27
9 Measurements and Adjustments
9.1.
Adjustment
9.1.1.
Vsus selection
Caution:
When Plasma panel or A-board is replaced, Vsus should be set to LOW or HIGH.
Procedure
1. Go into main item [VSUS] in Service Mode. LOW or HIGH will be displayed.
2. Press [OK] button to go to TEST stage.
White pattern without On-Screen Display will be displayed during TEST and CONF stage. Press [5] button to display the
On-Screen Display.
3. Press [VOL (-)] button to set to LOW.
4. In LOW setting
a. If no several dead pixel is visible remarkably in white pattern, press [3] button to go to CONF stage.
b. If the several dead pixels are visible remarkably in white pattern, Set to HIGH by press [VOL (+)] button. Press [3] button
to go to CONF stage if the symptom is improved.
5. Press [OK] button in CONF stage to store LOW or HIGH.
6. Exit Service Mode by pressing [Power] button.
Summary of Contents for VIERA TC-P54S2
Page 19: ...19 6 4 No Picture ...
Page 30: ...30 ...
Page 31: ...31 ...
Page 32: ...32 ...
Page 38: ...38 ...
Page 40: ...40 11 3 Wiring 2 ...
Page 41: ...41 11 4 Wiring 3 ...
Page 42: ...42 ...
Page 43: ...43 12 Schematic Diagram 12 1 Schematic Diagram Note ...
Page 74: ...74 A B C D E F G H I 1 2 3 4 5 6 P BOARD COMPONENT SIDE ETX2MM807ASH ...
Page 86: ...86 14 1 2 Exploded View 2 ...
Page 87: ...87 14 1 3 Accessories ...
Page 88: ...88 14 1 4 Mechanical Replacement Parts List ...
Page 91: ...91 14 2 Electrical Replacement Parts List 14 2 1 Replacement Parts List Notes ...