background image

4-2. Connecting to analogue security cameras & Monitor Uses

4

Integration

1 camera can be connected to each lobby station.

1 Monitor can be connected to Control Box

Lobby

48

Gym/Pool

CCTV)

Security(Monitor)

Gate

CCTV)

Summary of Contents for VL-V900

Page 1: ...2016 Video Intercom INSTALLATION GUIDE...

Page 2: ...mparison chart 2 12 Apartment mode or Housing mode INDEX 3 Wiring 3 1 Basic System Example 3 2 Basic System Configuration 3 3 Large System Example 3 4 Large System Configuration 3 5 Cable Information...

Page 3: ...evice 6 Operation 6 1 Lobby station operations 6 2 Facility staff operations P54 P55 P60 P61 P62 P63 P64 P65 P66 P67 P68 P69 P70 P71 P74 P75 INDEX 10 Appendix 10 1 VL V900 Series Specifications 10 2 I...

Page 4: ...Why Choose a Panasonic Video Intercom System 1...

Page 5: ...This wide angle camera allows broad lobby areas to be securely monitored Linked Functionality with Security Cameras and SD Recording Functions In addition to providing linked functionality with secur...

Page 6: ...Role Features Installation 1 2...

Page 7: ...11 MW251 MV26 Role Features Installation Lift Controller VL V702 2 Electric Locks PBX Terminals Security Camera TV Monitor 1 unit 1 unit 4 units Up to 1 per lobby station up to 3 lobby stations 1 unit...

Page 8: ...900 Lift Controller VL V702 Main Monitor VL MVN511 MW251 MV26 Distribution Box VL V701 Monitor Lobby Station or Security Camera Open E Lock Control Lift Call Talk Save Images Logs Security Camera E LO...

Page 9: ...de angle camera Horizontally 170 vertically 115 Industry average Approx 90 Almost the full width is visible Approx 170 Industry average Approx 70 Approx 115 The face can be seen regardless of height a...

Page 10: ...efault camera view Wide or 9 Zoom position by using Setup Tool Wide View Features View Angles Wide Zoom and Pan Tilt Zoom View Select 9 position Change camera view Wide Zoom and Pan Tilt Change the vi...

Page 11: ...of the flush mount box and then pass all necessary cables and wires DC cable wires for control box access controller electric lock etc through the knockout holes Step 2 Step 3 Mount the box in the wa...

Page 12: ...C cable from power supply unit 3 Hooks for securing the DC cable 4 Coaxial cable from external camera 5 Wires from control box 6 Wires from access controller 7 Wires from electric lock 8 Wire release...

Page 13: ...ation Category Meaning POWER GREEN ACCESS RED Idle Lit Off Call or monitoring in progress Lit Lit Accessing SD card Lit Flashing quickly System setup PC programming in progress Lit Lit PC connection c...

Page 14: ...r Duplicate distribution box number found Off Flashing slowly Duplicate lift controller number found Off Flashing slowly Normal operation 1 Power indicator POWER 2 Access indicator ACCESS 3 Connection...

Page 15: ...11 MW251 20 DB1 DB2 MV26 Termination ON Repeater OFF Control Box Lobby Station Category Meaning POWER GREEN ACCESS RED Normal operation Idle Lit Off Call or monitoring in progress Lit Lit Error DIP sw...

Page 16: ...Power Supply Unit Role Features Installation Category Meaning POWER GREEN ACCESS RED Normal operation Idle Lit Off Call or monitoring in progress Lit Lit Error DIP switch 8is in the on position Off F...

Page 17: ...n Controlling the destination floor of visitors by linking with the lift and lift control box Role Features Installation Residents 302 push the button And answer The Lift controller accepts only 3rd F...

Page 18: ...box VL V701 4 3F Accept Can program the Relay operation 1 20 Accept In order for the function to work settings need to be confirmed in advance with the lift manufacturer Role of the VL V702 Supported...

Page 19: ...ut for lift controller 6 Connection terminals for lifts 7 Reset button Used when restarting the lift controller 8 Function button For internal use only 9 Power switch 10 Cable release button for DC po...

Page 20: ...ion terminals for DC power supply 7 Reset button Used when restarting the extension box 8 Function button For internal use only Category Meaning POWER GREEN ACCESS RED Idle Lit Off Call in progress Li...

Page 21: ...ng sound notification Sales Point Configuration of connected devices Role Features Installation Relay box 2 2 Relay box is included with VL SVN511 but not included with VL MVN511 1 Door Bell is connec...

Page 22: ...Main Monitor VL MVN511 Rea Side Role Features Installation 2 Commercially Sensor or Button Support Emergency call Commercially Sensor or Button Support Door Bell D3 D4 Door Station D1 D2 Distribution...

Page 23: ...max 50 sessions Auto picture recording 2 Picture recording function Can view visitors in color even at night 3 LED Lighting Door station Sales Point Configuration of connected devices E Lock1 Lobby St...

Page 24: ...Picture recording function Simple UI with big talk off button 3 Easy to use big button Sales Point E Lock1 Lobby Station Main Monitor Door Bell Role Features Installation AC DC 24V Attached Power Sup...

Page 25: ...8 shots per visitor Yes Up to 30 visitors 1 shot per visitor Door Station Yes Option Yes Option Door Bell Yes Option 3rd party Yes Option 3rd party E Lock Release Public Individual Yes Option Yes Yes...

Page 26: ...ment mode or Housing mode Role Features Installation 2 Default is the House mode But no need to change the mode When connect to the large apartment system and run the Connection Check by Setup tool it...

Page 27: ...Wiring 3...

Page 28: ...AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC Room System Main Monitor Lobby Station Control Box Distribution Box Main Monitor 1 unit 1 unit 1 units 20 units Lobby Station VL V900 Entran...

Page 29: ...stem Configuration Rear Side 3 Wiring Basic system example Power Supply Unit Lobby Station 1 Control Box 1 Distribution Box 1 Room unit up to 20 Main Monitor Door Station 1 19 Power Supply Unit Power...

Page 30: ...VL V900 Lobby Station Control Box Distribution Box Main Monitor 3 units 1 unit 28 units 560 units Control Box VL V700 4 branches x 7 series connections x 20 dividers 560 units 1 1 1 2 1 7 2 1 2 2 2 7...

Page 31: ...ion VL V900 Lobby Station Extension Box Control Box Distribution Box Main Monitor 18 units 3 units 1 unit 28 units 560 units Control Box VL V700 4 branches x 7 series connections x 20 dividers 560 uni...

Page 32: ...t Lobby Station 2 Lobby Station 3 Power Supply Unit Power Supply Unit 6 3 4 Large System Configuration Rear Side 3 Wiring Distribution Box 2 1 1 20 Power Supply Unit Power Supply Unit Power Supply Uni...

Page 33: ...Diameter of Wire 0 65 mm 22 AWG 1 20 mm 17 AWG Supply 24 V DC from Power Supply Unit Diameter of Power Cable 0 65 mm 22 AWG Max length 10 m 2 00 mm 12 AWG Max length 20 m Uses 2 wire cable Uses 2 wire...

Page 34: ...mm 17 AWG approx 200 m Power supply unit Lobby station Control box Distribution box Lift controller 0 65 mm 22 AWG approx 10 m 2 mm 12 AWG approx 20 m Power supply unit AC power source 1 2 mm 17 AWG N...

Page 35: ...L V701 Lobby Station VL V900 V701 Repeater Mode 1 Distribution Box VL V701 Lobby Station VL V900 Control Box VL V700 By connecting a VL V701 repeater between the VL V700 and VL V701 07 the range can b...

Page 36: ...by Station 10 If you use CAT6 Cable instead of 2wire cable Control Box VL V700 V701 Repeater Mode The Farthest Monitor The Farthest Monitor The Farthest V701 34 Case3 same as 1 pair x 2 110m 2 pair x...

Page 37: ...switch DIP switches Repeaterswitch Termination switch DIP switch setting is Ignored when repeater switch is set to the ON position OFF ON ON DIP switches Repeater switch Termination switch 1 2 3 4 5...

Page 38: ...en Only Relay 4 3F will be active 1 G 2 1F 3 2F 19 18F 20 19F Lift Control System Panasonic Lift Controller VL V702 Lift Control box VL V700 Distribution box VL V701 4 3F Accept Can program the Relay...

Page 39: ...optional input ports to integrate with other system ex Video Intercom Access control These input ports may be installed at the top or bottom of lift system In order for the function to work settings...

Page 40: ...loor per lift Up to 20 floor per lift controller 38 Port ofLift Controller 1 2 3 4 5 6 7 8 9 10 Floor 11 12 13 14 15 16 17 18 19 20 19 F 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 10 F 0 0 0 0 0 0 0 0 0...

Page 41: ...r settings Up to 6 lifts Up to 6 Lifts By connecting one branch per two lift you can integrate up to 6 lifts 3 branch x 2 lift controller x 2 lift systems It can support up to 40 floor per lift 39 Lif...

Page 42: ...or Door Station Power Supply Unit Power Supply Unit Power Supply Unit Power Supply Unit Power Supply Unit Lift Controller 2 1 Lift Controller 2 5 Power Supply Unit Power Supply Unit Lift Controller 3...

Page 43: ...IP switch Floors 0 19 0 is the ground floor 99F 89F 80F 19 F 9 F 0 F 59 F 49 F 40 F 79 F 69 F 60 F 39 F 29 F 20 F 99F 89F 80F 19 F 9 F 0 F 59 F 49 F 40 F 79 F 69 F 60 F 39 F 29 F 20 F 3 4 5 DIP switch...

Page 44: ...Lift Controller Floor bit 7 6 5 4 3 2 1 99 F 100 1 1 0 0 1 0 0 98 F 99 1 1 0 0 0 1 1 97 F 98 1 1 0 0 0 1 0 7 F 8 0 0 0 1 0 0 0 6 F 7 0 0 0 0 1 1 1 5 F 6 0 0 0 0 1 1 0 4 F 5 0 0 0 0 1 0 1 3 F 4 0 0 0 0...

Page 45: ...Integration 4...

Page 46: ...Security Office Terminal 3 Named Parking Extension No 106 Extension No 107 Lobby Station VL V900 Entran ce Main Monitor VL MVN511 MW251 MV26 Room Control Box VL V700 Distribution Box VL V701 Control...

Page 47: ...d Parking How to call from Room to Terminal 1 Push the TALK button 2 Select Terminal name 3 Press OK 3 System 4 Integration 4 1 How to call PBX between Room and Terminal 44 Telephone cable RJ 11 How t...

Page 48: ...L MVN511 MW251 MV26 Room Lobby Station VL V900 Entrance Terminal 1 Named Reception System Main Monitor VL MVN511 MW251 MV26 Room Main Monitor VL MVN511 MW251 MV26 Room Reception Reception mode Switchi...

Page 49: ...rt Emergency call from Room No automatically start talking between room and Terminal Emergency Notice mode Guidance start and continue Emergency call from Room No Emergency call from Room No Emergency...

Page 50: ...System Camera 2 Named PARKING Lobby Station VL V900 Analogue Security Camera NTSC PAL Camera 3 Named GYM Lobby Station VL V900 Analogue Security Camera NTSC PAL Guard Security Display on the monitor i...

Page 51: ...onnecting to analogue security cameras Monitor Uses 4 Integration 1 camera can be connected to each lobby station 1 Monitor can be connected to Control Box Lobby 48 Gym Pool CCTV Security Monitor Gate...

Page 52: ...Monitor 102 Lobby2 Monitoring Lobby1 Main Monitor 103 General Call Main Monitor 101 Emergency Terminal Emergency call Terminal 1 Main Monitor 103 General Call Main Monitor 102 Lobby2 Monitoring 2 All...

Page 53: ...Entrance 4 4 Access Control E Lock 50 4 Integration Main Monitor VL MVN511 MW251 MV26 Room Control Box VL V700 Distribution Box VL V701 System Lobby Station VL V900 Access control Electrical Lock...

Page 54: ...y Station Access Control Card Reader Outside 2 N P K OUT K IN 2 N P E Lock Lobby Station K OUT K IN DOOR EXIT OR Poewe r supply 12 V DC K OUT K IN N P N P N P POWER SUPPLY UNIT VL V900 Switch Inside S...

Page 55: ...UNLOCKED If integrate Access Control 1 Card Key Outside Card Reader Outside If integrate Access Control 2 Switch Inside 3 Input Pin cord Outside Lobby Station Outside Input a four digit pass code 4 Ro...

Page 56: ...2 2015 1 1 4 30 2015 1 1 4 30 T O SAVED 100_0001 LOBBY_01 RM_00102 RM_00102 2015 1 1 4 30 2015 1 1 4 30 TALK SAVED 100_0002 LOBBY_01 RM_00102 RM_00102 2015 1 1 4 30 2015 1 1 4 31 UNLOCK EV SAVED 100_0...

Page 57: ...Setup Tool 5...

Page 58: ...ut 40sec until they start flashing Power LED Access LED 6 When Power LED has turned off and the Access LED is lit the update is finished Turn off the power switch It takes about 20min in total Power L...

Page 59: ...he data to the system while on site The Panasonic Large Apartment System Setup Tool is also called setup tool in this document System requirements Operating system Microsoft Windows 7 Microsoft Window...

Page 60: ...2 No 303 No 304 No 401 No 402 No 403 No 404 Port5 Port1 Port4 Port8 Port6 Port7 Port2 Port3 Control Box VL V700 Distribution Box VL V701 Lobby Station VL V900 No 101 No 102 No 103 No 104 No 201 No 202...

Page 61: ...Box Connect the PC vis USB and upload the date to the Control Box and Lobby from setup tool Control Box VL V700 Lobby Station VL V900 3 Wiring all monitors based on the drawing and upload set the dat...

Page 62: ...Port Port Port Port Port Port Port Port Control Box VL V700 Distribution Box VL V701 Lobby Station VL V900 No 101 No 102 No 103 No 104 No 201 No 202 No 203 No 204 Port1 Port8 Port Port Port Port Port...

Page 63: ...t know where the each cable connect to Push 3 buttons and Power on Save Save the programing date in the internal memory No 301 Port Port Control Box VL V700 Distribution Box VL V701 Set Save in the i...

Page 64: ...he existing system 2 On the PC setup tool select the back up date folder and then select the existing files No 301 Control Box VL V700 Distribution Box VL V701 3 Connect the PC and Control Box vis USB...

Page 65: ...the current data from the system s devices 3 Load and edit the data Allows you to load the data saved in the configuration files into the setup tool for uploading or editing 4 Upload the data to devic...

Page 66: ...tup Tool 5 Step 1 Select folder To create NEW configuration file Step 2 Click These files are generated to the selected folder by Step1 Step 3 Step 4 Click The paths of each configuration file are dis...

Page 67: ...o the configuration file 2 Change the values in the appropriate columns 4 Click Tips Editing configuration files directly Use a third party text editor or spreadsheet program to open the configuration...

Page 68: ...devices Setup Tool 5 To download from devices Step 1 Select folder Step 2 Note Before download from devices connect the computer to the control box with a USB cable Turn on the checkboxes for the desi...

Page 69: ...nding control box port distribution box number and distribution box port 1 99999 Floor No Determines the floor number setting of the corresponding room number 0 99 0 is the ground floor 0 Lift access...

Page 70: ...priority 1 900 s or 0 to disable 300 300 SEC Visitor Call Mode Determines if visitors can call rooms directly room mode or if their calls are directed to a reception terminal reception mode 0 ROOM MO...

Page 71: ...Room settings Setup Tool 5 Parameter Description Default Room No Determines the room number 0 99999 Resident Name Determines the resident name for the corresponding room number 20 characters max uppe...

Page 72: ...d 0 CLOSE 1 OPEN 0 CLOSE Camera Connection Tells the system whether a camera is connected or not 0 NO 1 YES 0 NO Camera Name Determines the camera name 1 CAMERA 2 RECEPTION 3 GATE 4 CONTROL ROOM 5 RES...

Page 73: ...bby station exits programming mode and the standby screen is displayed Entering numbers and characters You can use the keypad to enter numbers and characters Press a key repeatedly to scroll through t...

Page 74: ...ANT 13 PARKING 06 HALL 14 TERRACE 07 POOL 15 LIFT LOBBY 08 SECURITY OFFICE Feature number Description Emergency terminal 1 Terminal 1 Terminal 2 Terminal 3 Terminal 4 5 Enter a feature number to speci...

Page 75: ...s settings While performing the next steps you can cancel without saving your settings by pressing OFF 5 Enter the room number a Use the navigator key to select the desired number b Use the navigator...

Page 76: ...e for visitors to each lobby b Press to select the next lobby station c Press OK when finished 8 Confirm the displayed settings Press EDIT to go back and enter the desired settings again 9 Press SET t...

Page 77: ...ice Setup Tool 5 You can restart the control box distribution box or lift controller by pressing its reset button Reset button Reset button Reset button Reset button VL V900 VL V700 VL V701 VL V702 73...

Page 78: ...Operation 6...

Page 79: ...repeatedly to scroll through the letters assigned to that key Note the hints displayed at the bottom of the screen 3 Press or to search for the desired name 4 Press to call Searching through all name...

Page 80: ...n the entrance door based on the conversation he she had with the visitor When the visitor call mode setting is set to reception mode calls from lobby visitors are directed to a reception terminal eve...

Page 81: ...Replace 7...

Page 82: ...tribution Box VL V701 Control Box VL V700 RISER POWER POWER POWER POWER POWER DC Power IP LAN L2 Switch Hub AC L2 Switch Hub L2 Switch Hub Room Monitor Lobby Station Control Box Distribution Box New C...

Page 83: ...le Cat 6 Control Box Distribution Box New Cable Cat 6 Distribution Box Room Monitor Exiting Cable PVC cable less than 30m Replace from Intercom system PVC mesh cable Distribution Box VL V701 Control B...

Page 84: ...than 30m from Raiser Raiser Replace exiting PVC cable to CAT6 cable from Control Box to each distribution box Exiting Fermax Lobby Station have camera But room monitor do not support Video Back board...

Page 85: ...ol Box and Distribution Box Cat5E Cable to Each Room Monitor Room Raiser Power Cable Remove the Existing Room Monitor Connect the Cat5e and Power Cable Existing Power Supply Power Supply PS240 Put the...

Page 86: ...Distribution Box VL V701 Control Box VL V700 Cat6 Cable 1 2mm 0 65mm RISER IP LAN PoE SW Hub L2 Switch Hub Room Monitor Lobby Station PoE SW Hub Cat5e Cable Lobby Station Control Box Existing Cable Ca...

Page 87: ...wire Distribution Box VL V701 Distribution Box VL V701 Control Box VL V700 RISER Lobby Station Control Box Existing Cable Cat3 New Cable Control Box Distribution Box New Cable Cat 6 1 2mm 0 65mm Distr...

Page 88: ...Estimate 8...

Page 89: ...How to make an estimate of the system 8 Estimate 82 Huge Multi Building Villa complex High rise...

Page 90: ...oxes are needed 11 20 Rooms Floor Install one distribution box per each floor 301 302 303 316 317 320 201 202 203 216 217 220 3F 2F 1F 101 102 103 116 117 120 Distribution box Distribution box Distrib...

Page 91: ...10 Rooms Floor Install one distribution box per two floors 301 302 303 310 201 202 203 210 101 102 103 110 3F 2F 1F Distribution box Distribution box How many distribution boxes are needed 8 Estimate...

Page 92: ...Case study 8 Rooms Floor Indonesian project 1 2 3 4 5 6 7 8 Distribution box Distribution box Control box How many distribution boxes are needed 1F 2F 4F 3F 5F 6F 8 Estimate 85...

Page 93: ...How many distribution boxes are needed 6 Rooms Floor Install one distribution box per three floors 301 302 306 201 202 206 101 102 106 3F 2F 1F Distribution box 8 Estimate 86...

Page 94: ...Case study 6 Rooms Floor Myanmar Project 1 2 3 4 5 6 Distribution box Control box 1F 2F 3F 4F 8 Estimate How many distribution boxes are needed 87...

Page 95: ...Main Monitor Power Supply 8 Estimate AC DC 24V Attached Power Supply Unit AC DC 24V VL MVN511 VL MV26 AC power directly VL MW251 AC 88...

Page 96: ...2F AC 220V 8 Estimate Where is Power supply unit installed AC 220V Supplied AC Power from each room Power supply unit of MV511 MV26 is installed at room MW251 is directly connected to AC 220V of room...

Page 97: ...e is Power supply installed 301 302 306 201 202 206 3F 2F AC 220V AC 220V 8 Estimate Install Power supply unis at Riser and DC output is wired to each monitor DC 24V DC 24V DC 24V DC 24V DC 24V DC 24V...

Page 98: ...2 306 201 202 206 3F 2F AC 220V AC 220V 8 Estimate Cat5e Cat6 Cable Cat3 0 65mm 4wire Install Power supply unis at Riser and DC output is wired with signal cable Up to 70m Where is Power supply instal...

Page 99: ...0units 20units 20units Tower1 20units 20units 20units Tower2 20units 20units 20units Tower3 20units 20units 20units Tower4 Distribution box Repeater Repeater 100m 0 65 200m 1 2 100m 0 65 200m 1 2 Dist...

Page 100: ...How to support multi building Case study 3 tower 1 entrance Malaysia project Distribution box Repeater Distribution box Repeater Distribution box Control box 8 Estimate 93...

Page 101: ...How to support multi building 8 tower 2 entrance Lobby for Tower1 4 Lobby for Tower5 8 Lobby for Tower1 4 Lobby for Tower5 8 8 Estimate 94...

Page 102: ...How to support more than 4 Lobby Station project 8 Estimate We will Launch Extension box VL V703 at the end of July 95...

Page 103: ...gh rise building with 8 Lobby Stations Repeater Extension Box 20F 15F 14F P P P 13F 7F 6F 5F 4F 1F GF Control box Distribution box 8 Estimate How to support more than 4 Lobby Station project Repeater...

Page 104: ...How to support the villa complex 8 Estimate 97...

Page 105: ...ntrol box Distribution box Repeater Distribution box Distribution box Distribution box Repeater Distribution box Distribution box Outdoor cabinet 8 Estimate Piping under the ground Case study 108 hous...

Page 106: ...ons with CCTV or terminals Qty of Reception security room How many terminals which is integrated with PBX Qty of Lift How many Lift controllers Public space for monitoring How many Analog CCTV which i...

Page 107: ...Signal cable Power cable length of each cable Existing type of cable Check the possibility of replace by using existing cable Signal cable Power cable Type of cable CAT5e CAT3 telephone cable PVC cab...

Page 108: ...FAQ 9...

Page 109: ...Appendix 10...

Page 110: ...Hands free Viewing angle Horizontally Approx 170 Vertically Approx 115 Installation method Flush mount flush mounting box supplied Image sensor 1 0 M pixel CMOS Minimum illuminance 1 lx within approx...

Page 111: ...nstallation method Wall mount or attach to DIN rail External material ABS flame retardant ABS resin Log Save the text logs and visitors images in the SD card sold separately Text logs More than 90 000...

Page 112: ...DIN rail External material ABS flame retardant ABS resin Log Save the text logs and visitors images in the SD card sold separately Text logs More than 90 000 items Images Up to 90 000 images Supported...

Page 113: ...ng protruding sections 108 5 x 210 x 52 5 mm Weight 400 g Operating environment Ambient temperature Approx 10 C to 50 C Relative humidity non condensing up to 90 indoor use only Installation method Wa...

Page 114: ...Approx 0 4 W During operation Approx 4 4 W Dimensions H x W x D Excluding protruding sections 210 x 108 5 x 52 5 mm Weight 400 g Operating environment Ambient temperature Approx 0 C to 50 C Relative h...

Page 115: ...by Approx 1 5W During operation 1 3W Dimensions H x W x D Excluding protruding sections 210 x 108 5 x 52 5 mm Weight 400 g Operating environment Ambient temperature Approx 10 C to 50 C Relative humidi...

Page 116: ...perating environment Ambient temperature Approx 0 C to 40 C Relative humidity non condensing up to 90 Ambient temperature Approx 0 C to 40 C Relative humidity non condensing up to 90 Ambient temperatu...

Page 117: ...trol Box VL V701 Distribution Box VL V702 Lift Controller 1 Wire release button 2 Connection terminal 3 Wires to from other devices 4 Cable release button for DC power supply cable 5 DC cable from pow...

Page 118: ...cable covers 2 Connect the AC DC cable to the AC IN terminal DC OUT terminal on the top and bottom of the power supply unit and then securely fasten the screws 3 AC cable binder hole DC cable Screws 3...

Page 119: ...vice must be installed inside an electrical panel or cabinet A readily accessible disconnect device shall be incorporated external to the equipment External disconnect device must be certified and hav...

Page 120: ...om Unit up to 560 01 01 07 01 07 Distribution Box 06 04 07 05 Repeater Mode Repeater Mode 01 05 01 05 01 05 Lobby Station up to 3 Distribution Box up to 28 up to 5 per lift TV Monitor 1 NTSC PC progra...

Page 121: ......

Page 122: ...e either registered trademarks or trademarks of Microsoft Corporation in the United States and or other countries All other trademarks identified herein are the property of their respective owners The...

Reviews: