20
9.2.6.
Remove the P-Board
Caution:
To remove P.C.B. wait 1 minute after power was off for
discharge from electrolysis capacitors.
1. Unlock the tapes to free the cables
2. Disconnect the connectors (P2, P6, P11 and P35).
3. Remove the screws (
×
5 ,
×
1
) and remove the P-
Board.
9.2.7.
Remove the A-Board
1. Unlock the hooks and the tapes to free the cables.
2. Disconnect the connectors (A1, A6 and A12).
3. Disconnect the USB cable (JK8605).
4. Disconnect the flexible cables (A20, A31, A32 and A33).
5. Remove the screws (
×
4 ).
6. Remove the Side shield metal.
7. Remove the A-Board.
8. Remove the screws (
×
4
) and remove the A-Board
mount metals.
9.2.8.
Remove the Control unit assy
1. Unlock the tape to free the cables.
2. Disconnect the connector (C14).
3. Remove the claws (
×
2
) and remove the Control unit
assy.
9.2.9.
Remove the Speakers
1. Unlock the hooks and the tapes to free the cables.
2. Disconnect the Speaker terminal.
3. Remove the screws (
×
2
each) and remove the
Speakers (L, R).
9.2.10. Remove the SU-Board
1. Disconnect the flexible cables (SU1, SU2, SU3, SU4 and
SU5) connected to the SU-Board.
2. Disconnect the flexible cable (SU11-SD11) and the bridge
connector (SC41-SU41).
3. Remove the screws (
×
3 ,
×
1
) and remove the SU-
Board.