Panasonic VL-MV74 Installation Manual Download Page 2

2

For your safety

To prevent severe injury or loss of life or 
property, and to ensure proper and safe 
operation of your product, read this 
section carefully before using the 
product.

Preventing fire, electric shock and 
short circuits

R

Leave installation work to the 
dealer. Installation work requires 
technique and experiences. Failure 
to observe this may cause fire, 
electric shock, injury, or damage to 
the product. Consult the dealer.

R

Electrical connection work should 
be performed by certified personnel 
only. Certification is required for 
performing electrical connection 
work. Consult your dealer.

R

Do not attempt to disassemble or 
modify this product. Contact an 
authorised service centre for repairs.

R

Never install wiring during a lightning 
storm.

R

Do not connect non-specified devices.

R

Do not connect a power cable to a 
terminal that is not specified in this 
guide.

R

When opening holes in walls for 
installation or wiring, or when securing 
the power cable, make sure you do not 
damage existing wiring and ductwork.

R

Do not make any wiring connections 
when the power supply is turned on.

R

Do not install the main monitor/
extension monitor in the following 
places:

– Places where the main monitor/

extension monitor may be splashed 
with water or chemicals.

– Places where there is a high 

concentration of dust, or high 
humidity.

R

Do not place objects on the power 
cables.
Install the product where no one can 
step or trip on the power cables.

R

Do not allow the power cables to be 
excessively pulled, bent or placed 
under heavy objects.

R

When existing wires are used, it is 
possible that they contain AC voltage.
Contact an authorised service centre.

Preventing electric shock

R

If the wiring is underground, do not 
make any connections underground.

R

If the wiring is underground, use a 
protection tube.

R

If the wiring is outdoors, use a 
protection tube or a surge protector.

Preventing injury

R

I

nstall the product securely adhering to 

the instructions in this guide to prevent 
it from falling off the wall. Avoid 
installing onto low-strength walls, such 
as gypsum board, ALC (autoclaved 
lightweight concrete), concrete block, 
or veneer (less than 18

mm

 thick) 

walls.

WARNING

CAUTION

prj_6905-en_gb.book  Page 2  Friday, March 8, 2019  2:29 PM

Summary of Contents for VL-MV74

Page 1: ...rphone and the main monitor extension monitor R Please read this guide carefully and install the product safely and correctly by following the instructions Carefully read the information found in the section titled For your safety in particular R Only use attachments accessories specified by the manufacturer R The installation shall be carried out in accordance with all applicable installation rul...

Page 2: ...ductwork RDo not make any wiring connections when the power supply is turned on RDo not install the main monitor extension monitor in the following places Places where the main monitor extension monitor may be splashed with water or chemicals Places where there is a high concentration of dust or high humidity RDo not place objects on the power cables Install the product where no one can step or tr...

Page 3: ...om the actual product 1 Used when using a separately sold flush mount box for installation For the doorphone Mounting base 1 Screw 2 3 8 mm 20 mm Screw 4 4 mm 12 mm Screw 4 4 mm 25 mm 1 For the main monitor extension monitor Screw 2 4 mm 16 mm Mounting bracket 1 Locally procured Wires for doorphone and other connections Prepare wires of the appropriate specification a Wire type and length prj_6905...

Page 4: ...ppropriate water protection treatment is performed R Make sure the rear of the doorphone is not subject to water R Depending on the installation location condensation may form on the doorphone s lens cover This may cause images to become obscured Condensation will dissipate as the temperature rises For the main monitor extension monitor R Leave at least 20 cm of space above below and to the left a...

Page 5: ... connect doorbells to the IN3 IN4 terminals A doorbell and doorphone 2 cannot be used together When a VL V901 and VL V700 series Video Intercom System for Apartment Complexes is used emergency terminals can be used Make sure to connect emergency terminals to the IN1 IN2 terminals Ml 1 Ml 2 5 6 Ml 1 Ml 2 5 6 Ml 1 Ml 2 5 6 EXTENSION MONITOR 1 EXTENSION MONITOR 2 EXTENSION MONITOR 3 DOORPHONE 1 DOORP...

Page 6: ...tion terminal S1 S2 S3 S4 N O dry closure contact 30 V AC 1 A 24 V DC 1 A or lower R Connection device for option input A contact terminal IN1 IN2 IN3 IN4 Input method No voltage contact Open circuit voltage between terminals DC 7 V or less Detection definite time 0 1 second or more Short circuit between terminals 5 mA or less Resistance value make 500 Ω or less break 15 KΩ or more Wiring run Wire...

Page 7: ...or Operating Instructions of the Video Intercom System Note R Connection for VL V901 and VL V700 series Video Intercom System for Apartment Complexes Connect terminal D1 D2 on the main monitor with terminal D1 D2 on the VL V701 Distribution Box R Connection for VL VM series VL VM701 Video Intercom System Lobby station Distributor Connect either terminal D1 D2 or D3 D4 on the main monitor with the ...

Page 8: ... L Approx 85 M Approx 500 1 If the camera points 15 upwards the left or right angle is less than 5 Note R The measurements and angles are for reference purposes and may vary depending on the environment A C D E G H I J K A view when looking from above B F The camera angle can be adjusted using the camera angle control lever on the rear of the doorphone step 3 Installing the doorphone so that the i...

Page 9: ... vertical flat wall A Screws accessory 2 C Wire locally procured D 83 5 mm 1 To prevent dew condensation fill a hole for wiring as much as possible 2 Use a slotted screwdriver A to push into the holes on the bottom side of the front panel and remove the front panel B of the doorphone 3 Adjust the camera angle using the camera angle control lever A Camera angle control lever B Left maximum 15 C Rig...

Page 10: ...l connectors non polar then tighten the screws A 5 Attach the doorphone to the mounting base A Screws accessory 4 6 Attach the front panel in the order of A B A Recommended torque 0 5 N m 5 1 kgf cm Maximum torque 0 7 N m 7 1 kgf cm Facing upper left Facing left Facing forwards Facing upwards 1 When using flush mount box option Model No VL MB524 Attach the doorphone to the flush mount box A Screws...

Page 11: ...on monitor attach the mounting bracket in the location shown below C Main monitor extension monitor installation position D 100 4 mm E 55 7 mm Installing the main monitor extension monitor 1 Attach the mounting bracket A to the wall securely R Install the mounting bracket on a vertical flat wall B C Screws accessory 2 D Hole in wall E 60 mm F 83 5 mm G 7 mm H 50 mm 2 Connect the wires R Connect th...

Page 12: ...monitor extension monitor 3 2 Line up the tab on the top of the bracket with the groove on the main monitor extension monitor and push the main monitor extension monitor down until it is secure Important R Do not connect the power cable Damage may occur Note R Do not remove the terminal cover prj_6905 en_gb book Page 12 Friday March 8 2019 2 29 PM ...

Page 13: ...Notes 13 prj_6905 en_gb book Page 13 Friday March 8 2019 2 29 PM ...

Page 14: ...Notes 14 prj_6905 en_gb book Page 14 Friday March 8 2019 2 29 PM ...

Page 15: ...Notes 15 prj_6905 en_gb book Page 15 Friday March 8 2019 2 29 PM ...

Page 16: ... Panasonic Corporation 2019 PNQX8844ZA C0319MM0 1006 Oaza Kadoma Kadoma shi Osaka 571 8501 Japan http www panasonic com prj_6905 en_gb book Page 14 Friday March 8 2019 2 29 PM ...

Reviews: