89
FEB 2008
Ver. 1.1
DP-C405/C305/C265
The SD Memory Card is now ready to use for firmware update.
(Refer to the SD Memory Card Firmware Writing Tool Readme File.)
2.11.6.
Notice after installing the HDD option
After the Hard Disc Drive Unit is installed, to prevent a Disc Scan Function from being performed (similar
to when the power is abruptly interrupted to the PC), it is important to follow the step sequence below
when turing OFF the Power Switches on the machine.
1. Turn the Power Switch on the left side of the machine to the
OFF ( )
position first.
2. Wait approximately 10 seconds while the machine writes the closing status onto the Hard Disc Drive
Unit.
3. Turn the Main Power Switch on the back of the machine to the OFF position.
2.11.7.
Firmware Emergency Recovery
The easiest method to recover the firmware in an Emergency Recovery routine is to use the Master SD
Memory Card method. (Even the Master SD Memory Card includes all necessary firmware as a
package, only SC PCB Firmware can be recovered.)
If the unit does not boot up properly, follow the steps below:
1. Turn the power OFF.
Before proceeding to the next step, you must create the Master SD Memory Card (read the section
2.11.5. first).
2. Turn the power On while holding the
“Energy Saver”
key.
3. When the message
“Selected Emergency Firmware Update”
is on the LCD display, release the
“Energy Saver”
key.
During the recovery mode, the LCD displays
“Reading SC Firmware”
,
“Writing SC Firmware”
,
and
“SC Firmware updated has been completed”
. Then the machine reboots itself, and returns
to the standby mode.
After the SC Firmware recovering, if other firmware for EC, FCB, SCN PCBs, and PS option are
required, use the Master SD Memory Card to update the firmware by selecting the
“Auto Mode”
to the
required level. Refer to Section 2.11.4. (Updating the Firmware using the Master Firmware SD Memory
Card).
Note:
After the SC Firmware recovers, if the Error Code E5-12 or E5-13 is displayed, use the Master SD
Memory Card to update the firmware selecting the required firmware, EC, SCN, FCB or PS, refer to
Section 2.11.4.
In this case, the Network update method can not be used.
Summary of Contents for Workio DP-C265
Page 2: ...2 ...
Page 3: ...3 ...
Page 5: ...5 ...
Page 6: ...6 For PB and Other destinations not for PU USA Canada ...
Page 11: ...11 ...
Page 12: ...12 ...
Page 13: ...13 ...
Page 14: ...14 memo ...
Page 94: ...94 FEB 2008 Ver 1 1 DP C405 C305 C265 Color Test Chart 101 P N PJQRC0119Z LDR PJQRC0120Z A3 ...
Page 106: ...106 FEB 2008 Ver 1 1 DP C405 C305 C265 2 20 720K PM Kit DQ M35S72 DQ M32N72 ...
Page 274: ...274 FEB 2008 Ver 1 1 DP C405 C305 C265 LVPS CN6 LVPS CN7 Refer to SCN PC Board ...
Page 275: ...275 FEB 2008 Ver 1 1 DP C405 C305 C265 LVPS CN8 Europe Specification Only ...
Page 278: ...278 FEB 2008 Ver 1 1 DP C405 C305 C265 CST PCB CN603 CST PCB CN604 ...
Page 279: ...279 FEB 2008 Ver 1 1 DP C405 C305 C265 CST PCB CN605 ...
Page 280: ...280 FEB 2008 Ver 1 1 DP C405 C305 C265 ...
Page 281: ...281 FEB 2008 Ver 1 1 DP C405 C305 C265 CST PCB CN606 ...
Page 282: ...282 FEB 2008 Ver 1 1 DP C405 C305 C265 ...
Page 283: ...283 FEB 2008 Ver 1 1 DP C405 C305 C265 CST PCB CN607 ...
Page 284: ...284 FEB 2008 Ver 1 1 DP C405 C305 C265 CST PCB CN608 ...
Page 286: ...286 FEB 2008 Ver 1 1 DP C405 C305 C265 TRU PCB CN613 ...
Page 288: ...288 FEB 2008 Ver 1 1 DP C405 C305 C265 RLB PCB CN176 ...
Page 682: ...682 FEB 2008 Ver 1 1 DP C405 C305 C265 memo ...
Page 738: ...738 FEB 2008 Ver 1 1 DP C405 C305 C265 memo ...
Page 808: ...519 E ...