23
7.19. Remove the Plasma panel sec-
tion from the Cabinet assy
(glass)
1. Remove the cabinet assy and the plasma panel fastening
screws (
×
2 ).
2. Remove the claw (
×
2 ).
3. Remove the Rear cover hook holders (L, R).
4. For leaving the plasma panel from the front frame, pull the
bottom of the cabinet assy forward, lift, and remove.
7.20. Remove the S-Board
1. Remove the screws (
×
2
) and remove the S-Board
unit.
2. Disconnect the connector (S2).
3. Remove the screw (
×
1
).
4. Remove the S-Board from the Power button bracket.
5. Remove the claws (
×
2 ).
6. Remove the Power button from the Power button bracket.