Lobby Station      [VL-V900]  up to 3 units (up to 18*)

Extension Box     [VL-V703]  up to 3 units

Control Box         [VL-V700]  up to 1 unit

Distribution Box  [VL-V701]  up to 28 units

Main Monitor                          up to 560 units
Lift Controller      [VL-V702]  up to 15 units (up to 3 Lifts)

DIP

switches

Repeater

switch

Termination

switch

Main Monitor

(up to 20) 

#1

#20

Power

Supply

Unit

Power

Supply

Unit

Distribution Box #1-2

IN

OUT

Repeater

1 2 3 4 5 6 7 8

ON

OFF

 (on)

 (on)

Distribution box

DIP switches

Repeater switch Termination switch

1 2 3 4 5 6 7 8

ON

OFF

 (off)

1 2 3 4 5 6 7 8

ON

OFF

 (off)

ON

OFF

 (off)

ON

OFF

 (off)

1 2 3 4 5 6 7 8

ON

OFF

 (off)

1 2 3 4 5 6 7 8

ON

OFF

 (off)

1 2 3 4 5 6 7 8

ON

OFF

 (off)

 (on)

 (off)

 (off)

 (off)

 (off)

 (off)

 (off)

#1-4

#1-7

#1-6

#1-5

#1-3

#1-2

#1-1

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

NP: Non-polarised

COAX

DC IN

V700

K-OUT

K-IN

L2

L1

C2

C1

S2

S1

ON

OFF

USB

DC IN

RJ11

Branch #1

Lobby Station (up to 18)

Extension Box (3)

Control Box (1)

NP

NP

NP

PC

NP

12 V DC

NP

Access

controller

(input)

Electric

lock

(output)

TV Monitor

PBX

(6 lobby station for each

extension box)

DC IN

NP

DIP SW 1 : ON

1

Lift Controller

(up to 15 for Relay)
Lift Controller

(up to 3 for Binary)

Distribution Box #1-1

*Up to 18 Lobby Ststion can be installed by adding Extension Boxes.

Power Supply Unit

Power

Supply

Power

Supply Unit

NP

NP

NP

NP

NP

NP

NP

NP

NP

NP

NP

NP

NP

Distribution

Box #1-4

Distribution

Box #1-7

Distribution

Box #1-5

Distribution

Box #1-3

Distribution

Box #1-6

Branch #2

Branch #3

Branch #4

Lobby Station #6

Lobby Station #5

Lobby Station #4

Lobby Station #3

Lobby Station #2

Repeater

Power

Supply Unit

Wiring Distance

*Use PE(polyethylene)-insulated cables.

Wiring run

Wire diameter

0.65 mm (22 AWG) 1.2 mm (17 AWG)

100 m

200 m

100 m
100 m
100 m
100 m

200 m
200 m
200 m
200 m

Lobby Station  - Control Box
Control Box - Distribution Box (Standard Mode)
Distribution Box (Standard Mode) - Main Monitor
Control Box - Distribution Box (Repeater Mode)
Distribution Box (Repeater Mode) - Distribution Box (Standard Mode)

Key Features

VL-V900

Lobby Station

VL-V700

Control Box

VL-V701

Distribution Box / 

Repeater Box

VL-V702

Lift Controller 

VL-V703

Extension Box 

• Large-capacity, expandable:

The system supports up to 560 room units (main monitors) and 3 lobby stations.

Optional devices such as cameras, access controllers (door openers, key switches, card scanners, etc.), electric locks, and a TV monitor can be connected.

The system can be integrated with a Panasonic PBX system used by facility staff.

Extension boxes can be used to increase the number of lobby stations that can be used in the system. Up to 3 extension boxes can be connected to the control 

box, and up to 6 lobby stations can be connected to each extension box. In all, the system supports up to 18 lobby stations.

• Easy to install, configure and maintain:

The system mainly needs only 2 wire cables (1 pair of cables), and minimal equipment.

System settings can be configured in advance using a computer, and uploaded on-site via USB connection.

System settings can be configured on-site using a lobby station, main monitor, and PBX extension telephone.

System events can be logged on an optional SD card (up to 90,000 images captured by a lobby station camera with text logs).

• Convenient features for residents, visitors, and facility staff:

The system can be used in the “room mode” (visitors can call rooms directly) or “reception mode” (visitors calls are routed through a receptionist).

Visitors can use a lobby station to call residents or facility staff.

Residents can use their room monitors to monitor lobby stations and optional cameras, and can allow visitors to enter the lobby and lift.

Residents can use their room monitors to make emergency calls to facility staff. (Not available with the VL-MW251) 

Facility staff can make and receive calls to and from residents and visitors.

Wiring Diagram

Accessory Information

Optional Accessories

Video Intercom System

for Apartment complexes

For the Lobby Station

Flush mount box x1, Screw for Flush mount box (4 mm x 25 mm) x4, Hex wrench x1, Power supply 

unit x1 (AC cable is not included.)

Screw for power supply unit (4 mm x 40 mm) x2, Cable binder x2

For the Control Box, Distribution Box, Lift Controller, Extension Box 

Screw for mounting the box (3.8 mm x 20 mm) x2, Power supply unit x1 (AC cable is not included.)

Screw for power supply unit (4 mm x 40 mm) x2, Cable binder x3

Main Monitor

(Smartphone Connect 

Model)

VL-MVN511

Main Monitor

(2.4GHz Wireless 

Monitor Connect Model)

VL-MW251

Main Monitor

(DECT Wireless Monitor & 

Wired Monitor Connect Model)

VL-MWD272

Setup tool, USB driver, manual and

the latest firmware

Download information is available at the 

following web site.

http://panasonic.net /pcc/support /intercom/v900

VL-V900

 

and

 

VL-V700

 

series

Main Monitor

(Standard Model)

VL-MV26

3.5-inch

5-inch

wide

7-inch

wide

5-inch

wide

Reviews: