background image

Camera

Sun Shade

Dummy cover 
or IR LED unit 
(optional)

Front glass

Wiper

PAN  

rotation part

Mounting 

pedestal

Tilt arm

Tilt lock

Side cover

Waterproof 
EXT I/O 
connector

Waterproof 
RJ45  
connector

Waterproof 
power supply 
connector

Bottom wiring port

Side wiring port*

1

Mounting pedestal 
fixing screws ×4 
(locally procured)

Dummy cover or IR LED unit 
(optional)

IMPORTANT:

• When the camera is initialized, the settings including the network settings will be initialized. Note that the 

CRT key (SSL encryption key) used for the HTTPS protocol and the preset entry will not be initialized.

• Before initializing the settings, it is recommended to write down the settings in advance.
• Do not turn off the power of the camera during the process of initialization. Otherwise, it may 

fail to initialize and may cause malfunction.

STATUS indicator behaviors

• When the power is turned on
  Lights orange 

 Lights off 

 Blinks orange 

 Lights orange (When the network connection is not established)

   Lights  orange 

 Lights off 

 Blinks orange 

 Blinks green 

 Lights green  

(When the network connection is established)

• During the standby or connection
  Lights orange (When the cable is not connected)
  Lights green (When the cable is connected)
• During the upgrade process
  Blinks orange
• During the initialization
   Lights  orange 

 Lights off 

 Blinks orange 

  

Lights orange

• Port forwarding error caused by the UPnP function
   Blinks orange (in 2 seconds intervals  

(on for 1 second / off for 1 second))

• Trouble happening on the camera
  Blinks red
• When the installation position is abnormal
  Lights red

• This manual describes the installation procedures, network camera installation, cable connec-

tions, and adjustment.

• Before reading this manual, be sure to read the Important Information (included in the CD-ROM).

Parts and functions

Standard accessories

Cable preparation

Important safety instructions ......................... 1 pc.
Installation Guide (this document) ................. 1 set

Warranty card*

1

 ............................................ 1 set

CD-ROM*

2

 .................................................... 1 pc.

Code label*

3

.................................................. 1 pc.

Attach the provided waterproof connector to the cable to be connected to the camera.
* When a conduit is used for wiring, always check its size before installing the waterproof connector. 

Otherwise, the cable may not be able to pass through the conduit depending on the number of cables 
used and the waterproof connector in use.

* Always make preparations before the procedure “[3] Attach the waterproof RJ45 connector (acces-

sory) to the Ethernet cable.”

* Prepare [1] and [2] when necessary. 

*1  This product comes with several types of warranties. Each warranty is only applicable to the prod-

ucts purchased in the regions indicated on the relevant warranty.

*2 The CD-ROM contains the operating instructions and different kinds of tool software programs.
*3 This label may be required for network management. The network administrator shall retain the code label.
Waterproof power supply connector (plug side) ...............................................................................1 set
Waterproof EXT I/O connector (plug side) ........................................................................................1 set
Waterproof RJ45 connector (plug side) ............................................................................................1 set
Washer nozzle mounting bracket A ..................................................................................................1 pc.
Washer nozzle mounting bracket B..................................................................................................1 pc.
Fixing screws for the washer nozzle mounting bracket B ..............................3 pcs. (of them, 1 for spare)
Attachment plate .............................................................................................................................1 pc.
Fixing screws for attachment plate ................................................................. 5 pc. (of them, 1 for spare)
Fixing nuts for attachment plate ..................................................................... 5 pc. (of them, 1 for spare)
Spring washer ............................................................................................... 5 pc. (of them, 1 for spare)
Flat washer .................................................................................................. 10 pc. (of them, 2 for spare)
Safety wire .......................................................................................................................................1 pc.
Wire clamper ...................................................................................................................................1 pc.
Bit (Hex wrench, screw size 6.35 mm {1/4 inches} T20)...................................................................1 pc.

Hub/Router

AC100-240 V 
50/60 Hz

Ethernet cable (category 5e or better, straight)

Ethernet cable (category 
5e or better, straight)

PC*

2

Tested PoE injector*

1

Installation procedure

• Attach the provided waterproof connector to the cable to be wired to the inside of the ceiling or 

floor or along various surfaces, and run the cable through the conduit. (Please choose a conduit 
of a suitable size to allow the connector to pass through.)

Cable preparation

• Remove the side cover of the camera so that the wire connection part is visible. (Step.4)
• If necessary, install the extension unit (IR LED unit) (optional) if necessary. (Step.5)
• If you want to shoot the foot area, bend the tilt arm of the camera forward. (Step.6)
• Fix the camera onto the installation location. (Step.8)

* Install the washer nozzle mounting bracket pre-fitted with a (recommended) washer nozzle at the 

same time.

Installation

• Connect each waterproof connector to the camera, and fix the side cover back to its original position.

Connecting wires

(

→ 

Refer to the leaflet “Configuring 

the camera so that it can be 
accessed from a PC”)

• Turn on the power supply, and configure the camera so 

that it can be accessed via network.

Configuring the camera so that it can be accessed from a PC

• About the INITIAL SW (Initial switch)

Follow the steps below to initialize the network camera.

  Cut the power supply to the camera either by unplugging the AC power cord or by turning off the 

power supply of the tested PoE injector.

  Turn on the power of the camera while holding down the INITIAL SW, and keep the INITIAL SW held 

down for 10-15 seconds. In about 2 minutes after releasing the INITIAL SW, the camera will start up 
and the settings, including the network settings, will be initialized.

System connection diagram

The camera can be powered by the AC power supply or the tested PoE injector as shown in the follow-
ing illustration.

*1  For the related information on applicable tested PoE injectors, refer to our website  

(http://security.panasonic.com/support/info/).

*2  Use an Ethernet cable (category 5e or better, cross) when directly connecting the camera to a PC.

*1  The female thread for conduit is compliant with ANSI NPSM (parallel pipe threads) 3/4 or 

ISO 228-1 (parallel pipe threads) G3/4.

[1] Attach the waterproof EXT I/O connector (accessory) to the cable

* The parts to be used in 

 and 

 are in the bag of the waterproof EXT I/O connector (plug side) set.

<Locally procured items>

  • Multi-core cable 

ø6.2 ~ 7 mm {ø1/4 ~ 9/32 inches}

 

Size of the internal lead wire 

AWG26 – AWG30, coated external diameter of ø1 mm {ø1/32 inches} or below

  • Manual crimping tool 

HT-102/HR30-1, made by Hirose Electric Co., Ltd.

  • Extraction tool (if necessary) 

HR30-TP, made by Hirose Electric Co., Ltd.

  

Thread each part of the waterproof EXT I/O connector (accessory) through the cable in 
sequence

  Pass the cord tube, cord clamp, gasket, spring and coupling in sequence through the plug beforehand. 

Prepare wire ends according to the dimensions shown in the illustration below.

Case block

Coupling

Spring

Cord clamp

Gasket

Cord tube

Cable

15 ~ 20 mm {19/32 ~ 25/32 inches}

2.0 mm (+0, -0.5)  
{3/32 (+0, -1/32) inches}

  

Crimp the contact (accessory) to the cable

  

Insert the contact into the terminal hole on the 
case block

 

• After inserting the contact, pull the lead wire lightly, 

and ensure that it is firmly fixed to the terminal hole 
of the waterproof EXT I/O connector.

<Pin layout of the waterproof EXT I/O connector>

Pin. 1  LINE IN

Pin. 7 

Alarm IN1

Pin. 2  Audio/LINE_GND

Pin. 8 

N.C.

Pin. 3  Audio OUT

Pin. 9 

Relay-

Pin. 4  Alarm GND

Pin. 10  Relay-

Pin. 5  Alarm IN3/AUX

Pin. 11  Relay+

Pin. 6  Alarm IN2/Alarm OUT

Pin. 12  Relay+

 

 Mount the coupling and the spring on the case block, and tighten the cord tube with the gasket 
and the cord clamp

•  Align the mark “

” on the coupling 

with the side of pin 

 of the case block, 

and install the coupling and the spring in 
sequence.

•  Shift the cord tube, and insert the cord 

clamp and the gasket in the cord tube.

•  Align the cord tube with the coupling part, 

and rotate to tighten them as shown in the 
right illustration. (Recommended tightening 
torque: 0.5 N·m {0.37 lbf·ft})

 

Connect the washer unit (locally procured)

Pin. 9 

Relay-

Pin. 10  Relay-
Pin. 11  Relay+
Pin. 12  Relay+

Waterproof EXT I/O 
connector side

Circuit diagram

Washer unit connection 
terminal side

Washer-

Nozzle

Washer hose

* Please use the washer unit that has been insulated from the commercial AC power.

 

EXT I/O terminal ratings

 •  Alarm IN1, Alarm IN2, Alarm IN3
  Input specification: No-voltage make contact input (4 V ~ 5 V DC, internally pulled up)
 

OFF: Open or 4 V ~ 5 V DC

 

ON: Make contact with GND (required drive current: 1 mA or more)

 •  Alarm OUT, AUX OUT
  Output specification: Open collector output (maximum applied voltage: 20 V DC)
 

OPEN: 4 V ~ 5 V DC by internal pull-up

 

CLOSE: Output voltage 1 V DC or less (maximum drive current: 50 mA)

 •  Max. ratings of Relay+ and Relay-: DC 25 V, 4.0 A
 *  The default of EXT I/O terminals is “Off”.

[2] Attach the waterproof power supply connector (accessory) to the cable

* The parts to be used in 

 and 

 are in the bag of the waterproof power supply connector (plug side) set.

<Locally procured items>

 

• Power cable 

 

Cable diameter 

ø6 ~ 10 mm {ø1/4 ~ 13/32 inches}

 

Cross-sectional area of the wire conductor 

0.75 or 1.25 mm

{0.0012 or 0.0019 inche

2

}

 

Number of wires 

3 (for L, N and FG)

 

Insulation material 

Polyethylene (recommended)

 

Preparations

 

• Assemble the internal strain relief as shown in the right illustration, 

and install the fixing bracket.

     (Tighten the screws temporarily as the power cord will go in between 

the bracket and the formed part.)

  • Install the mounting gasket on the clamp 

ring as shown in the right illustration. (Please 
use the applicable parts as described below 
for the mounting gasket according to the 
external diameter of the power cord.)

     Small internal diameter... 

Power cord size  6.0 ~ 9.0 mm {1/4 ~ 11/32 inches}

     Large internal diameter... 

Power cord size  9.0 ~ 10.0 mm {11/32 ~ 13/32 inches}

 

Thread each part of the waterproof power supply connector through the power cable in 
the sequence as shown in the illustration below

 

• Cable nut 

 Clamp ring (with mounting gasket) 

 Back shell 

 Internal strain relief

Internal strain relief

Back shell

Clamp ring (with 
mounting gasket)

Cable nut

Cable

  Prepare the cable end in the following dimensions, and twist the core.  

Process tolerance: +1 mm/-0 mm {+1/32 / -0 inches}

Dimensions A (cable sheath) Dimensions B (bare core wire)

Live, Neutral 18 mm {23/32 inches}

7 mm {9/32 inches}

GND

20 mm {25/32 inches}

9 mm {11/32 inches}

 

While the core of the lead wire is inserted into the connecting hole at the back of the 
connector body, tighten the screw on the connector body, and connect 
and fix the lead wire to each terminal. 
For safety purpose, please read the following connection instructions carefully.

* There is a cutout on the connector coupling nut.

 

Align the position of the screw to be tightened with the cutout on the coupling 
nut, and tighten the screw with a flathead screwdriver. (Refer to the upper 
right illustration.)  
(Recommended tightening torque: 0.5 N·m {0.37 lbf·ft}

During fore position

During upright position

Clamp ring

Mounting 
gasket

Small internal 
diameter

Large internal 
diameter

Case block

Waterproof EXT I/O connector (accessory)
Terminal layout of the contact insertion side

  

 Connector Pin 

1 Live  

 Pin 

2 Neutral  

 Pin 

3 N.C.  

   GND

Cutout

Coupling nut

Pin 2

Pin 1

Pin 3

GND

 

Insert and fix the internal strain relief on the connector as shown in the illustration. Next, 
rotate the screw of the internal strain relief, and fix the power cord firmly with the fixing 
bracket.

(Recommended tightening torque: 0.5 N·m {0.37 lbf·ft})

 

Align the coupling nut to the fixing position to prevent 
the connector from rotating, and rotate to fix the back 
shell. Install the clamp ring (with mounting gasket) on 
the back shell, and tighten it with a cable nut. 

(Recommended tightening torque: 1.5 ~ 2.0 N·m {1.11 ~ 1.48 lbf·ft}

Coupling nut

Back shell

Cable nut

Clamp ring
(with mounting gasket)

Screws × 2

Internal strain relief

Internal strain 
relief (accessory)

Fixing bracket 
(accessory)

Screws x 2 
(accessory)

Pin 

Coupling

Spring

Cord tube (Including the cord clamp and the gasket)

Case block

Installation Guide

Included Installation Instructions

Network Camera

Model No.

 

WV-SUD638

WV-SUD638-H / WV-SUD638-T

(Natural silver)

(Gray)

(Brown)

fles0816-1057  PGQX2063YA  Printed in China 

For U.S. and Canada:

Panasonic System Communications 

Company of North America,

Unit of Panasonic Corporation

of North America

www.panasonic.com/business/

For customer support, call 1.800.528.6747

Two Riverfront Plaza, Newark, NJ 07102-5490

Panasonic Canada Inc.

5770 Ambler Drive, Mississauga,

Ontario, L4W 2T3 Canada 

(905)624-5010

www.panasonic.ca 

For Europe and other countries:

Panasonic Corporation

http://www.panasonic.com

Panasonic Corporation  

Osaka, Japan

Authorised Representative in EU:

Panasonic Testing Centre

Panasonic Marketing Europe GmbH

Winsbergring 15, 22525 Hamburg, Germany

© Panasonic Corporation 2017

Switch plate

STATUS indicator

ACT Indicator

LINK indicator

INITIAL SW 

(Initial switch)

a

b

Connector body

2

4

3

5

7

6

8

56789

Reviews: