12
6.2.
Service tool mode
6.2.1.
How to access
1. Select [SRV-TOOL] in Service Mode.
2. Press [OK] button on the remote control.
6.2.2.
Display of SOS History
SOS History (Number of LED blinking) indication.
From left side; Last SOS, before Last, three occurrence before, 2nd occurrence after shipment, 1st occurrence after shipment.
This indication except 2nd and 1st occurrence after shipment will be cleared by [Self-check indication and forced to factory
shipment setting].
6.2.3.
POWER ON Time, On/Off
Note : To display TIME/COUNT menu, highlight position, then press MUTE for 3 seconds.
Time : Cumulative power on time, indicated hour : minute by decimal
On/Off : Number of On/Off switching by decimal
Note : This indication will not be cleared by either of the self-checks or any other command.
6.2.4.
Exit
Disconnect the AC cord from wall outlet or switch off the power with [ Power ] button on the main unit.
Summary of Contents for VIERA TX-42AS650B
Page 27: ...27 8 3 Specification of EMI countermeasures 8 3 1 Felt on Back Cover ...
Page 28: ...28 8 3 2 Felt on Back Cover 8 3 3 Felt on Key Button ...
Page 29: ...29 8 3 4 Felt on AC INLET 8 3 5 Felt on BOTTOM AV BRACKET ...
Page 30: ...30 8 3 6 WORK INSTRUCTIONS FOR GASKET POSTING 8 3 7 WORK INSTRUCTIONS FOR GASKET POSTING ...
Page 31: ...31 8 3 8 WORK INSTRUCTIONS FOR PET AL Tape POSTING ...
Page 35: ...35 11 Wiring Connection Diagram 11 1 Wiring Diagram ...
Page 37: ...37 ...