35
Menu
Default Setting
Setting Options / Display
5.21
External meter
To set which external meter
to be used depends on meter
connection.
There are generation
meters and various types of
electricity meters.
For generation meters,
there are two connection
systems :-
a) One generation meter
system :
Heat-cool meter only
b) Two generation meter
system :
Heat-cool meter and Tank
meter
Heat-cool meter : No
* Tank meter : No
Elec. meter HP : No
Elec. meter 1 (PV) : No
Elec. meter 2 (Building) : No
Elec. meter 3 (Reserve) : No
* Only available when Heat-cool meter select
Yes
External meter
Heat-Cool meter
Elec. meter 1 (PV)
Select
Confirm
Elec. meter HP
Tank meter
10:34am,Mon
External meter
Elec. meter HP
Elec. meter 3 (Reserve)
Select
Confirm
Elec. meter 2 (Building)
Elec. meter 1 (PV)
10:34am,Mon
Heat-cool meter
- Set Heat-cool meter to Yes when this
generation meter is connected.
- It is to measure energy generation of heat
pump unit during heating, cooling and DHW
operation (one generation meter system)
or during heating and cooling only (two
generation meter system).
Tank meter
- Set Tank meter to Yes when this generation
meter is connected.
- It is to measure energy generation of heat
pump unit during DHW operation.
* Only available to select when Heat-cool
meter is set to Yes.
Only set Tank meter to Yes when the
connection is two generation meter system.
Elec. meter HP
- Set Elec. meter HP to Yes when this
electricity meter is connected.
- It is to measure energy consumption of heat
pump unit.
Elec. meter 1 (PV)
- Set Elec. meter 1 (PV) to Yes when this
electricity meter is connected.
- It is to measure energy generation of solar
system.
* This data will be displayed only on Cloud
system.
Elec. meter 2 (Building)
- Set Elec. meter 2 (Building) to Yes when this
electricity meter is connected.
- It is to measure energy consumption of the
building.
* This data will be displayed only on Cloud
system.