![Panasonic WV-PB5564E Instructions Download Page 2](http://html.mh-extra.com/html/panasonic/wv-pb5564e/wv-pb5564e_instructions_278094002.webp)
BOARD
NO.
Pin No.
Pin No.
-2-
(Close) Alarm Sensor
(Open) Alarm Sensor
Normal Condition
Alarm In
Alarm Signal
Normally Open
(NOR OPEN)
t
100 msec.
Normally Closed
(NOR CLOSE)
(Close) Alarm Sensor
(Open) Alarm Sensor
t
100 msec.
t
0V
0V
t
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
Alarm 1(65)
Alarm 2(66)
Alarm 3(67)
Alarm 4(68)
Alarm 5(69)
Alarm 6(70)
Alarm 7(71)
Alarm 8(72)
Alarm 9(73)
Alarm 10(74)
Alarm 11(75)
Alarm 12(76)
Alarm 13(77)
Alarm 14(78)
Alarm 15(79)
Alarm 16(80)
Alarm 17(81)
Alarm 18(82)
Alarm 19(83)
Designation
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
Pin No.
Alarm 20(84)
Alarm 21(85)
Alarm 22(86)
Alarm 23(87)
Alarm 24(88)
Alarm 25(89)
Alarm 26(90)
Alarm 27(91)
Alarm 28(92)
Alarm 29(93)
Alarm 30(94)
Alarm 31(95)
Alarm 32(96)
Not used
Not used
Not used
Ground
Ground
Designation
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
Alarm 33(97)
Alarm 34(98)
Alarm 35(99)
Alarm 36(100)
Alarm 37(101)
Alarm 38(102)
Alarm 39(103)
Alarm 40(104)
Alarm 41(105)
Alarm 42(106)
Alarm 43(107)
Alarm 44(108)
Alarm 45(109)
Alarm 46(110)
Alarm 47(111)
Alarm 48(112)
Alarm 49(113)
Alarm 50(114)
Alarm 51(115)
Designation
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
Pin No.
Alarm 52(116)
Alarm 53(117)
Alarm 54(118)
Alarm 55(119)
Alarm 56(120)
Alarm 57(121)
Alarm 58(122)
Alarm 59(123)
Alarm 60(124)
Alarm 61(125)
Alarm 62(126)
Alarm 63(127)
Alarm 64(128)
Not used
Not used
Not used
Ground
Ground
Designation
1-32
37
20
19
1
33-64
37
20
19
1
1
2
OFF
1
2
OFF
1
2
1-64
65-12
ALARM
INPUT NO.
SW1 SETTING
BOARD SETTING
Before installing this board, the following settings should be made by qualified service personnel or system installers.
1. Set switches (SW1) on the board to meet the alarm input number as shown below.
1
2
OFF
SW1
UNIT ADR
5.
Alarm Input Connector (1-32, 33-64)
This connector accepts the alarm signals, either normally open or normally closed, from the associated alarm sensor unit.