
Mounting
© Panasonic Industrial Devices SUNX Co., Ltd. 2016
34
Step 3 While pushing the product against the hexagon-socket head bolt side, mount the no
dead-space beam adjustment mounting bracket. Make sure the slot in the product is
locked onto the tab on the no dead-space beam adjustment mounting bracket.
This device
Hexagon-socket head bolt
No dead-space beam adjustment
mounting bracket
Slot
Tab
Check if locked
CAUTION
●
Do not mount the no dead-space beam adjustment mounting bracket on the cap (black part) of
the product.
● In step 3, the product is not yet fastened. If you do not maintain a firm grip on the product, it may
fall and cause injury or product damage.
Step 4 Fasten with the hexagon-socket head bolt (M5, black) for light curtain fastening.
Tighten to a torque of 2N·m or less.
Hexagon-socket head bolt
for light curtain fastening
(M5, black)
This device
CAUTION
Firmly fasten the product to the no dead-space beam adjustment mounting bracket. Risk of prod-
uct falling and causing injury or product damage.
Summary of Contents for WUME-SF4D-2
Page 2: ... Panasonic Industrial Devices SUNX Co Ltd 2016 2 MEMO ...
Page 126: ...Functions Panasonic Industrial Devices SUNX Co Ltd 2016 126 MEMO ...
Page 130: ...Maintenance Panasonic Industrial Devices SUNX Co Ltd 2016 130 MEMO ...
Page 172: ... Panasonic Industrial Devices SUNX Co Ltd 2016 172 MEMO ...