English
19
Menus
Menu
Default Setting
Setting Options / Display
Sterilization
Monday
Sterilization may be
set for 1 or
more days of the
week.
Sun / Mon / Tue /
Wed / Thu / Fri / Sat
Sterilization: Time
12:00
Time of the selected
day(s) of the week to
sterilize the tank
0:00 ~ 23:59
Sterilization: Boiling temp.
65 °C
Set boiling
temperatures for
sterilize the tank.
Sterilization: Ope. time (max)
0:10
Set sterilizing time
(in hours and minutes)
7 Installer
setup Service setup
7.1
Pump maximum speed
To set the maximum speed of
the pump.
Setting the flow rate, max. duty and operation
ON/OFF of the pump.
Flow rate: XX:X L/min
Max. Duty: 0x40 ~ 0xFE,
Pump: ON/OFF/Air Purge
7.2
Pump down
To set the pump down
operation.
Pump down operation
ON