23
8 Measurements and Adjustments
8.1.
Adjustment Procedure
8.1.1.
Driver Set-up
8.1.1.1.
Item / Preparation
1. Input a white signal to plasma video input.
2. Set the picture controls as follows.
Picture menu: Vivid
Normal: Set
Aspect: Full
Caution
1. First perform Vsus adjustment.
2. The Vscn voltages are measured from the Vad (Vad_base), but may be measured from the GND (GND_base) in an
unavoidable case.
8.1.1.2.
Adjustments
Adjust driver section voltages referring the panel data on the panel data label.
Check or adjust the following voltages with the multimeter.
*See the Panel label.
Name
Test Point
Voltage
Volume
Remarks
Vsus
TPVSUS (SS)
Vsus ± 2V
R737 (P)
*
Ve
TPVE (SS)
Ve ± 2.5V
Fixed
*
Vset
TPVSET (SC)
290V ± 9V
Fixed
Vad
TPVAD (SC)
-180V ± 2V
VR16600 (SC)
Vscn
TPVSCN (SC)
Vad_base : 145V ± 4V
GND_base : - 35V ± 6V
Fixed
Vda
TPVDA (P)
60V + 1V, - 2V
Fixed
All manuals and user guides at all-guides.com
Summary of Contents for Viera TC-50PX14
Page 15: ...15 6 4 No Picture All manuals and user guides at all guides com ...
Page 27: ...27 All manuals and user guides at all guides com ...
Page 28: ...28 All manuals and user guides at all guides com ...
Page 34: ...34 10 3 Wiring 2 All manuals and user guides at all guides com ...
Page 35: ...35 10 4 Wiring 3 All manuals and user guides at all guides com ...
Page 36: ...36 10 5 Wiring 4 All manuals and user guides at all guides com a l l g u i d e s c o m ...
Page 82: ...82 All manuals and user guides at all guides com ...
Page 84: ...84 13 1 2 Accessories All manuals and user guides at all guides com ...
Page 85: ...85 13 1 3 Mechanical Replacement Parts List All manuals and user guides at all guides com ...