45
9. Electronic Circuit Diagram
9.1 Indoor
Unit
ELECTRONIC CONTROLLER
(MAIN)
POOL
W
ATER PUMP
SOLAR W
ATER PUMP
ERROR SIGNAL
WA
TE
R
P
U
M
P
ZONE 1
WA
TE
R
P
U
M
P
ZONE 2
ROOM TEMP.
ZONE 2
ROOM TEMP.
ZONE 1
BUFFER TANK
SENSOR
COOL
HEA
T
N
L
ROOM THERMO
2
COOL
HEA
T
N
L
ROOM THERMO
1
CLOSE
OPEN
N
MIXING VA
LVE 1
OPEN
N
CLOSE
MIXING VA
LVE 2
CN205
CN209
CN201
CN202
CN203
CN208
POOL TEMP.
SENSOR
WATER TEMP.
ZONE 2
WATER TEMP.
ZONE 1
CN204
SG SIGNAL
CN206
HEAT/COOL
SWITCH
EXTERNAL
COMP. SW
CN210
CN1
CN3
DEMAND
SENSOR
SOLAR TEMP.
SENSOR
CN207
DC
DC
GND
10V
VCC
BIT2
BIT1
RY
1
SSR203
SSR200
SSR202
SSR201
SSR204
SSR205
SSR206
SSR207
SIGNAL
DETECTION
CIRCUIT
SIGNAL
DETECTION
CIRCUIT
ACN (WHT)
ACL
(BLK)
DCN (BLU)
DCP
(RED)
CN-CNT (WHT)
1
5
CN-COMM
(YL
W
)
1
1 2
4
1
3
2
CN-PWR202
(YL
W)
CN-PWR204
(YL
W)
CN-PWR4
(BLK)
CN-PWR (BLK)
CN-PWR2
(BLU)
CN-CNT (WHT)
CN-PWR3
(GRN)
5 4
1
3 2
1 2
1
3
2
5V_2
1
3
1
CN-PUMP1
(WHT)
W
BL
B
BR
R
W
BL
B
BR
R
1
4
7
6
5
7
4
1
2
3
7
4
1
2
3
M
W
ATER PUMP
G
W
ATER
PIPING
CONNECTING
BAR
W
ATER PUMP
CIRCUIT
G
G02 (GRN)
G
R
1 (BL) 2 (W) 3 (R)
GROUNDING
GROUNDING
TO
OUTDOOR UNIT
TERMINAL
BOARD
(L)
(N)
BL
W
RCCB/ELCB
POWER SUPPLY 1
Single phase AC230V 50Hz
230V 30A~40A
l∆n=30mA
W
BL
DA
TA
(RED)
G01 (GRN)
AC1-N (WHT)
AC1-L3 (BLK)
FUSE 1
T6.3A
L250V
COMMUNICA
TION
CIRCUIT
FUSE 3
T3.15A
L250V
NOISE FIL
TER
CIRCUIT
NOISE FIL
TER
CIRCUIT
WW
WW
REA
TOR
21
21
RECTIFICA
TION
CIRCUIT
NOISE FIL
TER
CIRCUIT
L2
(WHT)
L1
(WHT)
GB
L
BL
BL
BL
RR
W
W
W
G03 (GRN)
RECTIFICA
TION
CIRCUIT
SW1
SW2
2
2
1
1
HT1-L3 (RED)
AC2-L3 (BLK)
AC2-N2 (WHT)
ACL3 (BLK)
RY-HT
(L3)
SIGNAL
DETECTION
CIRCUIT
OLP
80±3°C
RY-BOOSTER
GROUNDING
(L
1
)
(N
1
)
BL
RCCB/ELCB
POWER SUPPLY 2
Single phase AC230V 50Hz
230V 30A~40A
l∆n=30mA
A
B
TERMINAL
BOARD
2-W
AY
VA
LV
E
CN2
CLOSE
OPEN
N
HEA
T
N
COOL
L
RY-V2
3-W
AY
VA
LV
E
ROOM THERMO
1
CLOSE
OPEN
N
RY-V3
CN4
BOILER CONT
ACT
EXTRA
PUMP
RY
-C
O
N
TA
C
T1
BOOSTER HEA
TER
EXTERNAL CONTROL
1
CN5
OUTDOOR AIR SENSOR
TA
N
K
SENSOR
CN6
OLP
BOOSTER
HEA
TER
ROOM TEMP
.
ZONE 1
SSR1
SIGNAL
DETECTION
CIRCUIT
BACKUP
HEA
TER (3kW)
CONTROL
PA
N
EL
BL
1
2
3
4
BL
CN-TH1 (WHT)
1
6
5
4
3
2
FLOW SENSOR
CN-FL
WSEN
(WHT)
1 2 3 4
1
4
B BL
BR W
W
ATER OUTLET
TEMP
. SENSOR (THERMIST
O
R)
CN-TH3 (WHT)
1 2
HEX W
ATER OUTLET
TEMP
. SENSOR (THERMIST
O
R)
t°
t°
REFRIGERANT
TEMP
. SENSOR (THERMIST
O
R)
t°
W
ATER INLET
TEMP
. SENSOR (THERMIST
O
R)
t°
ELECTRONIC CONTROLLER
(SUB)
OPTIONAL
W
W
W W
W
W
W
B
R
BL
W
W
20V
R81 10k
R86 10k
C63 1000p 50V
C61 1000p 50V
5V
OLP
80±3°C
CN-OLP1 (WHT)
1 2
B
B
12V
*R
Y-
HTL3
C93 100p 50V
C123 1μ 50V
ZD2 20V
A
K
LF3
R1 10k
C121 1μ 50V
C83 0.1μ 16V
C89 1μ 16V
C98 1μ 16V
G2
G2
G2
R136 1k
R141 6.49k 1%
12V
5V
5V
R143 6.49k 1%
5V
C92 0.1μ 16V
R130 10k
5V
C91 220μ 10V
C88 1μ 16V
R140 20k 1%
R139 20k 1%
R128 20k 1%
R132 820 1%
R135 20k 1%
G2
G2
G2
C90 1μ 16V
C84 1μ 16V
C81 1μ 16V
C73 1μ 16V
C79 1μ 16V
G6