background image

14 

MAINTENANCE

 

• 

In order to maintain the optimum output of the 

module, quality and safety, please conduct 
periodic inspection or cleaning.

 

• 

It is also recommended to inspect the electrical 

and mechanical connections annually.

 

• 

If you need electrical or mechanical inspection 

or maintenance, it is recommended to have a 
licensed authorized professional carry out the 
inspection or maintenance to avoid the hazards 
of electric shock or injury.

 

ANTI

-

REFLECTION GLASS SURFACE 

CLEANING

 

• 

Light dirt that does not shield light completely 

does not significantly degrade power genera-
tion performance, but if the module surface 
becomes dirty, it may reduce output power, 
malfunction or hotspot may occur.

 

• 

It is recommended to clean the surface of the 

module with water and a soft cloth or sponge.

 

• 

When cleaning with neutral glass detergent or 

weak alkaline glass detergent, it is recommend-
ed to start with smallest area and from the 
edge of solar module in order to check no 
damage occurs to the glass.

 

• 

After that, clean surface of glass with wet and 

clean cloth.

 

• 

Recommended detergent: "Glass Magiclean"1) 

or "Windex® Origi

-

nal"2) 

 

1) Glass Magiclean is a trademark of Kao Corpo-
ration. 

 

2) Windex® is a trademark of SC Johnson & 
Son,Inc. 

 

• 

It is recommended to read carefully the manu-

als of detergent and understand notes on usage 
and first

-

aid treatment.

 

• 

To remove persistent dirt, the module can be 

washed with a micro

-

fiber cloth and ethanol.

 

• 

Never use abrasive detergent, strong alkaline 

detergent, strong acid detergent or a detergent 
which forms a protective layer on the surface of 
the glass to clean any part of the module. The 
performance of a solar module may be re-
duced. Please be very careful since the guaran-
tee will not cover damages caused by deter-
gents.

 

• 

When cleaning the PV module, please do not 

put detergent on junction box or connector. If 
deter

-

gents and chemical substances ad

-

here, 

junction box and connector may be deteriorat-
ed or damaged. 

 

DISPOSAL OF OLD EQUIPMENT

 

This symbol on the products, and/or accompanying 
documents means

 

that used electrical and electronic 

products must not be mixed with general household 

waste. 

 

For proper treatment, recovery and recycling of old 
products, please take them

 

to applicable collection 

points in accordance with your national legislation.

 

For more information about collection and recycling, 
please contact your local municipality.

 

Penalties may be applicable for incorrect disposal of 
this waste, in accordance with national legislation.

 

DISCLAIMER OF LIABILITY

 

Panasonic does not assume responsibility and ex-
pressly disclaims liability for loss, damage, or expense 
arising out of, or in any way connected with installa-
tion, operation, use, or maintenance by using this 
manual.  

 

Panasonic assumes no responsibility for any infringe-
ment of patents or other rights of third parties, which 
may result from use of modules. 

 

No license is granted by implication or 
under any patent or patent rights. The 
information in this manual is believed 
to be reliable, but does not constitute 
an expressed and/or implied guaran-
tee. 

 

As part of our policy of continuous improvement

Panasonic reserves the right to make changes to the 
product, specifications, or manual at any time without 
prior notice.

 

The return of any modules will not be accepted by 
Panasonic unless prior written authorization has been 
given by Panasonic.

 

CUSTOMER SERVICES

 

For further information, please visit eu

-

solar.panasonic.net or contact a Panasonic Author-
ized Representative.

 

 

© SANYO Electric Co., Ltd. 2018 

 

SANYO is part of the Panasonic Group and is in charge 
of the manufacturing process for HIT

TM

 

 

IM002

-

0918

-

2

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for VBHNxxxSJ25 series

Page 1: ...s or registered trademarks of respective companies General Installation Manual VBHNxxxSJ25 series VBHNxxxSJ40 series VBHNxxxSJ46 series VBHNxxxSJ47 series Photovoltaic Module HITTM Thank you for choosing Panasonic photovoltaic module HITTM Please read this manual completely before you install or use of HITTM With proper operation and maintenance HITTM will provide you with clean renewable solar el...

Page 2: ...s are connected in series pro ducing higher voltages The shock hazard increases as modules with nominal open circuit voltage Voc in excess of 45 V and or modules rated for maximum system voltage in excess of 45 V Wear suitable clothing gloves and guards to prevent from direct contact with 30 VDC or greater Work only in dry conditions with dry modules and dry tools Children and unauthorized persons...

Page 3: ...ge ratings conductor capacities fuse sizes and size of controls connected to the module out put 3 The current output for the modules shown in the Specifications is measured at Standard Test Conditions These conditions may not be fre quently observed in actual practice Table 1 1 Model Specifications Silicone hetero junction Mono crystalline Silicon amorphous silicon hetero junction Model VBHN240SJ2...

Page 4: ...he positions of the holes are all symmetrical against the center of the module Front side Figure 1 1 Module dimensions VBHNxxxSJ25 Dimension in mm Back side Side Figure 1 1 a Optional Mounting Range A Note Fixing span must not exceed 1040mm Figure 1 1 b Optional Mounting Range B Note Fixing span must not exceed 1040mm ...

Page 5: ...rotection rating A 15 Factory Installed Bypass Diode pcs 4 Length x Width x Height mm 1463 x 1053 x 46 Weight kg 18 Section A A Section B B Note A module is installed using 4 points symmetrical mounting within setting range shaded Front side Figure 1 2 Module dimensions VBHNxxxSJ40 Dimension in mm Back side Side Table 1 2 Model Specifications Silicone hetero junction Mono crystalline Silicon amorp...

Page 6: ...ies pcs 88 Cell Type Silicon hetero junction Maximum System Voltage Vsys V 1000 Maximum over current protection rating A 15 Factory Installed Bypass Diode pcs 4 Length x Width x Height mm 1463 x 1053 x 35 Weight kg 18 Table 1 3 Model Specifications Silicone hetero junction Mono crystalline Silicon amorphous silicon hetero junction The positions of the holes are all symmetrical against the center o...

Page 7: ...e Vsys V 1000 Maximum over current protection rating A 15 Factory Installed Bypass Diode pcs 4 Length x Width x Height mm 1590 x 1053 x 35 Weight kg 19 Table 1 4 Model Specifications Silicone hetero junction Mono crystalline Silicon amorphous silicon hetero junction Section A A Section B B Note A module is installed using 4 points symmetrical mounting within setting range shaded Front side Figure ...

Page 8: ...he shaded area This may cause unde sirable heating to occur The use of a diode to bypass the shaded area can minimize both heating and array current reduction All modules are equipped with factory installed bypass diodes The factory installed diodes provide proper circuit protection for the sys tems within the specified system voltage so that you do not need any other additional bypass diodes Spec...

Page 9: ...ACKING AND HANDLING Do not hit the back sheet of a module by the connector when unpacking and handling Please do not expose the connector the rain water and dust To avoid the damage of the back sheet by the connector fix the cables to the frame with tape after unpacking refer Figure 4 Do not handle modules by their cables or junction box Handle them by the frame with both hands in any situation Th...

Page 10: ...ions that could result in deterioration or corrosion Clearance 100mm between the roof surface and module frame is required to allow cooling air to circulate around the back of the module This also allows any condensation or moisture to dissipate Install modules so that air can circulate between the roof and the module Do not contact a tip of a mounting bolt to back sheet of the module when fixing ...

Page 11: ...mp A 2 places Mounting Structure Rail 38mm 38mm 46mm 34mm For VBHNxxxSJ40 Solar Module Module Mounting Structure Rail M8 Bolt Spring washer M8 Nut Flat washer Flat washer Spring washer Figure 5 2 Module Installation VBHNxxxSJ40 Installation reference ...

Page 12: ...Solar Module Metal clamp B 2 places Metal clamp A 2 places Mounting Structure Rail 38mm 38mm 35mm 11mm Figure 5 3 Module Installation VBHNxxxSJ46 VBHNxxxSJ47 For VBHNxxxSJ47 Solar Module Metal clamp B 2 places Metal clamp A 2 places Mounting Structure Rail 38mm 38mm 35mm 11mm For VBHNxxxSJ46 Installation reference ...

Page 13: ... tempera ture conditions to ensure compliance with maximum system voltage limitations Do not connect module in parallel without using connection devices that connect to ap propriate FUSE for each series string or each module For the installation of connection devices refer to the installation manual of connection devices Do not connect modules in parallel without maximum over current protection AR...

Page 14: ...l not cover damages caused by deter gents When cleaning the PV module please do not put detergent on junction box or connector If deter gents and chemical substances ad here junction box and connector may be deteriorat ed or damaged DISPOSAL OF OLD EQUIPMENT This symbol on the products and or accompanying documents means that used electrical and electronic products must not be mixed with general h...

Reviews: