![Panasonic Viera TH-P42VT30Z Service Manual Download Page 3](http://html.mh-extra.com/html/panasonic/viera-th-p42vt30z/viera-th-p42vt30z_service-manual_1511536003.webp)
3
1 Safety Precautions
1.1.
General Guidelines
1. When conducting repairs and servicing, do not attempt to modify the equipment, its parts or its materials.
2. When wiring units (with cables, flexible cables or lead wires) are supplied as repair parts and only one wire or some of the
wires have been broken or disconnected, do not attempt to repair or re-wire the units. Replace the entire wiring unit instead.
3. When conducting repairs and servicing, do not twist the Fasten connectors but plug them straight in or unplug them straight
out.
4. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
5. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly
installed.
6. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.
1.2.
Touch-Current Check
1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check.
2. Connect a measuring network for touch currents between each exposed metallic part on the set and a good earth ground
such as a water pipe, as shown in Figure 1.
3. Use Leakage Current Tester (Simpson 228 or equivalent) to measure the potential across the measuring network.
4. Check each exposed metallic part, and measure the voltage at each point.
5. Reserve the AC plug in the AC outlet and repeat each of the above measure.
6. The potential at any point (TOUCH CURRENT) expressed as voltage U
1
and U
2
, does not exceed the following values:
For a. c.: U
1
= 35 V (peak) and U
2
= 0.35 V (peak);
For d. c.: U
1
= 1.0 V,
Note:
The limit value of U
2
= 0.35 V (peak) for a. c. and U
1
= 1.0 V for d. c. correspond to the values 0.7 mA (peak) a. c. and 2.0
mA d. c.
The limit value U
1
= 35 V (peak) for a. c. correspond to the value 70 mA (peak) a. c. for frequencies greater than 100 kHz.
7. In case a measurement is out of the limits specified, there is a possibility of a shock hazard, and the equipment should be
repaired and rechecked before it is returned to the customer.
Figure 1
Summary of Contents for Viera TH-P42VT30Z
Page 20: ...20 7 4 No Picture ...
Page 34: ...34 ...
Page 35: ...35 ...
Page 36: ...36 ...
Page 42: ...42 ...
Page 44: ...44 11 3 Wiring 2 ...
Page 45: ...45 11 4 Wiring 3 11 5 Wiring 4 ...
Page 46: ...46 11 6 Wiring 5 ...
Page 47: ...Model No TH P42VT30Z Schematic Diagram Note S 1 ...
Page 48: ...Model No TH P42VT30Z Replacement Parts List Note S 2 ...
Page 49: ...Model No TH P42VT30Z P Board 1 4 S 3 ...
Page 50: ...Model No TH P42VT30Z P Board 2 4 S 4 ...
Page 51: ...Model No TH P42VT30Z P Board 3 4 S 5 ...
Page 52: ...Model No TH P42VT30Z P Board 4 4 S 6 ...
Page 53: ...Model No TH P42VT30Z A Board 1 14 S 7 ...
Page 54: ...Model No TH P42VT30Z A Board 2 14 S 8 ...
Page 55: ...Model No TH P42VT30Z A Board 3 14 S 9 ...
Page 56: ...Model No TH P42VT30Z A Board 4 14 S 10 ...
Page 57: ...Model No TH P42VT30Z A Board 5 14 S 11 ...
Page 58: ...Model No TH P42VT30Z A Board 6 14 S 12 ...
Page 59: ...Model No TH P42VT30Z A Board 7 14 S 13 ...
Page 60: ...Model No TH P42VT30Z A Board 8 14 S 14 ...
Page 61: ...Model No TH P42VT30Z A Board 9 14 S 15 ...
Page 62: ...Model No TH P42VT30Z A Board 10 14 S 16 ...
Page 63: ...Model No TH P42VT30Z A Board 11 14 S 17 ...
Page 64: ...Model No TH P42VT30Z A Board 12 14 S 18 ...
Page 65: ...Model No TH P42VT30Z A Board 13 14 S 19 ...
Page 66: ...Model No TH P42VT30Z A Board 14 14 S 20 ...
Page 67: ...Model No TH P42VT30Z K S and V Board S 21 ...
Page 68: ...Model No TH P42VT30Z C1 Board 1 2 S 22 ...
Page 69: ...Model No TH P42VT30Z C1 Board 2 2 S 23 ...
Page 70: ...Model No TH P42VT30Z C2 Board 1 2 S 24 ...
Page 71: ...Model No TH P42VT30Z C2 Board 2 2 S 25 ...
Page 72: ...Model No TH P42VT30Z SN Board 1 6 S 26 ...
Page 73: ...Model No TH P42VT30Z SN Board 2 6 S 27 ...
Page 74: ...Model No TH P42VT30Z SN Board 3 6 S 28 ...
Page 75: ...Model No TH P42VT30Z SN Board 4 6 S 29 ...
Page 76: ...Model No TH P42VT30Z SN Board 5 6 S 30 ...
Page 77: ...Model No TH P42VT30Z SN Board 6 6 S 31 ...
Page 78: ...Model No TH P42VT30Z SS Board 1 2 S 32 ...
Page 79: ...Model No TH P42VT30Z SS Board 2 2 and SS2 Board S 33 ...
Page 80: ...Model No TH P42VT30Z P Board Foil Side S 34 ...
Page 81: ...Model No TH P42VT30Z P Board Component Side S 35 ...
Page 82: ...Model No TH P42VT30Z A Board Foil Side S 36 ...
Page 83: ...Model No TH P42VT30Z A Board Component Side S 37 ...
Page 84: ...Model No TH P42VT30Z K S and V Board S 38 ...
Page 85: ...Model No TH P42VT30Z C1 Board S 39 ...
Page 86: ...Model No TH P42VT30Z C2 Board S 40 ...
Page 87: ...Model No TH P42VT30Z SN Board Foil Side S 41 ...
Page 88: ...Model No TH P42VT30Z SN Board Component Side S 42 ...
Page 89: ...Model No TH P42VT30Z SS Board Foil Side S 43 ...
Page 90: ...Model No TH P42VT30Z SS Board Component Side S 44 ...
Page 91: ...Model No TH P42VT30Z SS2 Board S 45 ...
Page 132: ...Model No TH P42VT30Z Exploded View 1 S 86 ...
Page 133: ...Model No TH P42VT30Z Exploded View 2 S 87 ...
Page 134: ...Model No TH P42VT30Z Packing 1 S 88 ...