8.2.17. Remove the C1-Board
1. Disconnect the flexible cables (CB1, CB2, CB3, CB4,
CB5, CB6 and CB7).
2. Disconnect the flexible cable (C10).
3. Remove the screws (
×
5
) and remove the C1-Board.
8.2.18. Remove the C2-Board
1. Disconnect the flexible cables (CB8, CB9, CB10, CB11,
CB12, CB13, CB14 and CB15).
2. Disconnect the flexible cables (C20, C21 and C22).
3. Disconnect the connector (C25).
4. Remove the screws (
×
6
) and remove the C2-Board.
8.2.19. Replace the Plasma panel
Caution:
Place the Plasma panel on a flat surface of a table (cov-
ered by a soft cloth) and a cushion.
A new Plasma panel itself without Contact metals is fragile.
To avoid the damage to new Plasma panel, carry a new
Plasma panel taking hold of the Contact metals.
1. Place a carton box packed a new Plasma panel on the
flat surface of the work bench.
2. Open a box and without taking a new Plasma panel.
3. Attach the Cabinet assy and each P.C.Board and so on,
to the new Plasma panel.