Operating Instructions

Air-to-Water Hydro Tank

Model No.

Indoor Unit

WH-ADC0509L3E5B

Outdoor Unit

WH-WDG05LE5

WH-WDG07LE5

WH-WDG09LE5

ENGLISH

Before operating the system, please read these 
operating instructions thoroughly and keep them 
for future reference.

WEB-ACXF55-36250-EN

Summary of Contents for WH-ADC0509L3E5B

Page 1: ...module Tank Model No Indoor Unit WH ADC0509L3E5B Outdoor Unit WH WDG05LE5 WH WDG07LE5 WH WDG09LE5 ENGLISH Before operating the system please read these operating instructions thoroughly and keep them...

Page 2: ...nstaller 5 Installer setup System setup 32 36 5 1 Optional PCB connectivity 5 2 Zone Sensor 5 3 Heater capacity 5 4 Anti freezing 5 5 DHW capacity 5 6 Base pan heater 5 7 Alternative outdoor sensor 5...

Page 3: ...ply Indoor Unit Structure of the unit may vary depending on the model Remote Controller Front Plate Tap Note Not recommended to open the Front Plate For authorised dealer specialist use only The illus...

Page 4: ...een given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall no...

Page 5: ...check RCCB ELCB operation regularly especially after installation inspection and maintenance RCCB ELCB malfunction may result in electric shock and or fire It is strongly recommended that Install Res...

Page 6: ...containers or Not immersed in water After a long period of use or use with any combustible equipment aerate the room regularly After a long period of use make sure the installation rack does not dete...

Page 7: ...thin a system is prohibited Operation maintenance repairing and refrigerant recovery should be carried out by trained and certified personnel in the use of flammable refrigerants and as recommended by...

Page 8: ...posal and c Able to understand and to apply in practice the requirements in the national legislation regulations and Standards and d Continuously undergo regular and further training to maintain this...

Page 9: ...se of flammable refrigerants Servicing shall be performed only as recommended by the manufacturer 2 2 Work Prior to beginning work on systems containing flammable refrigerants safety checks are necess...

Page 10: ...extinguisher adjacent to the charging area 2 5 No ignition sources No person carrying out work in relation to a refrigerating system shall use any sources of ignition in such a manner that it may lea...

Page 11: ...constructed of materials which are inherently resistant to being corroded or are properly protected against being so corroded 2 8 Checks to electrical devices Repair and maintenance to electrical comp...

Page 12: ...s NOTE The use of silicon sealant may inhibit the effectiveness of some types of leak detection equipment Intrinsically safe components do not have to be isolated prior to working on them 4 Repair to...

Page 13: ...requires brazing all of the refrigerant shall be recovered from the system The precautions in 8 must be followed to remove the refrigerant 8 Removal and evacuation When breaking into the refrigerant...

Page 14: ...discharging the refrigerant To avoid fire or explosion dissipate static electricity during transfer by grounding and bonding containers and equipment before charging discharging 10 Decommissioning Be...

Page 15: ...ants are removed safely When transferring refrigerant into cylinders ensure that only appropriate refrigerant recovery cylinders are employed Ensure that the correct number of cylinders for holding th...

Page 16: ...ry cylinder and the relevant Waste Transfer Note arranged Do not mix refrigerants in recovery units and especially not in cylinders If compressors or compressor oils are to be removed ensure that they...

Page 17: ...tective zone must not extend to adjacent buildings or public traffic areas boundaries of neighbors the public road neighbor s private roads subsidence area depressions pump shafts sewers intakes waste...

Page 18: ...with white icons 4 Main Menu button For function setup 5 ON OFF button Starts Stops operation 6 Operation indicator Illuminates during operation blinks during alarm When the backlight is off press any...

Page 19: ...k is installed The direction icons point to the currently active mode Room operation Tank operation Deice operation B Operation icons The status of operation is displayed Icon will not display under o...

Page 20: ...nth Day Hour Min 12 00 am 2022 1 Select with or how to display the time either 24h or am pm format for example 15 00 or 3 00 pm 2 Press to confirm the selection 3 Use and to select year month day hour...

Page 21: ...the setting according to the instructions displayed at the bottom of the screen The icons refer to each selection key Quick Menu Force DHW Powerful Quiet Force Heater Weekly Timer Force Defrost Error...

Page 22: ...f operation mode should change back to the previous memorized status Powerful Select this icon to operate the heating cooling system powerfully Press to confirm your selection The powerful operation s...

Page 23: ...2 The Quiet mode operates at level 3 Level 3 is the most quiet mode Select this to set a timer for the Quiet mode operation After 1 sec delay Select Yes Select Yes using buttons Select pattern 1 6 Sel...

Page 24: ...lection The Force Heater mode starts approximately 1 minute after is pressed Force Heater is turned off Force Heater is turned on Note Force Heater is disabled whenever operation is already on and Dis...

Page 25: ...Select the day s which you wish to edit using buttons If all 6 patterns are not preset this screen will be displayed 1 2 3 4 5 6 1 Select pattern 1 6 2 Set the hour and minutes of the Timer 3 Select O...

Page 26: ...lock the Remote Controller Press to confirm your selection When the mode has been accepted below screen will be displayed Select Yes The Main Screen will be locked If No is selected the screen will r...

Page 27: ...p 1 1 Weekly timer Once the weekly timer is set up User can edit from Quick Menu To set up to 6 patterns of operation on a daily basis Disabled if Heat Cool SW is select Yes or if Force Heater is on T...

Page 28: ...N or OFF ON Do not use the system during sterilization in order to prevent scalding with hot water or overheating of shower Ask an authorised dealer to determine the level of sterilization function fi...

Page 29: ...0 V and may differ from value measured by precise equipment 2 2 System information Shows all system information in each area Actual system information of 9 items Inlet Outlet Zone 1 Zone 2 Tank Pool C...

Page 30: ...RC No Confirm 10 34am Mon RC 1 3 2 Touch sound Turns the operation sound ON OFF ON 3 3 LCD contrast Sets the screen contrast 3 3 4 Backlight Sets the duration of screen backlight 1 min 3 5 Backlight i...

Page 31: ...SCH ITALIANO ESPA OL DANISH SWEDISH NORWEGIAN POLISH CZECH NEDERLANDS T RK E SUOMI MAGYAR SLOVEN INA HRVATSKI LIETUVI PORTUGU S EESTI LATVIE U ROM N SHQIP SLOVEN INA 3 9 Unlock password 4 digit passwo...

Page 32: ...or 2 zone system Zone After selecting 1 or 2 zone system proceed to the selection of room or swimming pool If the swimming pool is selected the temperature must be selected for T temperature between 0...

Page 33: ...n heater To select whether or not optional base pan heater is connected Type A The base pan heater activates only during deice operation Type B The base pan heater activates when outdoor ambient tempe...

Page 34: ...rate during low outdoor temperature Manual 5 17 Defrost signal To turn on defrost signal to stop fan coil during defrost operation If defrost signal set to yes bivalent function will not available to...

Page 35: ...tion meter is connected It is to measure energy generation of heat pump unit during heating cooling and DHW operation one generation meter system or during heating and cooling only two generation mete...

Page 36: ...n on Energy Monitor display data displayed on the remote controller is obtained through heat pump s internal calculation If Approx is NOT shown on Energy Monitor display data displayed on the remote c...

Page 37: ...ntal X axis 2 on vertical Y axis Heat ON Water temp Zone1 Confirm Select 55 C 75 20 20 15 35 C 5 C 15 C Temperature range X axis 20 C 15 C Y axis See below Temperature range for the Y axis input WH WD...

Page 38: ...ater ON OFF Water temperature for heater ON 4 C Setting of water temperature to turn on from water set temperature Heater ON OFF Water temperature for heater OFF 2 C Setting of water temperature to tu...

Page 39: ...m is selected temperature set point must input for Zone 2 Zone 1 and Zone 2 will not appear on the display if only 1 zone system T for cooling ON 5 C Set T for cooling ON This setting will not availab...

Page 40: ...3 functions at a time Floor operation time max 8 00 Maximum time for floor operation in hours and minutes Tank heat up time max 1 00 Maximum time for heating the tank in hours and minutes Tank re heat...

Page 41: ...w rate max duty and operation ON OFF of the pump Flow rate XX X L min Max Duty 0x40 0xFE Pump ON OFF Air Purge 7 2 Dry concrete To dry the concrete floor walls etc during construction Do not use this...

Page 42: ...ngle when one remote controller is connected Select Dual when two remote controllers are connected Second remote controller can be used for zone 2 room temperature control Single Selection of one or t...

Page 43: ...Do not obstruct the air inlet and outlet vents Failure to do so may result in low performance or system breakdown Remove any obstruction to assure the ventilation When it snows clean and remove snow...

Page 44: ...ses flammable gas may be mixed in so when venting keep ignition sources away and ventilate well User In order to ensure optimal performance of the units user may inspect and clear any obstruction on t...

Page 45: ...er time to heat up System does not heat up instantly System will take some time to heat up the water if it starts to operate at cold water temperature Backup heater is automatically turned ON when it...

Page 46: ...H76 RC 1 Indoor communication error RC 1 RC 2 communication error H90 Indoor Outdoor communication error H91 Tank heater OLP error H95 Voltage connection error H98 High pressure protection H99 Indoor...

Page 47: ...t phone device to prevent miss operation Do not use other remote control communication and operation device not specified by an authorised dealer or specialist Use under the agreement of Terms of Serv...

Page 48: ...is leaked together with an external ignition source there is a possibility of fire explosion This symbol shows that the Operation Instructions should be read carefully This symbol shows that a service...

Page 49: ...untry Hotline Phone Number Country Hotline Phone Number Austria 0800 700666 Hungary 36 1 382 60 60 Baltic 46 8 680 26 50 Netherlands 31 0 736402538 Bulgaria 359 2 971 29 69 Norway 47 210 339 99 Croati...

Reviews: