Item
Unit
Indoor Unit
Hot Water Coil
Type
Brazed Plate
No. of Plates
48
Size (H × W × L)
mm
82 × 93 × 325
Water Flow Rate
l/min (m
3
/h)
Cooling: 20.1 (1.2)
Heating: 25.8 (1.5)
Pressure Relief Valve Water Circuit
kPa
Open: 300, Close: 266 and below
Flow Switch
Electronic Sensor
Protection Device
A
Residual Current Circuit Breaker (30 ~ 40)
Expansion Vessel
Volume
I
10
MWP
bar
3
Capacity of Integrated Electric Heater
kW
3.00
Note:
Cooling capacities are based on outdoor air temperature of 35°C Dry Bulb with controlled indoor water inlet
temperature of 12°C and water outlet temperature of 7°C.
Heating capacities are based on outdoor air temperature of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb
(42.8°F Wet Bulb) with controlled indoor water inlet temperature of 30°C and water outlet temperature of 35°C.
Specification are subjected to change without prior notice for further improvement.
Flow rate indicated are based on nominal capacity adjustment of leaving water temperature (LWT) 35°C and
∆
T
= 5°C.