Wire type and length
Wiring run
Wire type
Diameter
Max. length
Connected device
(example: lobby
station or distributor)
«
Main monitor
ø 0.65 mm (22 AWG)
approx. 100 m
ø 1.2 mm (17 AWG)
approx. 200 m
Main monitor
«
Door bell
ø 0.5 mm - ø 1.2 mm
(24 AWG - 17 AWG)
According to
specification of
connected device.
Main monitor
«
Connection device for
option output (A
contact)
ø 0.5 mm - ø 1.2 mm
(24 AWG - 17 AWG)
According to
specification of
connected device.
Note the following when selecting wiring
*1 Use 2-conductor (solid copper) wiring with a PE (polyethylene)-insulated PVC jacket.
Mid-capacitance, non-shielded cable is recommended.
R
A certified power supply wiring has to be used with this equipment. The relevant national
installation and/or equipment regulations shall be considered. A certified power supply wiring not
lighter than ordinary polyvinyl chloride flexible wiring according to IEC 60227 shall be used.
*2 When using a door bell, select a device that meets the following guidelines:
R
Connection device for option input terminal (IN1/IN2):
– Input method: No-voltage contact
– Open-circuit voltage between terminals: DC 10 V to 22 V
– Detection definite time: 0.1 second or more
– Resistance value: make: 500
W
or less, break: 150 k
W
or more
*3 When using a connection device for option output (A contact), select a device that meets the
following guidelines:
R
Connection device for option output (A contact) terminal (OUT1/OUT2):
– N/O dry closure contact
– 12 V AC/DC, less than 1 A
5