background image

H: 900 mm (2 ft. 11 7/16 in.)
H: 812.8 mm (2 ft. 8 in.)

V: 940 mm (3 ft. 1 in.)

H: 518 mm (20 3/8 in.)
H: 440 mm (17 11/32 in.)

Center of the electronic board (screen)

UB-5865

Center of the electronic board (screen) 

UB-5365

Panasonic assumes no responsibility for injuries or property damage resulting 

from failures arising out of improper installation or operation inconsistent with this 

documentation.

For Your Safety

To prevent severe injury and loss of life, read this section carefully before using the 

unit to ensure proper and safe operation of your unit.

This section explains the graphic symbols used in this manual.

 

Denotes a potential hazard that could result in 

serious injury or death.

Denotes hazards that could result in minor 

injury or damage to the unit.

These symbols are used to alert operators to a specific 

operating procedure that must not be performed.

These symbols are used to alert operators to a specific 

operating procedure that must be emphasized in order 

to operate the unit safely.

WARNING

CAUTION

WARNING

Notes in the operating instructions or notes of labels on the 

cabinet, chassis or parts should be observed.

Be sure to use the specified parts for the installation. Otherwise, 

it may cause fire, electric shock or injury.

Plug the power cord firmly into an AC outlet. Otherwise, it can 

cause fire or electric shock.

Safety check must be done by qualified service personnel after 

installing this option.

Have the unit installed, removed and disposed of only by 

qualified service personnel.

If the unit is hung on a wall, confirm the wall must be capable of 

supporting at least the following weight.
1,568 N (160 kgf)

Be sure to disconnect the power cord while installing the unit. 

Otherwise, it may cause electric shock or injury.

To ensure safe operation the power cord supplied must be 

inserted into a standard three-prong AC outlet which is 

effectively grounded (earthed) through the normal wiring.

The fact that the equipment operates satisfactorily does not 

imply that the power point is grounded (earthed) and that the 

installation is completely safe. For your safety, if in any doubt 

about the effective grounding (earthing) of the power point, 

consult a qualified electrician.

Do not use damaged plugs or warped outlets. Otherwise, it may 

cause fire, electric shock, or short circuit.

During thunderstorms, do not touch the unit and plug. It may 

cause an electric shock.

Do not alter the unit or modify any parts. Alteration or 

modification can cause fire or electric shock.

CAUTION

Be sure to put on a glove to avoid electric shock or injury.

Confirm both sides of the screen are hung in the same height 

slots.

Make sure to tighten the height adjustment handles after 

adjusting the screen height.

Confirm the bolts of the unit are certainly caught by the wall 

mounting plate by pulling the unit after hanging the unit on the 

wall mounting plate if the unit is mounted on a wall.

After installing or moving the 

electronic board, lock the 

casters and set the fall-

prevention extension legs.

Move this unit with two persons. Otherwise, this unit may fall 

down and cause injury.

When using the stand, be sure to watch your step so that you do 

not bump into or trip over the fall-prevention extension legs.The 

label of precautions is attached to the stand UE-608005 (sold 

separately).

For your safety, connect the lead wire 

securely to the terminal.

(Refer to step 31.)

Locking the casters

(Push to lock)

Do not position the unit in a location where it is unstable.

Do not attach the electronic board to mortared walls. Accidental 

electric leakage from the wall mounting plate bolts to metal laths 

or wire laths can cause heat, smoke or fire.

Cautions for Wall Mounting 

Construction

Which method should be used to mount the electronic board depends greatly on 

the structure of the wall. The system to be mounted on the wall is heavy. Before 

proceeding with installation, therefore, consult with the building manager, 

maintenance engineer or designer to verify that the wall has a structure strong 

enough to support the weight of the system. For safety, install the electronic board 

only after thoroughly understanding the type of walls, the appropriate types of 

screws and the construction method.

Necessary Tools and Parts

Tools Required for Assembly

Phillips Head Screwdriver . . . . . . 1

Tools and Parts Required for Wall-Mounting Work

Drill, measuring tape, level, dust pump, hammer, torque driver (capable to specify 

torque*

1

)

*1 The range in which the torque can be specified is limited. Use the correct 

torque.  [Recommended tightening torque: 5.2 N•m (53 k

g

f•cm)]

Checkpoints to be Observed While Working

1

Work-Related Safety Precautions

Before mounting the electronic board, read through the following points, and 

take care to avoid accidents.

— To ensure that the work is accomplished safely and properly, make it a 

basic rule to strictly observe all other applicable aspects of safety control.

— If there is a chance that the unit has ended up being deformed or damaged 

by unexpected impact while it was being transported and installed, do not 

install it without taking appropriate measures. Otherwise, it may fall off the 

wall.

2

Concerning Installation

The electronic board is for indoor use. It cannot be used outdoors. Neither can 

it be installed or used in the following kinds of places.

— Places where it will be directly exposed to rain or water (including under 

the eaves of a house)

— Places with a lot of steam or grease such as manufacturing plants or 

kitchens, places with special environm

ents such as those with combustible 

atmospheres

— Seaborne or coastal places and places where corrosive gases are given off

— Places where the operating temperature range of the electronic board 

[temperature: 10 °C to 35 °C (50 °F to 95 °F), humidity: 30 % to 80 %] will 

be exceeded

To prevent deformation and discoloring, avoid installing the unit in places 

exposed to direct sunlight or near heating or cooling appliances, etc.

3

Concerning the Installation Surface

Avoid mounting the unit on a wall, which is not a principal structure 

component [a concrete wall which is at least 120 mm (4

3

/

4

in.) thick], with a 

plasterboard, plywood or other such co

nstruction since these walls are weak. 

If mounting on such a wall is unavoidable, reinforce the wall adequately (by 

ensuring that its ultimate strength will be at least as great as the specified pull-

out strength of the anchors).

4

Concerning the Screws and Bolts Used

When obtaining anchors and bolts locally, be absolutely sure that they satisfy 

the required specifications.

Use the values recommended by the manufacturer of the anchors used for 

the depth to which the anchors are to be embedded in the wall.

Use M6 bolts when the anchors have internal screw threads.

Ensure that the M6 bolt has a mated length of 9 mm (

11

/

32

in.) or longer. 

(Below)

Ensure that the M6 bolts do not strike 

the bottoms of the 

anchors, and check 

that they have been tightened up securely.

Recommended tightening torque: 5.2 N•m (53 k

g

f•cm)

5

Other Checkpoints

Make sure that the location is large enough to accommodate the electronic 

board.

Place the AC outlet in the position outlined below.

— Within 3 m (9ft. 10 

1

/

8

 in.) of the electronic board mounting position

— Not behind the electronic board

Anchor . . . . . . . . . . . . . . .  4
M6 Bolt. . . . . . . . . . . . . . .  4
Flat Washer . . . . . . . . . . .  4
Spring Washer . . . . . . . . .  4

The specified pull-out strength is required 

per anchor.

M6 anchor bolts are used when installing the 

electronic board on the wall.

[Specified pull-out strength: 784 N (80 k

g

f)]

UB-5365

Height:  greater than 1,480 mm (4 ft. 10

9

/

32

in.)

Width:  greater than 1,580 mm (5 ft. 2

7

/

32

in.)

UB-5865

Height:  greater than 1,480 mm (4 ft. 10

9

/

32

in.)

Width:  greater than 1,950 mm (6 ft. 4

25

/

32

in.)

M6 Bolt

Spring Washer

Installation Surface

Anchor (internal thread)
9 mm (

11

/

32

in.) or longer

Flat Washer [max. diameter of 16 mm (

5

/

8

in.)]

Wall-mounting and electronic board assembly

1

Use the template from the Installation Manual to mark 

the position on the wall.

2

Drill 4 holes in the wall.

3

Hammer in the anchors.

4

Fix electronic board accessories 

 and 

 (board 

attachments) to the wall with M6 screws.

5

Refer to steps 9 and on under “

 Assembling the 

Optional Stand and Electronic Board”.

Steps 19 to 23 and 32 are unnecessary.

A

B

C

A

B

C

H: 900 mm (2 ft. 11 7/16 in.)

H: 812.8 mm

(2 ft. 8 in.)

V: 940 mm 

(3 ft. 1 in.)

Make marks at   and   or   and  .

A

C

B

C

UB-5365̲PNQX5935ZA̲eng̲p2̲20121119.pdf   1   2012/11/19   15:33:25

Reviews: