background image

Digital Link cable

Digital Link cable

Digital Link cable

DIGITAL LINK Connection

For VF1H/VF2H/VF2 model

DVI cable

1台目

2台目

1台目

2台目

Daisy Chain Connection 1

ET-

YFB200

18

Max

10units

If contents have HDCP signal,

Max 8units is available.

In case of Digital Link input

In case of DVI input

Third or more monitor

Third or more monitor

First monitor

Second monitor

First monitor

Second monitor

Summary of Contents for VF2H Series

Page 1: ...Construction Manual Video Wall ...

Page 2: ...et 4 6 Installation of mounting bracket 7 Cautions of Video Wall installation 9 Embedding condition 13 Connection to power source 17 Daisy Chain Connection Remote controller IR signal outreach distance 18 24 Picture adjustment Color Calibration 25 Maintenance Maintenance 26 Contents ...

Page 3: ...king Procedure 3 Unpacking Joint front and back Each 2 points Accessory parts Remove Joint Total 4 Take out accessory parts and cushions Remove upper carton case and front cushions Remove a protection bag Front Side ...

Page 4: ...4 Cautions 1 Please do not move with the monitor as an upswing or a downswing ...

Page 5: ...hold any part except the handles Do not touch top down left right side and also surface of the monitor Do not stand on the floor directly with surface or rear side of the monitor Do not make impacts to the monitor Do not twist the monitor Handle No Good OK ...

Page 6: ... support them 3 Ensure the bracket used can be adjusted upward downward to the left and right forward and backward 4 When installing or moving ensure the bracket does not interfere with the back of the monitor cable guides and other structures 5 Ensure the bracket is constructed so that the monitor can easily be removed 6 Please do not distort the monitor If you can not install in the same way as ...

Page 7: ...llation of mounting bracket 1 There are L type protection board downside and protection film monitor surface Please remove them 16mm longer than the thickness of the mounting bracket and tighten them securely ...

Page 8: ...alls TH 55VF2H VF2 4row 5column TH 55VF1H 5row 6column TH 55LFV9 LFV8 9row 11column Column Row Installation of mounting bracket 2 Please set a position dial up down left and right of the starting bracket to eccentric position of installation direction side not a center default position for example ...

Page 9: ...Please do not press panel active area and corner Please press center edge of right and left Please press vertically to the panel Please increase power in right and left equality There is a possibility that if pressure is added on the bezel towards outside the bezel will be distorted The bezel will be open by 20N pressure Please add a soft pressure vertically to the panel ...

Page 10: ...After turning on the monitor slightly expands due to heat When installing multiple monitors with fixed outer most peripheries space 0 5 mm between monitors above below to the left and right sides of each monitor must be secured to account for expansion due to heat Space between sets same for above below to the left and right directions ...

Page 11: ...sition Please do not adjust to flat each monitor surface using some material such as PLATE This case distortion is added to the monitor and there is a possibility some picture trouble happen to the monitor Please do not use a hole of rear monitor corner except for Panasonic option bracket such as TY VK55LV1 TY VK55LV2 ...

Page 12: ...on condensation Note In case of LFV8 model 20 80 Non condensation Please secure space as follows 1 Stand alone installation Secure 100 mm or more space above below to the left and right and 50 mm or more behind the monitor 2 Multi installation Secure 100 mm or more space above below to the left and right and 150 mm or more behind the monitor ...

Page 13: ... D C E B Embedding 1 Embedding space stand alone horizontal installation 13 Unit mm Secure space as follows Ambient Condition Temperature 0ー40 Humidity 10 90 Non condensation Note In case of LFV8 model from 20 to 80 Non condensation ...

Page 14: ...A B C D E 14 Embedding 2 Embedding space stand alone vertical installation Unit mm Secure space as follows Ambient Condition Temperature 0ー40 Humidity 10 90 Non condensation Note In case of LFV8 model from 20 to 80 Non condensation ...

Page 15: ... B C D E 15 Embedding 3 Embedding space multi system horizontal installation Unit mm Secure space as follows Ambient Condition Temperature 0ー40 Humidity 10 90 Non condensation Note In case of LFV8 model from 20 to 80 Non condensation ...

Page 16: ...A B C D E 16 Embedding 4 Embedding space multi system vertical installation Unit mm Secure space as follows Ambient Condition Temperature 0ー40 Humidity 10 90 Non condensation Note In case of LFV8 model from 20 to 80 Non condensation ...

Page 17: ...wer source 17 AC Power Cord J Model W Model U Model C Model Use only the AC power cord included and connect securely Never use a power cord other than the one included as it may lead to a smoke emission and or fire due to insufficient contact Caution ...

Page 18: ...2H VF2 model DVI cable 1台目 2台目 1台目 2台目 Daisy Chain Connection 1 ET YFB200 18 Max 10units If contents have HDCP signal Max 8units is available In case of Digital Link input In case of DVI input Third or more monitor Third or more monitor First monitor Second monitor First monitor Second monitor ...

Page 19: ...AL LINK Connection For VF1H VF2H VF2 model 19 Daisy Chain Connection 2 Max 10units If contents have HDCP signal Max 8units is available In case of HDMI input In case of Display Port input Third or more monitor Third or more monitor First monitor Second monitor First monitor Second monitor ...

Page 20: ... cable 1台目 2台目 Display Port cable 20 Daisy Chain Connection 3 Max 10units If contents have HDCP signal Max 8units is available Third or more monitor First monitor Second monitor Display Port Daisy Chain Connection For LFV8 LFV9 model ...

Page 21: ... DVI cable DVI cable 21 Daisy Chain Connection 4 Max 10units If contents have HDCP signal Max 8units is available Third or more monitor First monitor Second monitor DVI Daisy Chain Connection For LVF8 LVF9 model ...

Page 22: ... from PC please use the RS232C straight cable 22 Daisy Chain Connection 5 First monitor Second monitor First monitor Second monitor Max 100units Max 100units Third or more monitor Third or more monitor Straight cable PC PC In case of the Digital Link daisy chain connection no need to connect the RS232C cable But connection limitation is same as the Digital Link daisy chain connection ...

Page 23: ...Max 100 units VF1H VF2H VF2 model Max 62 units LFV8 LFV9 model In case of the Digital Link daisy chain connection of the VF1H VF2H VF2 model no need to connect the IR daisy chain cable stereo mini plug But connection limitation is same as the Digital Link daisy chain connection EXTERNAL IR CONNECTION ...

Page 24: ...r IR signal 24 In case of using external IR receiver the remote controller IR signal outreach distance Is about 7m Remote controller IR signal outreach distance We recommend to use LAN or RS232C to control the monitor ...

Page 25: ...g color sensor Auto color adjustment using camera 25 Please refer operation manual of Video Wall Manager Software and TY VUK10 Support color calibration Camera finder PC Video Wall Manager Software TY VUK10 Auto color adjustment Upgrade Kit ...

Page 26: ...maintain normal operation check for the following regularly Remove dust if it collects at the air vents part indicated in pink of the monitor If left as is a malfunction may occur due to temperature rise caused by insufficient ventilation ...