107
16.5.32 Outdoor Current Transformer Open Circuit (F46)
Malfunction Decision Conditions:
A current transformer (CT) open circuit is detected by checking the compressor running frequency ( rated
frequency) and CT detected input current (< 0.65 A) for continuously 20 seconds.
Malfunction Caused:
1 CT
defective.
2 Faulty outdoor unit PCB (main).
3 Compressor defective (low compression).
Abnormality Judgment:
Continue 3 times in 20 minutes.
Summary of Contents for WH-SDC03E3E5 Series
Page 12: ...12 4 Location of Controls and Components 4 1 Indoor Unit 4 1 1 Location of Control ...
Page 13: ...13 ...
Page 14: ...14 ...
Page 15: ...15 4 1 2 Weekly Timer Setting ...
Page 16: ...16 4 1 3 Setting Up the Special Functions ...
Page 17: ...17 4 1 4 Main Components 4 2 Outdoor Unit ...
Page 18: ...18 5 Dimensions 5 1 Indoor Unit ...
Page 19: ...19 5 2 Outdoor Unit ...
Page 21: ...21 ...
Page 22: ...22 7 Block Diagram ...
Page 23: ...23 8 Wiring Connection Diagram 8 1 Indoor Unit ...
Page 24: ...24 8 2 Outdoor Unit ...
Page 25: ...25 9 Electronic Circuit Diagram 9 1 Indoor Unit ...
Page 26: ...26 9 2 Outdoor Unit ...
Page 27: ...27 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Page 28: ...28 10 1 2 Solar Printed Circuit Board Optional ...
Page 29: ...29 10 2 Outdoor Unit 10 2 1 Main Printed Circuit Board ...
Page 43: ...43 ...
Page 49: ...49 ...
Page 50: ...50 ...
Page 60: ...60 ...
Page 110: ...110 17 3 To Remove Pressure Gauge 17 4 To Remove Control Panel ...
Page 111: ...111 17 5 To Remove RCCB 17 6 To Remove Transformer and Electronic Controller Board ...