Panasonic U-8MF3R7 Operating Instructions Manual Download Page 2

2

z

z

Safety Precautions

 ........................................................... 2

z

z

Precautions for Use

 ......................................................... 4

z

z

Names of Parts

 ................................................................. 5

z

z

Specifications

 ................................................................... 6

• Outdoor unit

 ................................................................... 6

Contents

Thank you for purchasing this Panasonic product.

This product is a commercial air conditioner outdoor unit.

Installation Instructions attached.

Safety Precautions

Product Information

If you have problems or questions 

concerning your Air Conditioner, you will 

need the following information. Model and 

serial numbers are on the nameplate.

Model No. 
Serial No. 
Date of purchase
Dealer’s address
Phone number

Confirm to authorized dealer 

or specialist on usage of 

specified refrigerant type. Using 

of refrigerant other than the 

specified type may cause product 

damage, burst and injury etc.
This air conditioner has no 

ventilator for intaking fresh air 

from outdoors. You must open 

doors or windows frequently 

when you use gas or oil heating 

appliances in the same room, 

which consume a lot of oxygen 

from the air. 

Otherwise there is a risk of 

suffocation in an extreme case.
Never use or store gasoline or 

other flammable vapor or liquid 

near the air conditioner — it is 

very dangerous.
Do not use this appliance in a 

potentially explosive atmosphere.
Never touch the unit with wet hands.
Do not insert your fingers or 

other objects into the air 

conditioner indoor or 

outdoor unit, rotating parts may 

cause injury.

The following symbols used in this 

manual, alert you to potentially dangerous 

conditions to users, service personnel or 

the appliance:

WARNING

This symbol refers to 

a hazard or unsafe 

practice which can result 

in severe personal injury 

or death.

CAUTION

This symbol refers to 

a hazard or unsafe 

practice which can 

result in personal injury 

or product or property 

damage.

Prohibited 

matters

Matters to be  

observed

• Read these Operating Instructions 

carefully before using this air conditioner. If 

you still have any difficulties or problems, 

consult your dealer for help.

• This air conditioner is designed to give 

you comfortable room conditions. Use this 

only for its intended purpose as described 

in these Operating Instructions.

WARNING

Provide a power outlet to be used 

exclusively for each unit, and a 

power supply disconnect, Earth 

Leakage Circuit Breaker (ELCB) 

or Residual Current Device (RCD) 

for overcurrent protection should 

be provided in the exclusive line.
Provide a power outlet 

exclusively for each unit, and full 

disconnection means having a 

contact separation in all poles 

must be incorporated in the fixed 

wiring in accordance with the 

wiring rules.
To prevent possible hazards 

from insulation failure, the 

unit must be grounded.
Do not use modified 

cord, joint cord, 

extension cord or 

unspecified cord to prevent 

overheating and fire. 

OI_300935_EN.indb   2

2018/04/25   10:27:46

Summary of Contents for U-8MF3R7

Page 1: ...upplied with the indoor unit INDOOR UNIT 1 Way Cassette 2 Way Cassette 4 Way Cassette 4 Way Cassette 60 60 Wall Mounted Ceiling Low Silhouette Ducted Slim Low Static Ducted High Static Pressure Ducted Floor Standing Concealed Floor Standing Slim Type Ducted Panasonic Corporation 1006 Kadoma Kadoma City Osaka Japan ACXF55 19200 Before operating the unit read these operating instructions thoroughly ...

Page 2: ... air conditioner indoor or outdoor unit rotating parts may cause injury The following symbols used in this manual alert you to potentially dangerous conditions to users service personnel or the appliance WARNING This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death CAUTION This symbol refers to a hazard or unsafe practice which can result in personal...

Page 3: ...ep the fire alarm and the air outlet at least 1 5m away from the unit Do not cool or heat the room too much if babies or invalids are present Do not turn the air conditioner on and off from the power mains switch Use the ON OFF operation button Do not stick anything into the air outlet of the outdoor unit This is dangerous because the fan is rotating at high speed Do not touch the air inlet or the...

Page 4: ...mean to isolate the air conditioner from the main power supply when not in use for a long time Information for Users on Collection and Disposal of Old Equipment and Used Batteries Information on Disposal in other Countries outside the European Union These symbols are only valid in the European Union If you wish to discard these items please contact your local authorities or dealer and ask for the ...

Page 5: ...Operating Instructions attached to the indoor unit Troubleshooting Refer to the Operating Instructions attached to the indoor unit Optional For all indoor units Wireless Remote Controller Model No CZ RTC4 For all indoor units Timer Remote Controller Model No CZ RTC5B For all indoor units Read the operating instructions included with the Remote Controller High spec Wired Remote Controller Air intak...

Page 6: ...57 0 60 0 61 0 62 0 Sound power level dB A 76 0 78 0 81 0 82 0 82 0 Unit dimensions H W D mm 1842 1180 1000 1842 1180 1000 1842 1180 1000 1842 1180 1000 1842 1180 1000 Net weight kg 264 265 289 337 337 Performance test condition AS NZS 3823 2 Rated conditions Cooling Indoor intake air temp 27 C DB 19 C WB Outdoor intake air temp 35 C DB Heating Indoor intake air temp 20 C DB Outdoor intake air tem...

Page 7: ...7 MEMO OI_300935_EN indb 7 2018 04 25 10 27 48 ...

Page 8: ...Panasonic Corporation Website http www panasonic com Printed in Malaysia Panasonic Corporation 2018 ACXF55 19200 DC0418 0 OI_300935_EN indb 8 2018 04 25 10 27 48 ...