressly approved by the party responsible for compli ance could voi...

Page 3: ...one of 16 monitors Remote control of up to 128 cameras and auxiliary equipment by using optional receivers and accessories including 1 Remote control of Pan Tilt Head and Camera Housing 2 Remote control of Motorized Zoom Lenses Focus Zoom and Iris 3 Remote control of camera settings including Electronic Sensitivity Enhancement Electronic Shutter Electronic Zoom and more Selection of various sequen...

Page 4: ... nor try to operate it in wet areas Take immediate action if the appliance becomes wet Turn the power off and refer servicing to qualified ser vice personnel Moisture may damage the appliance and also cause electric shock Do not use strong or abrasive detergents when cleaning the appliance body Use a dry cloth to clean the appliance when it is dirty When the dirt is hard to remove use a mild deter...

Page 5: ...EQ ALT DEC 1CAM INC 1CAM STOP SLOW 1 2 AUX CLOSE OPEN IRIS PRESET FOCUS NEAR ZOOM TELE FAR WIDE System Controller WV CU 550 LEFT RIGHT UP DOWN ALARM BUSY F3 F4 F2 F1 B AF q w e r t y u i o 0 1 2 3 4 5 6 7 1 9 8 0 CONTROLLER ON OFF IN OUT TERM ON OFF DATA 0 1 2 3 4 5 6 7 8 9 CONTROLLER UNIT NO 1 8 MODE 1 2 3 4 5 6 Rear View ...

Page 6: ...the desired camera number with the Numeric keys and then press the CAM key SET This key in combination with the Numeric keys is used to enter numeric input such as operator ID and password It is also used to execute the currently highlighted selection and to enter a submenu in the Setup Menu of the Matrix Switcher 2 Numeric Keys 0 9 These keys are used for numeric input into the system such as the...

Page 7: ...edgment the indicator on the button blinks rapidly and finally press it again for alarm reset the indicator goes off After an alarm acknowledgment pressing this button while the Alternate ALT indicator is on will cancel all currently activated alarms at the same time 1 Data Ports DATA IN OUT Exchanges control data with the WJ SX550B Matrix Switcher in a system 2 Termination Switch TERM ON OFF This...

Page 8: ... Controller by removing four screws 2 Remove the Palm rest located on the front of the System Controller by removing two screws 3 Place the Rack Mounting Brackets on both sides of the System Controller and tighten with the four supplied screws 4 Install the System Controller with Rack Mounting Brackets in the rack by using four screws procured locally Remove screws Tighten screws Rack Mounting Bra...

Page 9: ...o Preset Off Lens Functions Iris Open Close Preset only with DC control lens Focus Near Far Zoom Tele Wide Auto Focus Activate Housing Wiper On Off Defroster On Off Camera On Off Pan Tilt Manual Pan Right Left Manual Tilt Up Down Auto Pan On off Random Pan On Off Preset Home Auxiliary Switch AUX 1 2 On Off Unit Number 1 8 Ambient Operating Temperature 10 C 50 C 14 F 122 F Ambient Operating Humidit...

Page 10: ...et STANDARD ACCESSORY Matrix Switcher WJ SX550B Extension Unit WJ AD550 Video Input Board WV PB5508 Video Output Board WV PB5504A Alarm Board WV PB5564 Data Board WV PB5548 Rack Mounting Bracket WV Q62 Blank Panel WV Q63 MAJOR OPTIONAL UNITS AND ACCESSORIES ...

Page 11: ...onic Security and Digital Imaging Systems Company A Division of Matsushita Electric Corporation of America Executive Office One Panasonic Way 3E 7 Secaucus New Jersey 07094 Regional Offices Northeast One Panasonic Way Secaucus NJ 07094 201 348 7303 Southern 1225 Northbrook Parkway Suite 1 160 Suwanee GA 30024 770 338 6838 Midwest 1707 North Randall Road Elgin IL 60123 847 468 5211 Western 6550 Kat...

Reviews: