1 Safety Precautions
1.1.
General Guidelines
1. When conducting repairs and servicing, do not attempt to modify the equipment, its parts or its materials.
2. When wiring units (with cables, flexible cables or lead wires) are supplied as repair parts and only one wire or some of the
wires have been broken or disconnected, do not attempt to repair or re-wire the units. Replace the entire wiring unit instead.
3. When conducting repairs and servicing, do not twist the Faston connectors but plug them straight in or unplug them straight
out.
4. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
5. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly
installed.
6. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.
1.1.1.
Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the
two prongs on the plug.
2. Measure the resistance value, with an ohmmeter,
between the jumpered AC plug and each exposed metal-
lic cabinet part on the equipment such as screwheads,
connectors, control shafts, etc. When the exposed metal-
lic part has a return path to the chassis, the reading
should be between 1Mohm and 5.2Mohm.
When the exposed metal does not have a return path to
the chassis, the reading must be
.
1.1.2.
Leakage Current Hot Check (See
Figure 1.)
1. Plug the AC cord directly into the AC outlet. Do not use
an isolation transformer for this check.
2. Connect a 1.5kohm, 10 watts resistor, in parallel with a
0.15
μ
F capacitors, between each exposed metallic part
on the set and a good earth ground such as a water pipe,
as shown in Figure 1.
3. Use an AC voltmeter, with 1000 ohms/volt or more sensi-
tivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the volt-
age at each point.
5. Reverse the AC plug in the AC outlet and repeat each of
the above measurements.
6. The potential at any point should not exceed 0.75 volts
RMS. A leakage current tester (Simpson Model 229 or
equivalent) may be used to make the hot checks, leakage
current must not exceed 1/2 milliamp. In case a measure-
ment is outside of the limits specified, there is a possibility
of a shock hazard, and the equipment should be repaired
and rechecked before it is returned to the customer.
Figure 1
Summary of Contents for Viera TC-P54Z1
Page 24: ...24 6 4 No Picture ...
Page 44: ...44 9 1 4 Adjustment Volume Location 9 1 5 Test Point Location ...
Page 56: ...56 11 3 Wiring Tuner box 2 ...
Page 57: ...57 11 4 Wiring Display unit 1 ...
Page 58: ...58 11 5 Wiring Display unit 2 ...
Page 59: ...59 11 6 Wiring Display unit 3 ...
Page 60: ...60 ...
Page 61: ...61 12 Schematic Diagram 12 1 Schematic Diagram Note ...
Page 148: ...148 ...
Page 150: ...150 14 1 2 Exploded view 2 Display unit 1 ...
Page 151: ...151 14 1 3 Exploded view 3 Display unit 2 ...
Page 152: ...152 14 1 4 Exploded view 4 Wireless unit Transmitter ...
Page 153: ...153 14 1 5 Exploded view 5 Wireless unit Recevier ...
Page 154: ...154 14 1 6 Packing 1 ...
Page 155: ...155 14 1 7 Packing 2 ...
Page 156: ...156 14 1 8 Packing 3 ...
Page 157: ...157 14 1 9 Packing 4 ...
Page 158: ...158 14 1 10 Packing 5 Pedestal ...
Page 159: ...159 14 1 11 Packing 6 ...
Page 160: ...160 14 1 12 Packing 7 ...
Page 161: ...161 14 1 13 Packing 8 ...
Page 168: ...168 14 2 Electrical Replacement Parts List 14 2 1 Replacement Parts List Notes ...
Page 222: ...Caution Sheet TRANSMISSION RECEIVER UNIT ...
Page 224: ...P FILTER Board SCREW THEL071J SCREW THEC108J SARCON SHEET TMKK362 SARCON SHEET TMKK362 ...
Page 227: ...4 Location of SARCON Sheet 260 mm 10 2 80 mm 3 1 100 mm 3 9 200 mm 7 8 Sarcon sheet ...