24
9.2.23. Remove the Contact metals
1. Remove the screws (
×
16 ).
2. Remove the Contact metal side (L, R).
3. Remove the screws (
×
15 ).
4. Remove the Contact metal bottom.
9.2.24. Remove the C1-Board
1. Disconnect the flexible cables (CB1, CB2, CB3, CB4 and
CB5).
2. Disconnect the flexible cable (C10).
3. Disconnect the connectors (C14 and C18).
4. Remove the screws (
×
4
) and remove the C1-Board.
9.2.25. Remove the C2-Board
1. Disconnect the flexible cables (CB6, CB7, CB8, CB9,
CB10 and CB11).
2. Disconnect the flexible cables (C20, C21 and C26).
3. Disconnect the connectors (C25 and C28).
4. Remove the screws (
×
6
) and remove the C2-Board.
9.2.26. Remove the C3-Board
1. Disconnect the flexible cables (CB12, CB13, CB14 and
CB15).
2. Disconnect the flexible cables (C31 and C36).
3. Remove the screws (
×
4
) and remove the C3-Board.
9.2.27. Replace the Plasma panel
Caution:
Place the Plasma panel on a flat surface of a table
(covered by a soft cloth) and a cushion.
A new Plasma panel itself without Contact metals is fragile.
To avoid the damage to new Plasma panel, carry a new
Plasma panel taking hold of the Contact metals.
1. Place a carton box packed a new Plasma panel on the
flat surface of the work bench.
2. Open a box and without taking a new Plasma panel.
3. Attach the Cabinet assy and each P.C.Board and so on,
to the new Plasma panel.