![Panasonic VL-V901 Installation And Operating Instructions Manual Download Page 17](http://html1.mh-extra.com/html/panasonic/vl-v901/vl-v901_installation-and-operating-instructions-manual_3989310017.webp)
3.3 Specifications
Lobby Station (VL-V900/VL-V901)
Power source
Power supply unit (VL-PS240: 220 – 240 V AC, 0.2 A, 50 / 60 Hz)
24 V DC, 0.6 A
Power consumption
Standby: Approx. 1.9 W
Operating: Approx. 4.5 W
Dimensions (mm)
(height
´
width
´
depth)
Approx. 373
´
179
´
2.5 (excluding sections embedded into the wall)
Mass (weight)
Approx. 2.0 kg
Operating environment
Ambient temperature for lobby station: approx. -10 °C to +55 °C
Ambient temperature for power supply unit: approx. 0 °C to +50 °C
Relative humidity: up to 90% (non-condensing)
(outdoor installation available; power supply unit is for indoor use only)
Display
Approx. 10.92 cm (4.3 inches) monochrome display (white backlit LCD)
Display the date, room number inputted by visitors, how to use, name of residents,
and custom item
Installation method
Flush mount (flush mounting box supplied)
External material
Stainless steel (partially ABS and PC)
Talking method
Hands-free
Heat sensor
Pyroelectric sensor installed (detecting human body, part of the stations become
luminous)
Image sensor
6.35 mm (1/4 inch) CMOS sensor (approx. 1M pixels)
Viewing angle
Super wide view (H: approx. 170° / V: approx. 115°
)
Minimum illuminance
1 lx
Lighting method
White coloured LED lights
Waterproof property
IP55
Vandal proof property
Compliant with IK07
Display languages
English
*1 VL-V900
*2 VL-V901
17