14
m
Adjust the focus position.
Loosen the flange-back lock screw and rotate the flange-back adjustment ring to adjust the
focus position while monitoring the video monitor. When completing the adjustment, tighten
this screw.
Recommended tightening torque: 0.05 N·m {0.5 k
g
f·cm}
Important:
• When the screw is tightened stronger than the recommended tightening torque, it may
strip the thread or cause focus misalignment.
Notes:
• When using a fixed-focal lens featuring the focus adjustment, adjust the flange-back
length after setting the lens focus to the FAR end.
• When using a vari-focal lens featuring the focus adjustment, refer to the operating
instructions of the lens in use.
n
Bundle the coaxial cable and the power cord onto the camera mount bracket with cable
ties (procured locally).
Important:
• When bundling the cables with cable ties, cable ties with enough tolerable intensity
and durability should be used, such as metal cable ties, as a coaxial cable may have
to support the camera if it falls from the camera mount bracket.
Camera mount bracket
(option)
Example:
Ceiling mount
installation
Bundle the cables and fix
them onto the camera
mount bracket firmly.
Camera mount bracket
(option)
Example:
Wall mount
installation
Bundle the cables and fix
them onto the camera
mount bracket firmly.
Summary of Contents for WV-CP280 Series
Page 33: ...33 ...
Page 49: ...49 ...
Page 65: ...65 ...
Page 81: ...81 ...
Page 101: ...101 目 录 重要安全须知 99 有限责任 100 免责条款 100 前言 102 注意事项 102 各部分的名称和功能 104 安装和连接 107 规格 111 附件 111 ...
Page 112: ...112 在欧盟以外其它国家的废物处置信息 此符号仅在欧盟有效 如果要废弃此产品 请与当地机构或经销商联系 获取正确的废弃方法 ...
Page 113: ......