H: 900 mm (2 ft. 11 7/16 in.)
H: 812.8 mm (2 ft. 8 in.)
V: 940 mm (3 ft. 1 in.)
H: 518 mm (20 3/8 in.)
H: 440 mm (17 11/32 in.)
Center of the electronic board (screen)
UB-5865
Center of the electronic board (screen)
UB-5365
•
Panasonic assumes no responsibility for injuries or property damage resulting
from failures arising out of improper installation or operation inconsistent with this
documentation.
For Your Safety
To prevent severe injury and loss of life, read this section carefully before using the
unit to ensure proper and safe operation of your unit.
•
This section explains the graphic symbols used in this manual.
Denotes a potential hazard that could result in
serious injury or death.
Denotes hazards that could result in minor
injury or damage to the unit.
These symbols are used to alert operators to a specific
operating procedure that must not be performed.
These symbols are used to alert operators to a specific
operating procedure that must be emphasized in order
to operate the unit safely.
WARNING
CAUTION
WARNING
■
Notes in the operating instructions or notes of labels on the
cabinet, chassis or parts should be observed.
■
Be sure to use the specified parts for the installation. Otherwise,
it may cause fire, electric shock or injury.
■
Plug the power cord firmly into an AC outlet. Otherwise, it can
cause fire or electric shock.
■
Safety check must be done by qualified service personnel after
installing this option.
■
Have the unit installed, removed and disposed of only by
qualified service personnel.
■
If the unit is hung on a wall, confirm the wall must be capable of
supporting at least the following weight.
1,568 N (160 kgf)
■
Be sure to disconnect the power cord while installing the unit.
Otherwise, it may cause electric shock or injury.
■
To ensure safe operation the power cord supplied must be
inserted into a standard three-prong AC outlet which is
effectively grounded (earthed) through the normal wiring.
■
The fact that the equipment operates satisfactorily does not
imply that the power point is grounded (earthed) and that the
installation is completely safe. For your safety, if in any doubt
about the effective grounding (earthing) of the power point,
consult a qualified electrician.
■
Do not use damaged plugs or warped outlets. Otherwise, it may
cause fire, electric shock, or short circuit.
■
During thunderstorms, do not touch the unit and plug. It may
cause an electric shock.
■
Do not alter the unit or modify any parts. Alteration or
modification can cause fire or electric shock.
CAUTION
■
Be sure to put on a glove to avoid electric shock or injury.
■
Confirm both sides of the screen are hung in the same height
slots.
■
Make sure to tighten the height adjustment handles after
adjusting the screen height.
■
Confirm the bolts of the unit are certainly caught by the wall
mounting plate by pulling the unit after hanging the unit on the
wall mounting plate if the unit is mounted on a wall.
■
After installing or moving the
electronic board, lock the
casters and set the fall-
prevention extension legs.
■
Move this unit with two persons. Otherwise, this unit may fall
down and cause injury.
■
When using the stand, be sure to watch your step so that you do
not bump into or trip over the fall-prevention extension legs.The
label of precautions is attached to the stand UE-608005 (sold
separately).
■
For your safety, connect the lead wire
securely to the terminal.
(Refer to step 31.)
Locking the casters
(Push to lock)
■
Do not position the unit in a location where it is unstable.
■
Do not attach the electronic board to mortared walls. Accidental
electric leakage from the wall mounting plate bolts to metal laths
or wire laths can cause heat, smoke or fire.
Cautions for Wall Mounting
Construction
Which method should be used to mount the electronic board depends greatly on
the structure of the wall. The system to be mounted on the wall is heavy. Before
proceeding with installation, therefore, consult with the building manager,
maintenance engineer or designer to verify that the wall has a structure strong
enough to support the weight of the system. For safety, install the electronic board
only after thoroughly understanding the type of walls, the appropriate types of
screws and the construction method.
■
Necessary Tools and Parts
Tools Required for Assembly
Phillips Head Screwdriver . . . . . . 1
Tools and Parts Required for Wall-Mounting Work
Drill, measuring tape, level, dust pump, hammer, torque driver (capable to specify
torque*
1
)
*1 The range in which the torque can be specified is limited. Use the correct
torque. [Recommended tightening torque: 5.2 N•m (53 k
g
f•cm)]
■
Checkpoints to be Observed While Working
1
Work-Related Safety Precautions
•
Before mounting the electronic board, read through the following points, and
take care to avoid accidents.
— To ensure that the work is accomplished safely and properly, make it a
basic rule to strictly observe all other applicable aspects of safety control.
— If there is a chance that the unit has ended up being deformed or damaged
by unexpected impact while it was being transported and installed, do not
install it without taking appropriate measures. Otherwise, it may fall off the
wall.
2
Concerning Installation
•
The electronic board is for indoor use. It cannot be used outdoors. Neither can
it be installed or used in the following kinds of places.
— Places where it will be directly exposed to rain or water (including under
the eaves of a house)
— Places with a lot of steam or grease such as manufacturing plants or
kitchens, places with special environm
ents such as those with combustible
atmospheres
— Seaborne or coastal places and places where corrosive gases are given off
— Places where the operating temperature range of the electronic board
[temperature: 10 °C to 35 °C (50 °F to 95 °F), humidity: 30 % to 80 %] will
be exceeded
•
To prevent deformation and discoloring, avoid installing the unit in places
exposed to direct sunlight or near heating or cooling appliances, etc.
3
Concerning the Installation Surface
•
Avoid mounting the unit on a wall, which is not a principal structure
component [a concrete wall which is at least 120 mm (4
3
/
4
in.) thick], with a
plasterboard, plywood or other such co
nstruction since these walls are weak.
If mounting on such a wall is unavoidable, reinforce the wall adequately (by
ensuring that its ultimate strength will be at least as great as the specified pull-
out strength of the anchors).
4
Concerning the Screws and Bolts Used
•
When obtaining anchors and bolts locally, be absolutely sure that they satisfy
the required specifications.
•
Use the values recommended by the manufacturer of the anchors used for
the depth to which the anchors are to be embedded in the wall.
•
Use M6 bolts when the anchors have internal screw threads.
•
Ensure that the M6 bolt has a mated length of 9 mm (
11
/
32
in.) or longer.
(Below)
•
Ensure that the M6 bolts do not strike
the bottoms of the
anchors, and check
that they have been tightened up securely.
•
Recommended tightening torque: 5.2 N•m (53 k
g
f•cm)
5
Other Checkpoints
•
Make sure that the location is large enough to accommodate the electronic
board.
•
Place the AC outlet in the position outlined below.
— Within 3 m (9ft. 10
1
/
8
in.) of the electronic board mounting position
— Not behind the electronic board
Anchor . . . . . . . . . . . . . . . 4
M6 Bolt. . . . . . . . . . . . . . . 4
Flat Washer . . . . . . . . . . . 4
Spring Washer . . . . . . . . . 4
The specified pull-out strength is required
per anchor.
M6 anchor bolts are used when installing the
electronic board on the wall.
[Specified pull-out strength: 784 N (80 k
g
f)]
UB-5365
Height: greater than 1,480 mm (4 ft. 10
9
/
32
in.)
Width: greater than 1,580 mm (5 ft. 2
7
/
32
in.)
UB-5865
Height: greater than 1,480 mm (4 ft. 10
9
/
32
in.)
Width: greater than 1,950 mm (6 ft. 4
25
/
32
in.)
M6 Bolt
Spring Washer
Installation Surface
Anchor (internal thread)
9 mm (
11
/
32
in.) or longer
Flat Washer [max. diameter of 16 mm (
5
/
8
in.)]
■
Wall-mounting and electronic board assembly
1
Use the template from the Installation Manual to mark
the position on the wall.
2
Drill 4 holes in the wall.
3
Hammer in the anchors.
4
Fix electronic board accessories
and
(board
attachments) to the wall with M6 screws.
5
•
Refer to steps 9 and on under “
■
Assembling the
Optional Stand and Electronic Board”.
•
Steps 19 to 23 and 32 are unnecessary.
A
B
C
A
B
C
H: 900 mm (2 ft. 11 7/16 in.)
H: 812.8 mm
(2 ft. 8 in.)
V: 940 mm
(3 ft. 1 in.)
•
Make marks at and or and .
A
C
B
C