Panasonic U-60PE1R5A Operating Instructions Manual Download Page 5

5

E

NGLISH

Names of Parts 

Air outlet duct *

Air-outlet grille *

Suspension bolt *

Bolt anchor *

Ceiling material *

Indoor unit

Operation Mechanism

 

Heating performance

Since this air conditioner utilizes outside air for heating, 

its heating performance deteriorates as outside tempera-

ture decreases.

(Due to heat pump system)

In that case, use another heating appliance.

 

Defrosting

This appliance may start defrosting operation to melt 

frost formed in the outdoor unit.

Defrosting starts

: The indoor unit fan stops (or the 

speed becomes extremely slow).

”  ” (STANDBY) appears.

Heating operation resumes after several 

minutes

: The indoor unit fan remains stopped (or 

it will run at a very slow speed) until the indoor heat 

exchanger coil warms up suf

fi

 ciently.

 ” ” (STANDBY) is shown.

 

Defrosting is complete

: The indoor unit fan starts 

operation.

 ”  ” (STANDBY) disappears.

INDOOR UNIT

OUTDOOR UNIT

 

‘‘DRY’’ operation

Once the room temperature reaches the level that was 

set, the outdoor unit repeats the cycle of turning on and 

off automatically.

When the outdoor unit is turned off, the indoor unit fan 

will stop, too.

(To prevent the humidity in the room from rising again)

When the room temperature is more likely to reach the 

level that was set, the fan speed is set to ‘‘breeze’’ (light 

wind) automatically.

‘‘DRY’’ operation is not possible if the outdoor tempera-

ture is 15 °C or less.

 

Should the power failure occurs while the 

unit is running

When the unit automatically resumes operation after 

temporary power failure, it uses the same settings before 

the power was cut off.

* Field supplied

Ducted (E1 type)

Air intake

Air intake

Air outlet

Air outlet

PE1

 (60, 71 type) 

PE1

 (100, 125, 140 type)

Model No.

CZ-RWSC3

(For all indoor units)

Model No.

CZ-RTC2

For all indoor 

units

Model No.

CZ-RTC3

For all indoor 

units

Read the operating instructions included 

with the Remote Controller.

Optional

Wireless Remote Controller

Timer Remote Controller

High-spec Wired Remote Controller

00_P07-T11600A_YS0214-0.indb   5

00_P07-T11600A_YS0214-0.indb   5

3/5/2014   2:00:57 PM

3/5/2014   2:00:57 PM

  04/11/2016

Summary of Contents for U-60PE1R5A

Page 1: ...anasonic Corporation 1006 Kadoma Kadoma City Osaka Japan P07 T11600A Ducted E1 type Model No INDOOR UNIT Ducted Type S 60PE1R5A S 71PE1R5A S 100PE1R5A S 125PE1R5A S 140PE1R5A OUTDOOR UNIT Single Split...

Page 2: ...ands Do not insert your fingers or other objects into the air conditioner indoor or outdoor unit rotating parts may cause injury Refrigerant gas leakage may cause fire For safety be sure to turn the a...

Page 3: ...insulation failure the unit must be grounded Do not use modified cord joint cord extension cord or unspecified cord to prevent overheating and fire Stop using the product when any abnormality failure...

Page 4: ...Preparation Turn the power mains on 5 hours before the start of operation For warm up Leave the power mains ON for continuous use ON NOTE Pull off the power plug from a receptacle or switch off the b...

Page 5: ...operation Once the room temperature reaches the level that was set the outdoor unit repeats the cycle of turning on and off automatically When the outdoor unit is turned off the indoor unit fan will s...

Page 6: ...gged with dust Remove the dust The wind speed switch is set to Low Change to High or Strong Improper temperature settings See Tips for Energy Saving The room is exposed to direct sunlight in cooling m...

Page 7: ...ger is dirty Contact your dealer Fog occurs during heating operation Defrost operation is in process The fan is rotating for a while even though operation stops Fan rotation makes operation smooth The...

Page 8: ...ite http panasonic net Printed in China Panasonic Corporation 2014 P07 T11600A YS0214 0 Authorised representative in EU Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15 22525 H...