Panasonic Whisper Wall FV-08WQ1 Installation Instructions Manual Download Page 3

3

Dimensions

Main unit

Wall sleeve

Exterior hood

A

D

E

B

C

1

2

3

4

5

6

K

F

J

G

11

8

9

10

7

I

M

L

P

13

12

Q

S

O

N

R

4-5 dia. hole

4-5 dia. hole

Unit: mm (inch)

15

14

H

Extension sleeve

No.

Part name

1

Grille

2

Frame

3

Blade

4

Motor

5

Connector

6

Hook

7

Flange

8

Duct

9

Junction box

10

Junction box cover

11

Connector

12

Shutter

13

Duct

14

Spring

15

Bird screen

T

U

A

B

C

D

E

F

260

52

88

2

173ø

 250

(10-1/4 ) (2-1/16) (3-15/32)

(3/32)

(6-13/16ø) (9-27/32 )

G

H

I

J

K

L

115

203

240

230

230

260

(4-17/32)

(8)

 (9-7/16) (9-1/16)

(9-1/16)

(10-1/4 )

M

N

O

P

Q

R

204ø

50

50

150

230

240

(8-1/32ø) (31/32)

(31/32)

(5-29/32)

(9-1/16)

(9-7/16)

S

T

U

240

207

127

(9-7/16) (8-5/32)

(5)

Summary of Contents for Whisper Wall FV-08WQ1

Page 1: ...uld result in personal injury and or property damage Please retain for future reference Table of Contents Pages List of components 2 Description 2 Reference installation drawing 2 Dimensions 3 Specifications 4 Unpacking 4 General safety precautions 4 Installation I In new construction 5 6 Installation II In remodeling 7 8 Maintenance 9 10 Product Service 10 FV 08WQ1 Ventilating Fan Through the Wal...

Page 2: ... designed for extended service life with reduced energy consumption It also incorporates a thermal cutoff device for safety The grille is easily detachable from the main unit Interior wall Wall thickness 114 3 152 4 mm 4 5 6 No extension sleeve is used Quantity 1 4 1 2 Quantity 1 1 1 1 Exterior wall Exterior hood Outdoor Flexible conduit Wall sleeve Connector Main unit Indoor When the wall thickne...

Page 3: ...3 Blade 4 Motor 5 Connector 6 Hook 7 Flange 8 Duct 9 Junction box 10 Junction box cover 11 Connector 12 Shutter 13 Duct 14 Spring 15 Bird screen T U A B C D E F 260 52 88 2 173ø 250 10 1 4 2 1 16 3 15 32 3 32 6 13 16ø 9 27 32 G H I J K L 115 203 240 230 230 260 4 17 32 8 9 7 16 9 1 16 9 1 16 10 1 4 M N O P Q R 204ø 50 50 150 230 240 8 1 32ø 31 32 31 32 5 29 32 9 1 16 9 7 16 S T U 240 207 127 9 7 1...

Page 4: ...rify that all parts were supplied 1 At 0 0 Static pressure Pa 2 For main unit only WARNING To reduce the risk of fire electric shock or injury to persons observe the following A Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer B Installation work and electrical wiring must be done by qualified person s in accordance with all applicabl...

Page 5: ...1 Exterior wall Stud 8 1 2 diameter Wiring Diagram 2 Adjust position of the flange on the wall sleeve Fig 2 Loosen the three screws arrow pointed and slide the wall sleeve horizontally to adjust its position to compensate for the thickness of the interior wall A When this has been done tighten all three screws 3 After providing a 3 mm notch in the wall stud secure the flange to the wall stud with ...

Page 6: ...stallation I In new construction continue Fig 7 Fig 8 Grille Fan unit Frame 7 Insert the attached exterior hood from the outside to cover the wall sleeve and secure it with four screws or nails Cover the seam between the wall sleeve and exterior hood with aluminum tape and apply mortar or caulking around the exterior hood flange to prevent rainwater from coming in Fig 5 Fig 6 Interior wall materia...

Page 7: ...ring through the wall using a flexible con duit 3 Remove the junction box from the wall sleeve by remov ing two screws C Fig 11 4 Remove the junction box cover by removing screw B 5 Remove the screws D and replace the wall sleeve flange with the mounting flange The mounting plate face should align with the end of the wall sleeve which is protruding from indoor side Installation II In remodeling CA...

Page 8: ...sition in the wall sleeve and reattach the box cover Fig 15 Installation II In remodeling continued Fig 15 Fig 14 Flexible conduit CAUTION Reattach the junction box cover carefully so that the lead wires are not pinched by the cover Motor White Black Red Green Junction box Power supply AC 120 V 60 Hz Green Earth ground Fig 13 Exterior hood Finish with mortar or caulk Fig 16 CAUTION Press on the gr...

Page 9: ...ent 3 Do not immerse resin parts in water with temperature higher than 140o F 60o C 1 Remove the grille Hold the grille and press the hooks on each side simultaneously Pull the grille straight out from the wall Fig 17 2 Wash and clean the grille Use non abrasive kitchen de tergent Wipe it dry with a clean cloth Fig 18 Fig 17 Grille Fig 18 3 Remove dust and dirt from the fan blades and body us ing ...

Page 10: ...roduct is designed and manufactured to ensure a minimum of maintenance However should your unit ever require service a nation wide system of factory service centers and AUTHORIZED INDEPENDENT SERVICE CENTER is maintained to support your product s warranty In the U S A call 1 800 545 2672 to locate the PASC Authorized Service Center nearest you Fig 20 Maintenance continued Blade Fan unit Frame PANA...

Reviews: