Operating conditions
HEATING (CIRCUIT)
*
1,
*
2
COOLING (CIRCUIT)
Water outlet temperature (°C) (Min. / Max.)
20 / 55 (Below Ambient -15 °C) *
3
20 / 60 (Above Ambient -10 °C) *
3
5 / 20
Outdoor ambient temperature (°C)
(Min. / Max.)
-20 / 35
10 / 43
When the outdoor temperature is out of the range in the table, the heating capacity will drop signi
fi
cantly and the outdoor unit may
stop operating for its protection.
The unit will restart automatically after the outdoor temperature returns to the speci
fi
ed range.
*
3
Between outdoor ambient -10 °C and -15 °C, the water outlet temperature gradually decreases from 60 °C to 55 °C.
Before use, make sure the system has been installed correctly by an
authorised dealer according to the given instructions.
•
Panasonic Air-to-Water Heatpump
is a split system, consisting of two units: indoor and outdoor units. This system is designed
to operate with Panasonic Water Tank Unit. Unless used together with the Panasonic Water Tank Unit, Panasonic does not
guarantee any normal operation nor the reliability of the system.
•
These operating instructions describe how to operate the system using the indoor and outdoor units.
•
As for the operation of other products such as water tank, radiator, external thermo controller, and under
fl
oor units, refer to the
operating instructions of each product.
•
System could be locked to operate in HEAT mode and disable COOL mode.
•
Some functions described in this manual may not be applicable to your system.
•
Consult your nearest authorised dealer for further information.
*
1
The system is locked to operate without COOL mode. It can be unlocked only by authorised installers or our authorised service
partners.
*
2
Only displayed when COOL mode is unlocked (This means when COOL mode is available)
Outdoor
Unit
Power Supply
Solar Panel
Radiator
Shower
Fan Coil
Unit
Floor
Heating
Water Tank Unit
Indoor Unit
Remote Controller
The illustrations in this manual are for explanation purposes only and may differ from the actual unit.
They are subject to change without notice for future improvement.
System overview
3