25
w
Reinstall the dome cover fixing screw.
Important:
• Attach the inner dome in accordance with the lens direction to not to change the lens direction.
• Check if the tabs of the inner dome are firmly fit.
• Remove the cushioning (pink sheet) from the inside of the dome and the protection sheet from
the outside of the dome.
Note:
• Defocus may be caused by the reinstalled dome cover. When using a system controller (option),
adjust the back-focus on the setup menu after attaching the dome cover. (
+
Operating Instruc-
tions (PDF))
• When not using a system controller, by using the [ABF2] button back-focus adjustment is avail-
able after attaching the dome cover. The procedure for the use of the [ABF2] button is as spec-
ified below.
q
Press the [ABF2] button.
→
The ABF operation indicator will start blinking.
w
While the indicator is blinking (for around 3 minutes), attach the dome cover to the camera.
e
When the indicator changes to steady light, back-focus will be adjusted automatically. After
the back-focus is adjusted, the indicator will go out.
* Do not aim the camera to objects continuously moving.
* If the indicator blinks again after changing to steady light, back-focus adjustment may have
failed. In this case, check the back-focus on the LCD monitor.
To adjust the back-focus again, perform Step
q
to
e
again.
Dome cover fixing screw
(M3, step screw)